Numerical modeling for the seismic response of interconnected electrical substation equipment

被引:0
|
作者
Ahmet Güllü
机构
[1] Texas State University,Ingram School of Engineering
来源
关键词
Interconnected electrical equipment; Flexible conductor; Shake table tests; Numerical modeling; Sag-to-span ratio; Bending stiffness;
D O I
暂无
中图分类号
学科分类号
摘要
The seismic safety of electrical substations is significantly important for the resiliency of regions prone to earthquakes since they are one of the main components of the power grids. International standards require an additional amount of slackness and terminal forces in the design of such systems to eliminate the effect of the interconnection of the components. Even though the additional slack might be efficient to reduce the terminal forces, some other issues arise from the point of view of electrical engineering related to the phase-to-ground and minimum safety clearances. In this paper, a simplified numerical model is developed and proposed by using commercial structural analysis packages (SAP2000 and Abaqus/CAE) to reproduce the results of an experimental campaign by considering some other parameters which are generally neglected, i.e., bending stiffness of the conductor and varying damping ratio with the slackness of the conductor. In general, the experimental results (mode shapes and response histories) were captured reasonably by the simplified numerical models. The maximum absolute mean relative differences for the displacements and forces were 13.31% and 14.92%, respectively. Hence, the modeling strategy for the interconnected electrical substation equipment might be employed for further analyses, such as the construction of fragility curves.
引用
收藏
相关论文
共 50 条
  • [41] Quantifying seismic response uncertainty of electrical substation structures using endurance time method
    Baghmisheh, Amir Ghahremani
    Estekanchi, Homayoon E.
    STRUCTURES, 2021, 30 : 838 - 849
  • [42] Seismic performance of UHV composite post electrical equipment interconnected using a rigid bus with a sliding fitting
    He, Chang
    Zhang, Yue
    Xie, Qiang
    Yang, Zhenyu
    EARTHQUAKE SPECTRA, 2022, 38 (03) : 1705 - 1733
  • [43] Overview: on-line monitoring for electrical equipment in substation
    Zhang, Y.L.
    Wang, W.S.
    Xu, D.K.
    Gaoya Dianqi/High Voltage Apparatus, 2001, 37 (05):
  • [44] OIL SPILLS FROM SUBSTATION ELECTRICAL-EQUIPMENT
    不详
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (03): : 925 - 927
  • [45] Seismic response of electrical equipment subjected to high–frequency ground motions
    Singh, Sugandha
    Gupta, Abhinav
    Nuclear Engineering and Design, 2021, 374
  • [46] Seismic response of electrical equipment subjected to high?frequency ground motions
    Singh, Sugandha
    Gupta, Abhinav
    NUCLEAR ENGINEERING AND DESIGN, 2021, 374
  • [47] Guidelines for seismic design of flexible buswork between substation equipment
    Dastous, Jean-Bernard
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2007, 36 (02): : 191 - 208
  • [48] A design method on seismic isolation and reduction of post equipment in substation
    Shi G.
    Xie Q.
    Liu Y.
    Lai W.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (24): : 109 - 116and142
  • [49] Feasibility evaluation of Copula theory for substation equipment with multiple nonlinear-related seismic response indexes
    Wen, Jiayi
    Li, Xiaoxuan
    Xue, Jingwei
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2024, 247
  • [50] Numerical modeling of seismic response of desaturated sandy soils
    Li P.
    Lai J.-Y.
    Chen Y.-M.
    He S.-K.
    Journal of Computational and Theoretical Nanoscience, 2016, 13 (04) : 2449 - 2454