Measurement, analysis and correction of the closed orbit distortion in Indus-2 synchrotron radiation source

被引:0
|
作者
RIYASAT HUSAIN
A D GHODKE
SURENDRA YADAV
A C HOLIKATTI
R P YADAV
P FATNANI
T A PUNTAMBEKAR
P R HANNURKAR
机构
[1] Raja Ramanna Centre for Advanced Technology,
来源
Pramana | 2013年 / 80卷
关键词
Indus-2; storage ring; closed orbit distortion; singular value decomposition; betatron tune; dispersion function; 29.20.−c; 29.27.−a; 41.60.Ap;
D O I
暂无
中图分类号
学科分类号
摘要
The paper presents the measurement, analysis and correction of closed orbit distortion (COD) in Indus-2 at 550 MeV injection energy and 2 GeV synchrotron radiation user run energy. The measured COD was analysed and fitted to understand major sources of errors in terms of the effective quadrupole misalignments. The rms COD was corrected down to less than 0.6 mm in both horizontal and vertical planes. A golden orbit was set for the operating synchrotron radiation beamlines. With COD correction, the injection efficiency at 550 MeV was improved by ~50% and the beam lifetime at 2 GeV was increased by ~8 h. In this paper, the method of global COD correction based on singular value decomposition (SVD) of the orbit response matrix is described. Results for the COD correction in both horizontal and vertical planes at 550 MeV injection energy and at 2 GeV synchrotron radiation user run energy are discussed.
引用
收藏
页码:263 / 275
页数:12
相关论文
共 50 条
  • [1] Measurement, analysis and correction of the closed orbit distortion in Indus-2 synchrotron radiation source
    Husain, Riyasat
    Ghodke, A. D.
    Yadav, Surendra
    Holikatti, A. C.
    Yadav, R. P.
    Fatnani, P.
    Puntambekar, T. A.
    Hannurkar, P. R.
    PRAMANA-JOURNAL OF PHYSICS, 2013, 80 (02): : 263 - 275
  • [2] Measurement of parameters in Indus-2 synchrotron radiation source
    Ghodke, A. D.
    Husain, Riyasat
    Kumar, Pradeep
    Yadav, Surendra
    Puntambekar, T. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [3] Synchrotron radiation source INDUS-2
    Singh, G
    Sahoo, GK
    Angal, D
    Singh, AB
    Ghodke, AD
    Kant, P
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1997, 35 (03) : 183 - 192
  • [4] Indus-2 Synchrotron Radiation Source: current status and utilization
    Deb, S. K.
    Singh, Gurnam
    Gupta, P. D.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [5] Measurement and parametric analysis of transverse coupled bunch instabilities for electron synchrotron radiation source Indus-2
    Yadav, Surendra
    Puntambekar, T. A.
    Varde, P. V.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (10):
  • [6] Failure Analysis of a High Voltage Feedthrough of Indus-2 Synchrotron Radiation Source
    Gupta, R. K.
    Ittoop, M. O.
    Rai, S. K.
    Singh, R.
    Singh, M. K.
    Ganesh, P.
    Kaul, R.
    PRAKTISCHE METALLOGRAPHIE-PRACTICAL METALLOGRAPHY, 2021, 58 (06): : 354 - 375
  • [7] Development of beamline radiation shielding hutch for Indus-2 synchrotron radiation source
    Chouksey, Sanjay
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2012, 50 (11) : 782 - 784
  • [8] Klystron Bias Power Supplies for Indus-2 Synchrotron Radiation Source
    Badapanda, M. K.
    Hannurkar, P. R.
    IETE JOURNAL OF RESEARCH, 2008, 54 (06) : 403 - 413
  • [9] Synchrotron radiation sources INDUS-1 and INDUS-2
    D D Bhawalkar
    G Singh
    R V Nandedkar
    Pramana, 1998, 50 : 467 - 484
  • [10] Synchrotron radiation sources INDUS-1 and INDUS-2
    Bhawalkar, DD
    Singh, G
    Nandedkar, RV
    PRAMANA-JOURNAL OF PHYSICS, 1998, 50 (06): : 467 - 484