Splanchnic-cerebral oxygenation ratio (SCOR) values in healthy term infants as measured by near-infrared spectroscopy (NIRS)

被引:0
|
作者
Sean M. Bailey
Karen D. Hendricks-Muñoz
Pradeep Mally
机构
[1] New York University School of Medicine,Department of Pediatrics, Division of Neonatology
[2]  NYU Langone Medical Center/Bellevue Hospital,Department of Pediatrics, Division of Neonatal Medicine
[3] Virginia Commonwealth University School of Medicine,undefined
来源
Pediatric Surgery International | 2013年 / 29卷
关键词
Tissue oxygen saturation; Near-infrared spectroscopy; Neonate; Splanchnic-cerebral oxygenation ratio; Necrotizing enterocolitis;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:591 / 595
页数:4
相关论文
共 50 条
  • [31] Renal Oxygenation Measured by Near-Infrared Spectroscopy in Neonates
    Marin, Terri
    Williams, Bryan L.
    ADVANCES IN NEONATAL CARE, 2021, 21 (04) : 256 - 266
  • [32] NIRS (near-infrared spectroscopy): Use in laparoscopic surgery in infants
    Mena, Margarita
    Selame, Rodrigo
    Cordova, Sebastian
    Araya, Cristopher
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1261 - 1262
  • [33] NEAR-INFRARED SPECTROSCOPY (NIRS) CAN MONITOR REGIONAL TISSUE OXYGENATION
    VALLET, B
    GUERY, B
    MANGALABOYI, J
    CHOPIN, C
    DUPUIS, B
    SCHERPEREEL, P
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 26 - 26
  • [34] The precision of cerebral oxygenation and haemoglobin concentration measurements in neonates measured by near-infrared spectroscopy
    Arri, S. J.
    Biallas, M.
    Haensse, D.
    Fauchère, J. C.
    Bucher, H. U.
    Wolf, M.
    ACTA PAEDIATRICA, 2007, 96 : 154 - 154
  • [35] Cerebral oxygenation measured by near-infrared spectroscopy during circulatory arrest and cardiopulmonary resuscitation
    Nagdyman, N
    Fleck, TPK
    Ewert, P
    Abdul-Khaliq, H
    Redlin, M
    Lange, PE
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (03) : 438 - 442
  • [36] Sensitivity and reliability of cerebral oxygenation responses to postural changes measured with near-infrared spectroscopy
    Arjen Mol
    Jeffrey H. H. Woltering
    Willy N. J. M. Colier
    Andrea B. Maier
    Carel G. M. Meskers
    Richard J. A. van Wezel
    European Journal of Applied Physiology, 2019, 119 : 1117 - 1125
  • [37] Regional Changes in Cerebral Oxygenation Passive Movement Measured by Functional Near-infrared Spectroscopy
    Sugawara, Kazuhiro
    Onishi, Hideaki
    Tsubaki, Atsuhiro
    Takai, Haruna
    Tokunaga, Yuta
    Tamaki, Hiroyuki
    FRONTIERS IN HUMAN NEUROSCIENCE, 2015, 9
  • [38] Sensitivity and reliability of cerebral oxygenation responses to postural changes measured with near-infrared spectroscopy
    Mol, Arjen
    Woltering, Jeffrey H. H.
    Colier, Willy N. J. M.
    Maier, Andrea B.
    Meskers, Carel G. M.
    van Wezel, Richard J. A.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (05) : 1117 - 1125
  • [39] Wavelet Analysis of Cerebral Oxygenation Signal Measured by Near-Infrared Spectroscopy in Moyamoya Disease
    Han, Cong
    Gao, Tian-Xin
    Zhang, Hou-Di
    Ma, Wei
    Li, Yue
    Li, Bin
    Shen, Xu-Xuan
    Wang, Xiao-Peng
    Fu, He-Guan
    Duan, Lian
    Yu, Xin-Guang
    WORLD NEUROSURGERY, 2023, 172 : E12 - E18
  • [40] Effects of incremental exercise on cerebral oxygenation measured by near-infrared spectroscopy: A systematic review
    Rooks, Cherie R.
    Thom, Nathaniel J.
    McCully, Kevin K.
    Dishman, Rod K.
    PROGRESS IN NEUROBIOLOGY, 2010, 92 (02) : 134 - 150