The X-Stop interspinous distraction device has shown to be an attractive alternative to conventional surgical procedures in the treatment of symptomatic degenerative lumbar spinal stenosis. However, the effectiveness of the X-Stop in symptomatic degenerative lumbar spinal stenosis caused by degenerative spondylolisthesis is not known. A cohort of 12 consecutive patients with symptomatic lumbar spinal stenosis caused by degenerative spondylolisthesis were treated with the X-Stop interspinous distraction device. All patients had low back pain, neurogenic claudication and radiculopathy. Pre-operative radiographs revealed an average slip of 19.6%. MRI of the lumbosacral spine showed a severe stenosis. In ten patients, the X-Stop was placed at the L4–5 level, whereas two patients were treated at both, L3–4 and L4–5 level. The mean follow-up was 30.3 months. In eight patients a complete relief of symptoms was observed post-operatively, whereas the remaining 4 patients experienced no relief of symptoms. Recurrence of pain, neurogenic claudication, and worsening of neurological symptoms was observed in three patients within 24 months. Post-operative radiographs and MRI did not show any changes in the percentage of slip or spinal dimensions. Finally, secondary surgical treatment by decompression with posterolateral fusion was performed in seven patients (58%) within 24 months. In conclusion, the X-Stop interspinous distraction device showed an extremely high failure rate, defined as surgical re-intervention, after short term follow-up in patients with spinal stenosis caused by degenerative spondylolisthesis. We do not recommend the X-Stop for the treatment of spinal stenosis complicating degenerative spondylolisthesis.
引用
收藏
页码:188 / 192
页数:4
相关论文
共 50 条
  • [31] A new interspinous process distraction device BacFuse in the treatment of lumbar spinal stenosis with 5 years follow-up study
    Chen, Mengmeng
    Tang, Hai
    Shan, Jianlin
    Chen, Hao
    Jia, Pu
    Bao, Li
    Feng, Fei
    Shi, Guan
    Wang, Ruideng
    MEDICINE, 2020, 99 (26) : E20925
  • [32] Treatment of symptomatic degenerative lumbar spinal stenosis by a percutaneous stand-alone lumbar interspinous implant. Preliminary experience with the Aperius device
    Collignon, F.
    Fransen, P.
    NEUROCHIRURGIE, 2010, 56 (01) : 3 - 7
  • [33] Minimally Invasive Decompression Versus X-Stop in Lumbar Spinal Stenosis A Randomized Controlled Multicenter Study
    Lonne, Greger
    Johnsen, Lars Gunnar
    Rossvoll, Ivar
    Andresen, Hege
    Storheim, Kjersti
    Zwart, John Anker
    Nygaard, Oystein P.
    SPINE, 2015, 40 (02) : 77 - 85
  • [34] Cost-effectiveness of current treatment strategies for lumbar spinal stenosis: nonsurgical care, laminectomy, and X-STOP Clinical article
    Burnett, Mark G.
    Stein, Sherman C.
    Bartels, Ronald H. M. A.
    JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (01) : 39 - 46
  • [35] Quality of life of lumbar stenosis-treated patients in whom the X STOP interspinous device was implanted
    Hsu, Ken Y.
    Zucherman, James F.
    Hartjen, Charles A.
    Mehalic, Thomas F.
    Implicito, Dante A.
    Martin, Michael J.
    Johnson, Donald R., II
    Skidmore, Grant A.
    Vessa, Paul P.
    Dwyer, James W.
    Cauthen, Joseph C.
    Ozuna, Richard M.
    JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (06) : 500 - 507
  • [36] Biomechanical characteristics of a novel interspinous distraction fusion device in the treatment of lumbar degenerative diseases: a finite element analysis
    Chen, Mengmeng
    Deng, Jiechao
    Bao, Li
    Jia, Pu
    Feng, Fei
    Shi, Guan
    Tang, Hai
    Chen, Hao
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [37] Biomechanical characteristics of a novel interspinous distraction fusion device in the treatment of lumbar degenerative diseases: a finite element analysis
    Mengmeng Chen
    Jiechao Deng
    Li Bao
    Pu Jia
    Fei Feng
    Guan Shi
    Hai Tang
    Hao Chen
    BMC Musculoskeletal Disorders, 24
  • [38] Surgical Treatment of the Spinal Stenosis with an Interspinous Distraction Device: Do We Really Restore the Foraminal Height?
    Celik, Haydar
    Derincek, Alihan
    Koksal, Ismet
    TURKISH NEUROSURGERY, 2012, 22 (01) : 50 - 54
  • [39] Lumbar Interspinous Process Fixation and Fusion with Stand-Alone Interlaminar Lumbar Instrumented Fusion Implant in Patients with Degenerative Spondylolisthesis Undergoing Decompression for Spinal Stenosis
    Postacchini, Franco
    Postacchini, Roberto
    Menchetti, Pier Paolo Maria
    Sessa, Pasquale
    Paolino, Michela
    Cinotti, Gianluca
    ASIAN SPINE JOURNAL, 2016, 10 (01) : 27 - 37
  • [40] Percutaneous interspinous distraction device for the treatment of lumbar spinal canal stenosis: Clinical and radiographic results at 2-year follow-up
    Yingsakmongkol, Wicharn
    Chaichankul, Chaiyos
    Limthongkul, Worawat
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2014, 8