Measurement of neutron flux parameters for implementation of k0-INAA at Kyoto University Research Reactor

被引:0
|
作者
Mohamed Soliman
Fatma S. Abdou
Van-Doanh Ho
Shun Sekimoto
Koichi Takamiya
Nader M. A. Mohamed
Tsutomu Ohtsuki
机构
[1] Egyptian Atomic Energy Authority,Egypt Second Research Reactor
[2] Egyptian Atomic Energy Authority,Radiation Protection and Civil Defense Department, Nuclear Research Center
[3] Egyptian Atomic Energy Authority,Reactor Physics Department, Reactors Division, Nuclear Research Centre
[4] Center for Nuclear Technologies,Institute for Integrated Radiation and Nuclear Science
[5] Kyoto University,Reactor Department, Nuclear Research Center
[6] Egyptian Atomic Energy Authority,undefined
来源
Journal of Radioanalytical and Nuclear Chemistry | 2022年 / 331卷
关键词
Neutron activation; -INAA; Neutron flux parameters; Fast neutron interference; Kyoto University Research Reactor;
D O I
暂无
中图分类号
学科分类号
摘要
Neutron flux parameters at pneumatic irradiation tube Pn-1 of Kyoto University Research Reactor (KUR) were measured in order to establish k0-INAA method. The measured thermal to epithermal neutron fluxes ratio (f), shape factor of epithermal neutron flux (α), and thermal (ϕth) and fast (ϕf) neutron fluxes were 29.7 ± 2.0, − 0.015 ± 0.003, and (3.17 ± 0.11) × 1012 and (4.79 ± 0.16) × 1011 cm−2 s−1 at 1 MW, respectively. The neutron flux spectrum showed a remarkable stability over the weekly operation cycle as well as at different reactor powers. The analysis results of reference materials [multi-element liquid standard, and Oriental Basma Tobacco Leaves (INCT-OBTL-5)] revealed that the k0-INAA procedure established at the KUR can be regarded as a reliable standardization method of multi-elemental INAA; measured concentrations have zeta-score <  ± 2. Corrections due to nuclear interference resulting from fast neutron reactions must be considered for samples with relatively high concentrations of interfering elements. MCNP5 code was used to estimate the total efficiencies of gamma-rays, which might be required to calculate correction factor for the true coincidence effects.
引用
收藏
页码:3949 / 3956
页数:7
相关论文
共 50 条
  • [21] k0-INAA performance in the measurement of filters sampled in an industry with high loadings of metals
    Almeida, S. M.
    Felix, P. M.
    Franco, C.
    Freitas, M. C.
    Alves, L. C.
    Pinheiro, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (02): : 453 - 455
  • [22] Variation in k0 neutron flux parameters after replacement of the beryllium reflector and graphite wedge at the University of Missouri Research Reactor
    J. D. Brockman
    N. J. Peters
    J. D. Robertson
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 41 - 44
  • [23] Variation in k0 neutron flux parameters after replacement of the beryllium reflector and graphite wedge at the University of Missouri Research Reactor
    Brockman, J. D.
    Peters, N. J.
    Robertson, J. D.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (01) : 41 - 44
  • [24] Reactor power dependency of the neutron flux parameters for k0-standardization
    Instituto Superior de Ciencias y Tecnología Nucleares, Plaza de la Revolución, Ave. Salvador Allende y Luaces, Habana 10600, Cuba
    不详
    J. RADIOANAL. NUCL. CHEM., 1-2 (241-244):
  • [25] Implementation of k 0-standardization method of the INAA at ETRR-2 research reactor
    Soliman, Mohamed
    Mohamed, Nader M. A.
    Gaheen, M. A.
    Saad, E. A.
    Yousef, S. K.
    Sohsah, M. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (02) : 629 - 634
  • [26] Implementation of k0-standardization method of the INAA at ETRR-2 research reactor
    Mohamed Soliman
    Nader M. A. Mohamed
    M. A. Gaheen
    E. A. Saad
    S. K. Yousef
    M. A. Sohsah
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 287 : 629 - 634
  • [27] Effect of control rod insertion on the TRIGA neutron spectrum and the determination of elemental concentrations with k0-INAA
    Lojze Gačnik
    Klemen Ambrožič
    Sebastjan Rupnik
    Vladimir Radulović
    Radojko Jaćimović
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 315 : 711 - 721
  • [28] Effect of control rod insertion on the TRIGA neutron spectrum and the determination of elemental concentrations with k0-INAA
    Gacnik, Lojze
    Ambrozic, Klemen
    Rupnik, Sebastjan
    Radulovic, Vladimir
    Jacimovic, Radojko
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 315 (03) : 711 - 721
  • [29] k0-INAA quality assessment by analysis of soil reference material GBW07401 using the comparator and neutron flux monitor approaches
    Menezes, M. A. B. C.
    Jacimovic, R.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (07) : 1057 - 1063
  • [30] k0-INAA of biological matrices at IPEN neutron activation analysis laboratory, Sao Paulo, using the k0_IAEA software
    Puerta, D. C.
    Figueiredo, A. M. G.
    Semmler, R.
    Jacimovic, R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (02) : 637 - 644