Amperometric Biosensor for Hydrogen Peroxide Based on Direct Electrocatalysis by Hemoglobin Immobilized on Gold Nanoparticles/ 1,6-Diaminohexane Modified Glassy Carbon Electrode

被引:0
|
作者
Mingyu Tang
Shihong Chen
Ruo Yuan
Yaqin Chai
Fengxian Gao
Yi Xie
机构
[1] Southwest University,Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Engineering
来源
Analytical Sciences | 2008年 / 24卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A facile strategy of an amperometric biosensor for hydrogen peroxide based on the direct electrocatalysis of hemoglobin (Hb) immobilized on gold nanoparticles (GNPs)/1,6-diaminohexane (DAH) modified glassy carbon electrode (GCE) has been described. A uniform monolayer film of DAH was initially covalently bound on a GCE surface by virtue of the electrooxidation of one amino group of DAH, and another amino group was modified with GNPs and Hb, successively. The fabrication process was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The proposed biosensor exhibited an effective and fast catalytic response to the reduction of H2O2 with good reproducibility and stability. A linear relationship existed between the catalytic current and the H2O2 concentration in the range of 1.5 × 10-6 to 2.1 × 10-3 M with a correlation coefficient of 0.998 (n = 24). The detection limit (S/N = 3) was 8.8 × 10-7 M.
引用
收藏
页码:487 / 491
页数:4
相关论文
共 50 条
  • [21] Amperometric biosensor for hydrogen Hemoglobin/DNA/Poly-2,6-pyridinediamine peroxide based on modified gold electrode
    Tong, Zhongqiang
    Yuan, Ruo
    Chai, Yaqin
    Chen, Shihong
    Xie, Yi
    THIN SOLID FILMS, 2007, 515 (20-21) : 8054 - 8058
  • [22] A Highly Sensitive Hydrogen Peroxide Biosensor Based on Hemoglobin Immobilized on Cadmium Sulfide Quantum Dots/Chitosan Composite Modified Glassy Carbon Electrode
    Butwong, Nutthaya
    Zhou, Lin
    Moore, Eric
    Srijaranai, Supalax
    Luong, John H. T.
    Glennon, Jeremy D.
    ELECTROANALYSIS, 2014, 26 (11) : 2465 - 2473
  • [23] Electrocatalytic Activity of Silver Nanoparticles Modified Glassy Carbon Electrode as Amperometric Sensor for Hydrogen Peroxide
    Maji, Swarup Kumar
    Dutta, Amit Kumar
    Srivastava, Divesh N.
    Paul, Parimal
    Mondal, Anup
    Adhikary, Bibhutosh
    Adhikary, Utsarga
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (07) : 4969 - 4974
  • [24] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [25] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 911 - 916
  • [26] Amperometric biosensor for hydrogen peroxide and nitrite based on hemoglobin immobilized on one-dimensional gold nanoparticle
    Hong, Jianmin
    Dai, Zhihui
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01): : 222 - 226
  • [27] Hydrogen Peroxide Biosensor based on Carbon Paste Modified Electrode with Hemoglobin and Copper(II) Oxide Nanoparticles
    Abbasi, Amin
    Shamsazar, Ali
    Shamsazar, Fatemeh
    Asadi, Asadollah
    Shamsaldini, Soghra
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (04): : 3986 - 3996
  • [28] Direct electrochemistry of hemoglobin based on Gemini surfactant protected gold nanoparticles modified glassy carbon electrode
    Li, Jinxia
    Zhou, Lihui
    Han, Xia
    Liu, Honglai
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01): : 322 - 326
  • [29] A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode
    Zhang, JD
    Oyama, M
    ELECTROCHIMICA ACTA, 2004, 50 (01) : 85 - 90
  • [30] An amperometric H2O2 biosensor based on hemoglobin nanoparticles immobilized on to a gold electrode
    Narwal, Vinay
    Yadav, Neelam
    Thakur, Manisha
    Pundir, Chandra S.
    BIOSCIENCE REPORTS, 2017, 37