Marginal integrity of low-shrinking versus methacrylate-based composite: effect of different one-step self-etch adhesives

被引:0
|
作者
Ladislav Gregor
Lefever Dorien
Tissiana Bortolotto
Albert J. Feilzer
Ivo Krejci
机构
[1] University of Geneva,Division of Cariology and Endodontology, School of Dentistry
[2] University of Amsterdam and VU University Amsterdam,Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA)
[3] University of Geneva,Division of Cariology and Endodontology and President, School of Dentistry
来源
Odontology | 2017年 / 105卷
关键词
Marginal adaptation; Silorane; One-step self-etch; Adhesive system; Low-shrinking composite;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of the study was to evaluate the influence of composite type and adhesive system on the quality of marginal adaptation in standardized Class V cavities before and after thermo-mechanical loading (TML). The cavities were restored using different combinations of three adhesive systems [(Silorane System Adhesive (SSA), Clearfil S3 Bond (S3), G-Bond (G-B)] and two resin composite materials (Filtek Silorane, Clearfil AP-X). Six groups (n = 10): Group A (SSA-Primer + SSA-Bond, Filtek Silorane), Group B (SSA-Primer + SSA-Bond, Clearfil AP-X), Group C (S3 + SSA-Bond, Filtek Silorane), Group D (S3 + SSA-Bond, Clearfil AP-X), Group E (G-B + SSA-Bond, Filtek Silorane) and Group F (G-B + SSA-Bond, Clearfil AP-X) were defined. Marginal adaptation was assessed on replicas in the SEM at 200 × magnification before and after TML (3000 × 5–55 °C, 1.2 106 × 49 N; 1.7 Hz) under simulated dentinal fluid. The highest scores of continuous margins (%CM) were observed in the group F (G-B + SSA-Bond, Clearfil AP-X: before loading 96.4 (±3.2)/after loading 90.8 (±7.0)). A significant effect of adhesive system, composite type and loading interval was observed on the results (p < 0.05). Significantly lower scores of %CM were observed for silorane-based composite (Filtek Silorane) after TML in comparison with methacrylate-based composite (Clearfil AP-X) considering total marginal length (p < 0.05). For both Filtek Silorane and Clearfil AP-X, G-Bond performed significantly better than SSA-Primer and Clearfil S3 Bond (p < 0.05). For all combinations of one-step self-etch adhesives and SSA-Bond resin coating, silorane-based low-shrinking composite exhibited inferior marginal adaptation than did the methacrylate-based composite.
引用
收藏
页码:291 / 299
页数:8
相关论文
共 50 条
  • [21] Marginal microleakage of class V resin-based composite restorations bonded with six one-step self-etch systems
    Sanchez-Ayala, Alfonso
    Farias-Neto, Arcelino
    Reis Vilanova, Larissa Soares
    Gomes, Joao Carlos
    Mongruel Gomes, Osnara Maria
    BRAZILIAN ORAL RESEARCH, 2013, 27 (03): : 225 - 230
  • [22] Conversion of one-step to two-step self-etch adhesives for improved efficacy and extended application
    King, NM
    Tay, FR
    Pashley, DH
    Hashimoto, M
    Ito, S
    Brackett, WW
    García-Godoy, F
    Sunico, M
    AMERICAN JOURNAL OF DENTISTRY, 2005, 18 (02): : 126 - 134
  • [23] Effects of Storage Temperature on the Shelf Life of One-step and Two-step Self-etch Adhesives
    Ma, S.
    Fujita , K.
    Nishiyama, N.
    OPERATIVE DENTISTRY, 2009, 34 (04) : 472 - 480
  • [24] NaOCl degradation of one-step one-bottle self-etch adhesives bonded to bovine dentine
    Yildirim, Tahsin
    Ayar, Muhammet Kerim
    Yesilyurt, Cemal
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2016, 30 (02) : 210 - 217
  • [25] Smear layer-deproteinizing improves bonding of one-step self-etch adhesives to dentin
    Thanatvarakorn, Ornnicha
    Prasansuttiporn, Taweesak
    Thittaweerat, Suppason
    Foxton, Richard M.
    Ichinose, Shizuko
    Tagami, Junji
    Hosaka, Keiichi
    Nakajima, Masatoshi
    DENTAL MATERIALS, 2018, 34 (03) : 434 - 441
  • [26] Resistance to Degradation of Resin-Dentin Bonds Produced by One-Step Self-Etch Adhesives
    Toledano, Manuel
    Cabello, Inmaculada
    Yamauti, Monica
    Giannini, Marcelo
    Aguilera, Fatima S.
    Osorio, Estrella
    Osorio, Raquel
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (06) : 1480 - 1493
  • [27] Effect of Postoperative Peroxide Bleaching on the Marginal Seal of Composite Restorations Bonded With Self-etch Adhesives
    Roubickova, A.
    Dudek, M.
    Comba, L.
    Housova, D.
    Bradna, P.
    OPERATIVE DENTISTRY, 2013, 38 (06) : 644 - 654
  • [28] Effect of a one-step self-etch adhesive on endogenous dentin matrix metalloproteinases
    Apolonio, Fabianni M.
    Mazzoni, Annalisa
    Angeloni, Valeria
    Scaffa, Polliana M. C.
    Santi, Spartaco
    Saboia, Vicente de Paulo A.
    Tay, Franklin R.
    Pashley, David H.
    Breschi, Lorenzo
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2017, 125 (02) : 168 - 172
  • [29] Effect of solvent evaporation strategies on regional bond strength of one-step self-etch adhesives to root canal dentine
    Thitthaweerat, S.
    Nakajima, M.
    Foxton, R. M.
    Tagami, J.
    INTERNATIONAL ENDODONTIC JOURNAL, 2013, 46 (11) : 1023 - 1031
  • [30] Effect of 3-year water storage on the performance of one-step self-etch adhesives applied actively on dentine
    Loguercio, Alessandro Dourado
    Stanislawczuk, Rodrigo
    Mena-Serrano, Alexandra
    Reis, Alessandra
    JOURNAL OF DENTISTRY, 2011, 39 (08) : 578 - 587