Exergy analysis of direct-expansion solar-assisted heat pumps working with R22 and R433A

被引:0
|
作者
L. Paradeshi
M. Mohanraj
M. Srinivas
S. Jayaraj
机构
[1] National Institute of Technology,Department of Mechanical Engineering
[2] Hindusthan College of Engineering and Technology,Department of Mechanical Engineering
关键词
Direct-expansion solar-assisted heat pumps; R433A; Exergy performance;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, the exergy performance of direct-expansion solar-assisted heat pump systems working with R22 and R433A (mixture of R290 and R1270, 70:30 by mass) was experimentally assessed. The experiments were carried out under the metrological conditions of Calicut in India. (Longitude and latitude of location are 75.78∘E\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$75.78 ^{\circ }\hbox {E}$$\end{document} and 11.25∘N\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$11.25^{\circ }\hbox {N}$$\end{document}, respectively.) The artificial neural network model was developed for simulating the performance of a direct-expansion solar-assisted heat pump system to have realistic performance comparison. The experimental data observed during the year 2016 were used for training and testing the performance of network. The results showed that the network predicted exergy performance of a direct-expansion solar-assisted heat pump was found to be closer to the experimental results with a maximum fraction of absolute variance, minimum root-mean-square values and coefficient of variance. The system exergy destruction of R22 and R433A was found to be 1.36 and 1.25 kW, respectively. Moreover, R433A is identified as an energy-efficient and environmental-friendly alternative to phase out R22 in solar-assisted heat pump systems.
引用
收藏
页码:2223 / 2237
页数:14
相关论文
共 50 条
  • [31] Mass flow rate prediction of direct-expansion solar-assisted heat pump using R290 based on ANN model
    Kong, Xiangqiang
    Ma, Shanle
    Ma, Tingdong
    Li, Ying
    Cong, Xiaochun
    SOLAR ENERGY, 2021, 215 : 375 - 387
  • [32] Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps
    Park, Ki-Jung
    Shim, Yun-Bo
    Jung, Dongsoo
    APPLIED ENERGY, 2008, 85 (09) : 896 - 900
  • [33] Dynamic modeling of an R290 direct-expansion solar-assisted heat pump: Performance analysis for efficient hot water production under different conditions
    Resende, Sara Isabel de Melo
    Diniz, Helio Augusto Goulart
    Machado, Luiz
    de Faria, Ralney Nogueira
    de Oliveira, Raphael Nunes
    JOURNAL OF BUILDING ENGINEERING, 2025, 100
  • [34] A variable frequency control method and experiments of a direct-expansion solar-assisted heat pump system
    Kong, Xiangqiang
    Sun, Penglong
    Jiang, Kailin
    Dong, Shandong
    Li, Ying
    Li, Jianbo
    SOLAR ENERGY, 2018, 176 : 572 - 580
  • [35] Distribution characteristics of refrigerant in microchannel collector/evaporator of direct-expansion solar-assisted heat pump
    Kong X.
    Ma T.
    Ma S.
    Li Y.
    Li J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (08): : 236 - 244
  • [36] TRANSIENT SIMULATION OF A CAPACITY-MODULATED, DIRECT-EXPANSION, SOLAR-ASSISTED HEAT-PUMP
    CHATURVEDI, SK
    ABAZERI, M
    SOLAR ENERGY, 1987, 39 (05) : 421 - 428
  • [37] Performance of a direct-expansion solar-assisted heat pump for domestic hot water production in Algeria
    Benchamma, Sofiane
    Missoum, Mohammed
    Belkacem, Nefissa
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2024, 13 (04): : 572 - 580
  • [38] Experimental validation of a theoretical model for a direct-expansion solar-assisted heat pump applied to heating
    Moreno-Rodriguez, A.
    Garcia-Hernando, N.
    Gonzalez-Gil, A.
    Izquierdo, M.
    ENERGY, 2013, 60 : 242 - 253
  • [39] R134a and various mixtures of R22/R134a as an alternative to R22 in vapour compression heat pumps
    Karagoz, S
    Yilmaz, M
    Comakli, O
    Ozyurt, O
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (02) : 181 - 196
  • [40] The performance comparison of the direct-expansion solar assisted heat pumps with three different PV evaporators
    Song, Zhiying
    Ji, Jie
    Cai, Jingyong
    Li, Zhaomeng
    Yu, Bendong
    ENERGY CONVERSION AND MANAGEMENT, 2020, 213