Peculiarities of Measurements of AC Traction Current Asymmetry in Rail Lines

被引:5
|
作者
Shamanov V.I. [1 ]
机构
[1] Moscow State University of Railway Engineering (MIIT), Moscow
关键词
automatic locomotive signaling; measurements; rail circuits; rail lines; traction current asymmetry; traction current in rails;
D O I
10.3103/S1068371218090122
中图分类号
学科分类号
摘要
Abstract: Up to half of failures in the operation of rail circuits and automatic locomotive signaling at the sections of railways with ac electric traction occurs due to the disturbances caused by the traction current asymmetry in the rail lines. Since the primary source of this asymmetry is the asymmetry of resistances of rail threads within the rail circuits, the measurements of the resistance of elements of each rail thread make it possible to not only define the traction current asymmetry, but also to find the elements, the resistances of which go beyond the limits of the norm. The traction current asymmetry can also be measured directly; however, the measurement results depend as well on the conditions of their being carried out—on the temperature of rails and the magnitude of alternating traction current in them. This is explained by the fact that the asymmetry of resistances of rail threads of rail line is formed owing to an asymmetric increase in them in the transient electrical resistances in the joints of rail links and in the choke bridges. These transient resistances depend on ambient temperature and traction currents in rail threads slightly. As a result, when decreasing the temperature of the rails of P65 type from +40 to –40°C, the asymmetry of resistances of rail threads taking into account their mutual inductance increases by 2.2—2.4 times, while increasing the traction current in rails, for example, by three times causes almost the same asymmetry increase. The influence of mutual inductance of rail threads with the contact wire leads to a decrease in the traction current asymmetry in the rail line. The mutual inductance of rail threads with high-voltage lines of longitudinal power supply that are placed on the contact line supports can increase or decrease this asymmetry, depending on which of the rail threads has less resistance. All these factors should be taken into account both when measuring the asymmetry of resistances of rail threads or the asymmetry of alternating traction current in them and when extrapolating these data to other operating conditions of the rail traction network by the rail temperature or by the magnitude of currents in rail threads, contact wires, and high-voltage lines. © 2018, Allerton Press, Inc.
引用
收藏
页码:536 / 539
页数:3
相关论文
共 50 条
  • [31] Review of the AC Overhead Wires, the DC Third Rail and the DC Fourth Rail Transit Lines: Issues and Challenges
    Abd Rahman, Farah Asyikin
    Ab Kadir, Mohd Zainal Abidin
    Osman, Miszaina
    Amirulddin, Ungku Anisa Ungku
    IEEE ACCESS, 2020, 8 : 213277 - 213295
  • [32] Generalized automatic system for AC/DC transfer, AC voltage, and AC current measurements
    Pogliano, Umberto
    Bosco, Gian Carlo
    Lanzillotti, Marco
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (05) : 1747 - 1751
  • [33] A current mode detector array for γ-ray asymmetry measurements
    Gericke, MT
    Blessinger, C
    Bowman, JD
    Gillis, RC
    Hartfield, J
    Ino, T
    Leuschner, M
    Masuda, Y
    Mitchell, GS
    Muto, S
    Nann, H
    Page, SA
    Penttilä, SI
    Ramsay, WD
    Seo, PN
    Snow, WM
    Tasson, J
    Wilburn, WS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 540 (2-3): : 328 - 347
  • [34] Common Mode Current Measurements in Traction Systems for Electric Vehicles
    Widek, Per
    Alakula, Mats
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (02) : 2061 - 2068
  • [35] Calculation of Urban Rail AC/DC Power Supply with Traction Substation in Multi-Operation Modes
    Liu W.
    Zhang Y.
    Zhang J.
    Li K.
    Li Q.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2020, 55 (06): : 1163 - 1170
  • [36] Analysis of Rail Potential Characteristics of AC/DC Dual-system Traction Power Supply System
    Chen M.
    Fu H.
    Xie C.
    Liu W.
    Xu W.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2022, 57 (04): : 729 - 736
  • [37] Evaluation of Rail Potential and Stray Current With Dynamic Traction Networks in Multitrain Subway Systems
    Du, Guifu
    Wang, Jun
    Jiang, Xingxing
    Zhang, Dongliang
    Yang, Longyue
    Hu, Yihua
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2020, 6 (02) : 784 - 796
  • [38] General layout of the electrical calculation of contact lines for alternating current traction
    Guidi Buffarini, Giuseppe
    Ingegneria Ferroviaria, 2011, 66 (12): : 1125 - 1134
  • [39] Comparison of Locomotive Drives Using Current Forced ac Traction Motors.
    McLean, G.W.
    1984, (77):
  • [40] Sensitivity of the Model of Traction Current Distribution in Rails to Variability in Impedances and Admittances of the Rail Network
    Havryliuk, Volodymyr