Sample preparation procedure for PIXE elemental analysis on soft tissues

被引:0
|
作者
B. Kubica
W. M. Kwiatek
E. M. Dutkiewicz
M. Lekka
机构
[1] Institute of Nuclear Physics,
关键词
Soft Tissue; Water Sample; Sample Preparation; Elemental Content; Preparation Procedure;
D O I
暂无
中图分类号
学科分类号
摘要
Trace element analysis is one of the most important field in analytical chemistry. There are several instrumental techniques which are applied for determinations of microscopic elemental content. The PIXE (Proton Induced X-ray Emission) technique is one of the nuclear techniques that is commonly applied for such purpose due to its multielemental analysis possibilities. The aim of this study was to establish the optimal conditions for target preparation procedure. In this paper two different approaches to the topic are presented and widely discussed.1,2 The first approach was the traditional pellet technique and the second one was mineralization procedure. For the analysis soft tissue such as liver was used. Some results are also presented on water samples
引用
收藏
页码:247 / 249
页数:2
相关论文
共 50 条
  • [31] SPECIMEN PREPARATION IN PIXE ANALYSIS
    CAMPBELL, JL
    NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (1-2): : 263 - 273
  • [32] Target preparation procedure and PIXE analysis of selenium in different foods consumed in the region of Algiers
    Amokrane, A
    Benamar, MEA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (01): : 50 - 53
  • [33] PIXE setup for liquid sample analysis
    Kral, J
    Voltr, J
    Nejedly, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 109 : 167 - 169
  • [34] SAMPLE PREPARATION METHODS OF TREE-RINGS FOR PIXE-PIGE MULTIELEMENTAL ANALYSIS
    HALL, GS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 60 - 64
  • [35] COMPARISON OF DIFFERENT SAMPLE AND TARGET PREPARATION PROCEDURES FOR PIXE ANALYSIS OF BIOLOGICAL-MATERIALS
    MAENHAUT, W
    DEREU, L
    VANDENHAUTE, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3): : 135 - 140
  • [36] Ultrasonic extraction as a sample preparation technique for elemental analysis by atomic spectrometry
    Ashley, K
    Andrews, RN
    Cavazos, L
    Demange, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (10) : 1147 - 1153
  • [37] SAMPLE PREPARATION BY COLUMN ELUTION FOR ELEMENTAL ANALYSIS OF PLANT-TISSUE
    GAINES, TP
    MITCHELL, GA
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1978, 61 (05): : 1179 - 1182
  • [38] QUANTITATIVE PIXE ANALYSIS OF BIOMEDICAL MATERIAL - SAMPLE PREPARATION, IRRADIATION AND QUALITY-CONTROL
    MALMQVIST, KG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 183 - 190
  • [39] Comparative trace elemental analysis of cancerous and non-cancerous tissues of rectal cancer patients using PIXE
    Raju, G. J. Naga
    Sarita, P.
    Murthy, K. S. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2017, 404 : 146 - 149
  • [40] Procedure for Modelling of Soft Tissues Behavior
    Franulovic, M.
    Markovic, K.
    Pilicic, S.
    2017 40TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2017, : 608 - 612