4D subject-specific inverse modeling of the chick embryonic heart outflow tract hemodynamics

被引:0
|
作者
Sevan Goenezen
Venkat Keshav Chivukula
Madeline Midgett
Ly Phan
Sandra Rugonyi
机构
[1] Texas A&M University,Department of Mechanical Engineering
[2] Oregon Health and Science University,Department of Biomedical Engineering
关键词
Chick embryonic heart; Outflow tract; Hemodynamics ; cardiac development; Congenital heart disease; Cardiac defects; Inverse methods;
D O I
暂无
中图分类号
学科分类号
摘要
Blood flow plays a critical role in regulating embryonic cardiac growth and development, with altered flow leading to congenital heart disease. Progress in the field, however, is hindered by a lack of quantification of hemodynamic conditions in the developing heart. In this study, we present a methodology to quantify blood flow dynamics in the embryonic heart using subject-specific computational fluid dynamics (CFD) models. While the methodology is general, we focused on a model of the chick embryonic heart outflow tract (OFT), which distally connects the heart to the arterial system, and is the region of origin of many congenital cardiac defects. Using structural and Doppler velocity data collected from optical coherence tomography, we generated 4D (3D+time\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\hbox {3D}\,+\,\hbox {time}$$\end{document}) embryo-specific CFD models of the heart OFT. To replicate the blood flow dynamics over time during the cardiac cycle, we developed an iterative inverse-method optimization algorithm, which determines the CFD model boundary conditions such that differences between computed velocities and measured velocities at one point within the OFT lumen are minimized. Results from our developed CFD model agree with previously measured hemodynamics in the OFT. Further, computed velocities and measured velocities differ by <\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<$$\end{document}15 % at locations that were not used in the optimization, validating the model. The presented methodology can be used in quantifications of embryonic cardiac hemodynamics under normal and altered blood flow conditions, enabling an in-depth quantitative study of how blood flow influences cardiac development.
引用
收藏
页码:723 / 743
页数:20
相关论文
共 50 条
  • [31] Comparison of Immersed Boundary Simulations of Heart Valve Hemodynamics Against In Vitro 4D Flow MRI Data
    Kaiser, Alexander D.
    Schiavone, Nicole K.
    Elkins, Christopher J.
    McElhinney, Doff B.
    Eaton, John K.
    Marsden, Alison L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (10) : 2267 - 2288
  • [32] LOW-ORDER 4D DYNAMICAL MODELING OF HEART MOTION UNDER RESPIRATION
    Madrigal, M. Queralt
    Tadmor, G.
    Cano, G. Crosas
    Brooks, D. H.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1326 - 1329
  • [33] In vivo functional imaging of blood flow and wall strain rate in outflow tract of embryonic chick heart using ultrafast spectral domain optical coherence tomography
    Li, Peng
    Yin, Xin
    Shi, Liang
    Rugonyi, Sandra
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (09)
  • [34] Subject-specific finite-element modeling of normal aortic valve biomechanics from 3D+t TEE images
    Labrosse, Michel R.
    Beller, Carsten J.
    Boodhwani, Munir
    Hudson, Christopher
    Sohmer, Benjamin
    MEDICAL IMAGE ANALYSIS, 2015, 20 (01) : 162 - 172
  • [35] Physics-based Patient-Specific Respiration Modeling for 4D Treatment Planning
    Shi, C.
    Eom, J.
    Vines, D.
    De, S.
    Xu, G. X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S649 - S649
  • [36] Measurement and modeling of 4D live mouse heart volumes from CT time series
    Wetzel, Arthur W.
    Badea, Cristian T.
    Pomerantz, Stuart M.
    Mistry, Nilesh
    Nave, Demian
    Johnson, Allan
    VIDEOMETRICS IX, 2007, 6491
  • [37] Neopulmonary Outflow Tract Obstruction Assessment by 4D Flow MRI in Adults With Transposition of the Great Arteries After Arterial Switch Operation
    Belhadjer, Zahra
    Soulat, Gilles
    Ladouceur, Magalie
    Pitocco, Francesca
    Legendre, Antoine
    Bonnet, Damien
    Iserin, Laurence
    Mousseaux, Elie
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (06) : 1699 - 1705
  • [38] 4D flow magnetic resonance imaging to assess right ventricular outflow tract in patients undergoing transcatheter pulmonary valve replacement
    Karsenty, Clement
    Alattar, Yousef
    Mousseaux, Elie
    Marcilhacy, Gabrielle
    Gencer, Umit
    Craiem, Damian
    Iserin, Laurence
    Ladouceur, Magalie
    Legendre, Antoine
    Laredo, Mikael
    Bonnet, Damien
    Malekzadeh-Milani, Sophie
    Soulat, Gilles
    REVISTA ESPANOLA DE CARDIOLOGIA, 2023, 76 (10): : 793 - 802
  • [39] Specific inhibition of HCN channels slows rhythm differently in atria, ventricle and outflow tract and stabilizes conduction in the anoxic-reoxygenated embryonic heart model
    Sarre, Alexandre
    Pedretti, Sarah
    Gardier, Stephany
    Raddatz, Eric
    PHARMACOLOGICAL RESEARCH, 2010, 61 (01) : 85 - 91
  • [40] Patient-specific Hemodynamics of Severe Carotid Artery Stenosis Before and After Endarterectomy Examined by 4D Flow MRI
    Ko, Seungbin
    Lee, Jeesoo
    Song, Simon
    Kim, Doosang
    Lee, Sang Hyung
    Cho, Jee-Hyun
    SCIENTIFIC REPORTS, 2019, 9 (1)