Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Olive and Refined Pomace Olive Oils with Modified Low Temperature and Ultrasound-Assisted Liquid–Liquid Extraction Method Followed by the HPLC/FLD

被引:4
|
作者
Zohreh Taghvaee
Zahra Piravivanak
Karamatollah Rezaei
Mohammad Faraji
机构
[1] Standard Research Institute (SRI),Faculty of Food Industry and Agriculture, Department of Food Science and Technology
[2] University of Tehran,Department of Food Science, Engineering and Technology
来源
Food Analytical Methods | 2016年 / 9卷
关键词
Polycyclic aromatic hydrocarbons; Olive oil; Refined pomace olive oil; Low temperature cleanup; Ultrasound-assisted liquid–liquid extraction cleanup; High-performance liquid chromatography with fluorescence detection (HPLC/FLD);
D O I
暂无
中图分类号
学科分类号
摘要
The cleanup method of modified low temperature was compared with the standardized method of modified ultrasound-assisted liquid–liquid (UALL) extraction for the analysis of 15 polycyclic aromatic hydrocarbons (PAHs) in olive oil and refined pomace olive oil. The modified UALL extraction consisted in purification on C18 reversed-phase, Florisil-bonded-phase and NH2 cartridges, and modified low-temperature extraction was followed by alumina-N and NH2 solid-phase extraction (SPE) cartridges. Both methods are followed by reversed-phase high-performance liquid chromatography with fluorescence detection. The chromatograms of the final extracts showed lower interferences in both of the methods. The solvent consumption and cost for the modified UALL method were higher than those of the modified low temperature, and also, it needed more equipment, but its analysis time was less. The limit of detection and limit of quantitation of the modified UALL method were 0.16–0.97 and 0.57–2.93 μg kg−1, respectively, and for the modified low temperature, they were 0.09–1.97 and 0.29–5.99 μg kg−1, respectively. The PAH recoveries for the modified UALL extraction method ranged from 75.0 to 111.0 % (RSD = 3–8 %), and for the modified low temperature, they ranged from 81.5 to 113.8 % (RSD = 3–10 %).
引用
收藏
页码:1220 / 1227
页数:7
相关论文
共 40 条
  • [21] Low-temperature cleanup with solid-phase extraction for the determination of polycyclic aromatic hydrocarbons in edible oils by reversed phase liquid chromatography with fluorescence detection
    Payanan, Thongsuk
    Leepipatpiboon, Natchanun
    Varanusupakul, Puttaruksa
    FOOD CHEMISTRY, 2013, 141 (03) : 2720 - 2726
  • [22] Application of thermal ultrasound-assisted liquid-liquid micro-extraction coupled with HPLC-UV for rapid determination of synthetic phenolic antioxidants in edible oils
    Abedi, Abdol-Samad
    Hemmati, Fatemeh
    Abedini, Amir Hossein
    Mohammadi, Abdorreza
    Moslemi, Masoumeh
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2021, 98 (10) : 969 - 978
  • [23] Microwave-assisted extraction and dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry for isolation and determination of polycyclic aromatic hydrocarbons in smoked fish
    Ghasemzadeh-Mohammadi, Vahid
    Mohammadi, Abdorreza
    Hashemi, Maryam
    Khaksar, Ramin
    Haratian, Parivash
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1237 : 30 - 36
  • [24] One-step solvent extraction followed by liquid chromatography–atmospheric pressure photoionization tandem mass spectrometry for the determination of polycyclic aromatic hydrocarbons in edible oils
    Long-Kai Shi
    Yu-Lan Liu
    Hua-Min Liu
    Ming-Ming Zhang
    Analytical and Bioanalytical Chemistry, 2015, 407 : 3605 - 3616
  • [25] Simultaneous extraction and analysis of antibiotics, pesticides and polycyclic aromatic hydrocarbons in honey by freezing-assisted micro sugaring-out liquid-liquid extraction combined with LC-MS/MS and HPLC-FLD
    Fei, Zhixin
    Bao, Yun
    Zhao, Guiying
    Bi, Zenghui
    Liu, Yang
    Song, Qing
    Gao, Jie
    MICROCHEMICAL JOURNAL, 2025, 209
  • [26] One-step solvent extraction followed by liquid chromatography-atmospheric pressure photoionization tandem mass spectrometry for the determination of polycyclic aromatic hydrocarbons in edible oils
    Shi, Long-Kai
    Liu, Yu-Lan
    Liu, Hua-Min
    Zhang, Ming-Ming
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (13) : 3605 - 3616
  • [27] Determination of polycyclic aromatic hydrocarbons (PAH4) in licorice root (Glycyrrhiza uralensis Fisch.) using dispersive solid-liquid extraction coupled with HPLC-FLD
    Cho, Yun-Jin
    Nam, Tae Gyu
    FOOD SCIENCE AND BIOTECHNOLOGY, 2025,
  • [28] DETERMINATION OF TRIAZINE HERBICIDES IN SOIL SAMPLES BY ULTRASOUND-ASSISTED EXTRACTION FOLLOWED BY DISPERSIVE LIQUID-LIQUID MICROEXTRACTION BASED ON SOLIDIFICATION OF FLOATING ORGANIC DROPLET AND HPLC-UV ANALYSIS
    Dragus, Andreea
    Beldean-Galea, Mihail Simion
    Coman, Virginia
    REVUE ROUMAINE DE CHIMIE, 2014, 59 (11-12) : 1029 - 1036
  • [29] Determination of Polycyclic Aromatic Hydrocarbons in Edible Oil Using Fast and Sensitive Microwave-assisted Extraction and Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Mass Spectrometry
    Mohammadi, Abdorreza
    Malek-Mohammadi Jahani, Simin
    Kamankesh, Marzieh
    Jazaeri, Sahar
    Eivani, Mohammadjavad
    Esmaeili, Saeideh
    Abdi, Sajad
    POLYCYCLIC AROMATIC COMPOUNDS, 2020, 40 (03) : 705 - 713
  • [30] A Method to Determination of Lead Ions in Aqueous Samples: Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction Method Based on Solidification of Floating Organic Drop and Back-Extraction Followed by FAAS
    Arpa, Cigdem
    Aridasir, Itir
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2018, 2018