Monte Carlo study of conversion factors for ionization chamber dosimetry in solid slab phantoms for MV photon beams

被引:0
|
作者
Dong-wook Park
Jai-ki Lee
机构
[1] Hanyang University,Department of Nuclear Engineering
[2] Ilsan Paik Hospital,Department of Radiation Oncology
来源
关键词
Monte Carlo; Solid phantom; RW3; Ion chamber; FC65-G;
D O I
暂无
中图分类号
学科分类号
摘要
For high energy photon beams, solid phantom to water dose conversion factors were calculated by using a Monte Carlo method, and the result were compared with measurements and published data. Based on the absorbed dose to water dosimetry protocol, the conversion factor was theoretically divided into stopping powers ratios, perturbation factors and ratios of absorbed dose to water and that to solid phantom. Data for a Farmer-type chamber and a solid phantom based on polystyrene which is one of the most common material were applied to calculate the conversion factors for 6 MV and 15 MV photon beams. All measurements were conducted after 10 Gy pre-irradiation and thermal equilibrium had been established with solid slabs in a treatment room. The calculated and the measured conversion factors were in good agreement and could be used to confirm the feasibility of the solid phantom as a substitute for water for high energy photon beam.
引用
收藏
页码:647 / 652
页数:5
相关论文
共 50 条
  • [21] Experimental and Monte-Carlo characterization of the novel compact ionization chamber PTW 31023 for reference and relative dosimetry in high energy photon beams
    Buesing, Isabel
    Brant, Andre
    Lange, Tobias
    Delfs, Bjoern
    Poppinga, Daniela
    Kranzer, Rafael
    Looe, Hui Khee
    Poppe, Bjoern
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (04): : 303 - 313
  • [22] Beam quality conversion factors for parallel-plate ionization chambers in MV photon beams
    Muir, B. R.
    McEwen, M. R.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2012, 39 (03) : 1618 - 1631
  • [23] Monte Carlo-derived ionization chamber correction factors in therapeutic carbon ion beams
    Khan, Ahtesham Ullah
    Simiele, Eric A.
    DeWerd, Larry A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (19):
  • [24] Monte-Carlo determination of output correction factors for four detectors in small MV photon beams
    Valdes Santurio, G.
    Alfonso Laguardia, R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S698 - S698
  • [25] A Monte Carlo study of backscatter in the monitor ion chamber for clinical photon and electron beams
    Verhaegen, F
    Symonds-Tayler, R
    Mubata, C
    Bidmead, M
    Nahum, A
    Liu, HH
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 466 - 468
  • [26] Monte Carlo simulation of 10 MV photon beams and beam profile validations
    Tartar, Ahmet
    MEASUREMENT, 2013, 46 (09) : 3026 - 3031
  • [27] PERIPHERAL DOSIMETRY BY MONTE CARLO FOR 6MV AND CO-60 BEAMS
    Joosten, A.
    Levi, F.
    Baechler, S.
    Mirimanoff, R. O.
    Bochud, F.
    Moeckli, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 (09) : 636 - 636
  • [28] A Monte Carlo study of infinitely long phantoms used for CT dosimetry
    Abuhaimed, A.
    Martin, C. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S760 - S760
  • [29] PRIMO Monte Carlo software benchmarked against a reference dosimetry dataset for 6 MV photon beams from Varian linacs
    Marcelino Hermida–López
    David Sánchez–Artuñedo
    Juan Francisco Calvo–Ortega
    Radiation Oncology, 13
  • [30] PRIMO Monte Carlo software benchmarked against a reference dosimetry dataset for 6 MV photon beams from Varian linacs
    Hermida-Lopez, Marcelino
    Sanchez-Artunedo, David
    Francisco Calvo-Ortega, Juan
    RADIATION ONCOLOGY, 2018, 13