Specific features of the connection of a reflectometer to power transmission lines for location probing

被引:0
|
作者
Minullin R.G. [1 ]
Fardiev I.S. [1 ]
Gubaev D.F. [1 ]
Lukin E.I. [1 ]
机构
[1] Kazan State University of Power Engineering, Kazan
关键词
RUSSIAN Electrical Engineer; Transmission Band; Coupling Capacitor; Overhead Line; Power Transmission Line;
D O I
10.3103/S1068371208020053
中图分类号
学科分类号
摘要
Methods for connecting a reflectometer to a 6-10-or 35-kV energized or deenergized power transmission line are considered. The effect of the parameters of connection filters, coupling capacitors, and choke filters on the parameters of probing pulses is considered. Recommendations regarding selection of the duration of pulses for probing of power transmission lines of distribution grids are made. © 2008 Allerton Press, Inc.
引用
收藏
页码:84 / 91
页数:7
相关论文
共 50 条
  • [21] Magnetic Field Reduction by Optimal Connection for Power Transmission Lines with Underground Power Cables
    Lai, Gordon G.
    Yang, Chien-Feng
    Huang, Hunter M.
    Su, Ching-Tzong
    2009 IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION, VOLS 1-3, 2009, : 801 - +
  • [22] Fault location in power transmission lines using adaptive lifting scheme
    Ji, Z
    Li, HH
    Li, Q
    Wu, QH
    ELECTRONICS LETTERS, 2005, 41 (07) : 440 - 441
  • [23] Comparison of different approaches to arc fault location on power transmission lines
    Pustulka, Mateusz
    Izykowski, Jan
    Lukowicz, Miroslaw
    2013 12TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC 2013), 2013, : 145 - 149
  • [24] Morphological undecimated wavelet decomposition for fault location on power transmission lines
    Zhang, J. F.
    Smith, J. S.
    Wu, Q. H.
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2006, 53 (06) : 1395 - 1402
  • [25] THE USE OF ELECTRIC CURRENTS OF POWER TRANSMISSION-LINES FOR THE EARTH ELECTROMAGNETIC PROBING
    SAPUZHAK, JS
    ENENSTEIN, BS
    DOKLADY AKADEMII NAUK SSSR, 1980, 252 (04): : 838 - 841
  • [26] Fault location in transmission lines
    Lyamets, YY
    IlIn, VA
    Podshivalin, NV
    ELECTRICAL TECHNOLOGY, 1996, (04): : 101 - 112
  • [27] Use of Location Probing to Detect Damage to the Wires of High-Voltage Electric Transmission Lines
    Minullin R.G.
    Power Technology and Engineering, 2017, 51 (4) : 464 - 472
  • [28] Detecting the faults of overhead electric-power lines by the location-probing method
    Minullin R.G.
    Russian Electrical Engineering, 2017, 88 (2) : 61 - 70
  • [29] An averaging method for identification of location probing signals in the high-frequency channel of transmission lines
    R. G. Minullin
    E. I. Lukin
    F. T. Shaikhutdinov
    R. G. Khalilov
    Minullin, R.G., 1600, Allerton Press Incorporation (83): : 30 - 34
  • [30] Detection of cotter pins missing of connection fittings on transmission lines of power system
    Wang, Hongchao
    Shao, Yunfeng
    Zou, Suli
    Ma, Zhongjing
    Zhao, Shuruo
    2021 PROCEEDINGS OF THE 40TH CHINESE CONTROL CONFERENCE (CCC), 2021, : 6873 - 6879