Automated left heart chamber volumetric assessment using three-dimensional echocardiography in Chinese adolescents

被引:13
|
作者
Luo X.-X. [1 ,2 ]
Fang F. [3 ]
So H.-K. [4 ]
Liu C. [2 ]
Yam M.-C. [4 ]
Lee A.P.-W. [2 ]
机构
[1] Department of Ultrasonography, Shenzhen Hospital, Southern Medical University, Shenzhen
[2] Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Faculty of Medicine, Chinese University of Hong Kong
[3] Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing Anzhen Hospital, Capital Medical University, Beijing
[4] Department of Pediatrics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong
来源
Echo Research & Practice | 2017年 / 4卷 / 4期
关键词
Adolescents; Automation; Cardiac chamber quantification; HeartModel; Three-dimensional echocardiography;
D O I
10.1530/ERP-17-0028
中图分类号
学科分类号
摘要
Background: Several studies have reported the accuracy and reproducibility of HeartModel for automated determination of three-dimensional echocardiography (3DE)-derived left heart volumes and left ventricular (LV) ejection fraction (LVEF) in adult patients. However, it remains unclear whether this automated adaptive analytics algorithm, derived from a ‘training’ population, can encompass adequate echo images in Chinese adolescents. Objectives: The aim of our study was to explore the accuracy of HeartModel in adolescents compared with expert manual three-dimensional (3D) echocardiography. Methods: Fifty-three Chinese adolescent subjects with or without heart disease underwent 3D echocardiographic imaging with an EPIQ system (Philips). 3D cardiac volumes and LVEF obtained with the automated HeartModel program were compared with manual 3D echocardiographic measurements by an experienced echocardiographer. Results: There was strong correlation between HeartModel and expert manual 3DE measurements (r=0.875–0.965, all P<0.001). Automated LV and left atrial (LA) volumes were slightly overestimated when compared to expert manual measurements, while LVEF showed no significant differences from the manual method. Importantly, the intra- and inter-observer variability of automated 3D echocardiographic model was relatively low (<1%), surpassing the manual approach (3.5–17.4%), yet requiring significantly less analyzing time (20±7 vs 177±30s, P<0.001). Conclusion: Simultaneous quantification of left heart volumes and LVEF with the automated HeartModel program is rapid, accurate and reproducible in Chinese adolescent cohort. Therefore, it has a potential to bring 3D echocardiographic assessment of left heart chamber volumes and function into busy pediatric practice. © 2017 The authors.
引用
收藏
页码:53 / 61
页数:8
相关论文
共 50 条
  • [21] Assessment of the left atrial appendage using transthoracic real-time three-dimensional echocardiography
    Shteerman, E
    Hirata, K
    Kapoor, O
    Desvarieux, MEN
    Pulerwitz, T
    Fall, K
    Wanstall, FK
    Di Tullio, MR
    Homma, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 345A - 345A
  • [22] Functional Assessment of Donor and Recipient Left Atrium in Heart Transplant Patients Using Full-Volume Three-Dimensional Echocardiography
    Ahmad, Saad
    Bhatti, Sabha
    Shizukuda, Yukitaka
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (02): : 191 - 195
  • [23] Characterizing the normal heart using quantitative three-dimensional echocardiography
    Clark, T. J.
    Sheehan, F. H.
    Bolson, E. L.
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (06) : 467 - 508
  • [24] Intraoperative Three-Dimensional Versus Two- Dimensional Echocardiography for Left Ventricular Assessment
    Meris, Alessandra
    Santambrogio, Luisa
    Casso, Gabriele
    Mauri, Romano
    Engeler, Albin
    Cassina, Tiziano
    ANESTHESIA AND ANALGESIA, 2014, 118 (04): : 711 - 720
  • [25] Real-time three-dimensional echocardiography in assessment of heart disease
    Ahmad, M
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (01): : 73 - 77
  • [26] Three-dimensional echocardiography: In vitro validation of left and right heart cavity volumes
    Pini, R
    Giannazzo, G
    DiBari, M
    Innocenti, F
    Masotti, L
    Devereux, RB
    ACOUSTICAL IMAGING, VOL 22, 1996, 22 : 263 - 266
  • [27] Volumetric analysis of the right and left ventricle in a porcine heart model: Comparison of three-dimensional echocardiography, magnetic resonance imaging and angiocardiography
    Department of Paediatric Cardiology, Heinrich-Heine-Univ., M., Düsseldorf, Germany
    不详
    不详
    Eur. J. Ultrasound, 3 (245-255):
  • [28] Automated Three-Dimensional Reconstruction of the Left Ventricle From Multiple-Axis Echocardiography
    Rajan, Navaneetha Krishnan
    Song, Zeying
    Hoffmann, Kenneth R.
    Belohlavek, Marek
    McMahon, Eileen M.
    Borazjani, Iman
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (01):
  • [29] Use of Three-Dimensional Speckle-Tracking Echocardiography for Quantitative Assessment of Global Left Ventricular Function: A Comparative Study to Three-Dimensional Echocardiography
    Luis, Sushil A.
    Yamada, Akira
    Khandheria, Bijoy K.
    Speranza, Vicki
    Benjamin, Anthony
    Ischenko, Matthew
    Platts, David G.
    Hamilton-Craig, Christian R.
    Haseler, Luke
    Burstow, Darryl
    Chan, Jonathan
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (03) : 285 - 291
  • [30] Evaluation of left ventricular myocardial mechanics and synchrony in heart transplant patients using three-dimensional echocardiography
    Assabiny, A.
    Kosztin, A.
    Farkas, B.
    Tokodi, M.
    Szelenyi, Z. S.
    Hajas, A.
    Takacs, P.
    Sax, B.
    Merkely, B.
    Kovacs, A.
    EUROPEAN HEART JOURNAL, 2015, 36 : 318 - 318