Nondestructive In-situ Permittivity Measurement of Liquid Within a Bottle Using an Open-Ended Microwave Waveguide

被引:0
|
作者
Yuhao Jiang
Yang Ju
Li Yang
机构
[1] Chongqing University,Department of Mechanical Science and Engineering, Graduate School of Engineering
[2] Nagoya University,undefined
来源
关键词
Permittivity; Nondestructive evaluation; Microwave;
D O I
暂无
中图分类号
学科分类号
摘要
This research demonstrates an effective in-situ testing approach to measure permittivity of liquid samples within a container using microwaves. An open-ended waveguide is employed as a sensor in the experiment. This apparatus is easy-to-use because it does not require special calibration and is not limited by sample shape or dimensions. After positioning the bottle inside the open-ended waveguide and adding a layer of surrounding medium that fills the space between waveguide and the bottle, the waveguide functions as a resonant cavity. By analyzing the S11\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$S_{11}$$\end{document} amplitude waveform over the frequency range from 250 to 550 MHz, the resonant frequencies can be obtained for a certain propagating mode. The measured values are found to match the theoretical ones extremely well; this result implies that the new establishment is highly precise and sensitive.
引用
收藏
相关论文
共 50 条
  • [31] Near-Field Microwave Imaging Using Open-Ended Circular Waveguide Probes
    Ramzi, Mohammad R.
    Abou-Khousa, Mohamed
    Prayudi, Iman
    IEEE SENSORS JOURNAL, 2017, 17 (08) : 2359 - 2366
  • [32] Permittivity measurement for rock and ore samples by open-ended coaxial method
    Wu Jun-Jun
    Liu Si-Xin
    Dong Hang
    Zhang Li-Li
    Zeng Zhao-Fa
    Fu Lei
    Wang Fei
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2011, 54 (02): : 457 - 465
  • [33] EM analysis of an open-ended coaxial line used in nondestructive measurement
    Inst of Electronics, Academia Sinica, Beijing, China
    Tien Tzu Hsueh Pao, 8 (116-119):
  • [34] Polymer Curing within an Optimised Open-Ended Microwave Oven
    Sinclair, Keith I.
    Goussetis, George
    Desmulliez, Marc P. Y.
    Sangster, Alan J.
    Tilford, Tim
    Bailey, Chris
    Parrott, Kevin
    2008 EUROPEAN MICROWAVE CONFERENCE, VOLS 1-3, 2008, : 397 - +
  • [35] Design and fabrication of Open-ended Co-axial probe for complex permittivity measurement of liquids using CST Microwave Studio
    Vaja, Chandan R.
    Rana, V. A.
    MATERIALS TODAY-PROCEEDINGS, 2022, 67 : 5 - 11
  • [36] Measurement of complex permittivity of adhesive materials using a short open-ended coaxial line probe
    Abbas, Mahmoud
    Hamdoun, Bassam
    Journal of Microwaves and Optoelectronics, 2004, 3 (06) : 50 - 57
  • [37] Influence of parameters of the flanged open-ended coaxial probe measurement setup on permittivity measurement
    Koselj, Jure
    Bregar, Vladimir B.
    INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 2012, 42 (01): : 36 - 42
  • [38] Permittivity measurements of high conductivity specimens using an open-ended coaxial probe - Measurement limitations
    Klein, K
    JOURNAL OF ENVIRONMENTAL AND ENGINEERING GEOPHYSICS, 2004, 9 (04) : 191 - 200
  • [39] Complex Permittivity Measurement of Artificial Tissue Emulating Material Using Open-Ended Coaxial Probe
    Shim, Jae-Yeon
    Chung, Jae-Young
    IEEE SENSORS JOURNAL, 2020, 20 (09) : 4688 - 4703
  • [40] Combined Thickness and Permittivity Measurement of Thin Layers with Open-Ended Coaxial Probes
    Folgero, Kjetil
    Haukalid, Kjetil
    Kocbach, Jan
    Peterson, Andreas Soto
    SENSORS, 2019, 19 (08)