On the construction of a new instrument for cold-neutron prompt gamma-ray activation analysis at the FRM-II

被引:0
|
作者
P. Kudějová
Th. Materna
J. Jolie
A. Türler
P. Wilk
S. Baechler
Zs. Kasztovszky
Zs. Révay
T. Belgya
机构
[1] Nuclear Physics Institute,
[2] University of Cologne,undefined
[3] Nuclear Physics Institute,undefined
[4] University of Cologne,undefined
[5] Nuclear Physics Institute,undefined
[6] University of Cologne,undefined
[7] Institute of Radiochemistry,undefined
[8] Technical University Munich,undefined
[9] Institute of Radiochemistry,undefined
[10] Technical University Munich,undefined
[11] Institut Universitaire de Radiophysique Appliquée,undefined
[12] Department of Nuclear Research,undefined
[13] Institute of Isotopes and Surface Chemistry,undefined
[14] Chemical Research Centre of the HAS,undefined
[15] Department of Nuclear Research,undefined
[16] Institute of Isotopes and Surface Chemistry,undefined
[17] Chemical Research Centre of the HAS,undefined
[18] Department of Nuclear Research,undefined
[19] Institute of Isotopes and Surface Chemistry,undefined
[20] Chemical Research Centre of the HAS,undefined
关键词
Physical Chemistry; Inorganic Chemistry; Systematic Measurement; Good Condition; Test Measurement;
D O I
暂无
中图分类号
学科分类号
摘要
A new flexible prompt gamma-ray activation analysis (PGAA) station will be installed and operated at the FRM-II reactor in Garching at the beginning of the year 2006. The PGAA station has been moved from the Paul Scherrer Institute (PSI), Villigen, Switzerland and is now being re-designed for three different experimental applications: PGAA instrument, cold neutron tomography setup and a compact Ge-array. Simulations of the beam guide have been carried out in order to yield the best conditions for each of the instruments, and are discussed here. A number of the PGAA applications are listed here. A new project dealing with a systematic measurement of bulky composition of small amount of meteorites (~100 mg) is proposed. Results of a test measurement of the Dhurmasala meteorite composition at the PGAA station at the Budapest Research Reactor are presented. Expected parameters of the PGAA facility at FRM-II are compared both with those at PSI and with the Budapest facility.
引用
收藏
页码:221 / 227
页数:6
相关论文
共 50 条
  • [21] Determination of hydrogen in niobium by cold neutron prompt gamma-ray activation analysis and neutron incoherent scattering
    Paul, RL
    Chen-Mayer, HH
    Myneni, GR
    HYDROGEN IN MATERIALS AND VACUUM SYSTEMS, 2003, 671 : 151 - 161
  • [22] COLD NEUTRON-CAPTURE PROMPT GAMMA-RAY ACTIVATION-ANALYSIS AT NIST - AN UPDATE
    PAUL, RL
    LINDSTROM, RM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 42 - ANYL
  • [23] Determination of hydrogen in semiconductors and related materials by cold neutron prompt gamma-ray activation analysis
    Paul, RL
    HYDROGEN IN SEMICONDUCTORS, 2004, 813 : 175 - 179
  • [24] Nondestructive measurement of hydrogen and other elements by cold neutron prompt gamma-ray activation analysis
    Paul, RL
    AMERICAN LABORATORY, 2002, 34 (03) : 15 - +
  • [25] MEASUREMENT OF HYDROGEN BY COLD NEUTRON-CAPTURE PROMPT GAMMA-RAY ACTIVATION-ANALYSIS
    PAUL, RL
    LINDSTROM, RM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 46 - ANYL
  • [26] ANALYSES OF CONSTRUCTION MATERIALS BY NEUTRON-CAPTURE PROMPT GAMMA-RAY ACTIVATION-ANALYSIS
    ANDERSON, DL
    GORDON, GE
    LEPEL, EA
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1983, 61 (04): : 724 - 728
  • [27] NEUTRON-CAPTURE PROMPT GAMMA-RAY ACTIVATION-ANALYSIS AT THE NIST COLD NEUTRON RESEARCH FACILITY
    LINDSTROM, RM
    ZEISLER, R
    VINCENT, DH
    GREENBERG, RR
    STONE, CA
    MACKEY, EA
    ANDERSON, DL
    CLARK, DD
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 167 (01): : 121 - 126
  • [28] PROMPT GAMMA-RAY NEUTRON-ACTIVATION ANALYSIS BY THE ABSOLUTE METHOD
    KHRBISH, YS
    SPYROU, NM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1991, 151 (01): : 55 - 61
  • [29] ANALYTICAL APPLICATIONS OF PROMPT GAMMA-RAY NEUTRON-ACTIVATION ANALYSIS
    GLASCOCK, MD
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 255 - 256
  • [30] Neutron Capture Prompt Gamma-Ray Activation Analysis of Meat Homogenates
    D. L. Anderson
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 244 : 225 - 229