Model updating of real structures with ambient vibration data

被引:15
|
作者
Kodikara K.A.T.L. [1 ]
Chan T.H.T. [1 ]
Nguyen T. [1 ]
Thambiratnam D.P. [1 ]
机构
[1] School of Civil Engineering and Built Environment, Queensland University of Technology, Brisbane
关键词
Ambient vibration; Finite element modelling; Model updating; Sensitivity analysis;
D O I
10.1007/s13349-016-0178-3
中图分类号
学科分类号
摘要
It is important to develop reliable finite element models (FEMs) for real structures not only in the design-phase but also for the structural health monitoring and life-cycle management purposes. To do so, model updating is often carried out to minimise the discrepancies between FEMs and real structures. Among existing model updating approaches, sensitivity based model updating methods which can be either manual or automated, have proven to be very effective in the application of real structures and have been widely used on flexible bridge structures. However, very few studies were reported on buildings especially those with medium-rise characteristics which are often associated with complicated initial modelling and different degrees of parameter uncertainties. In addition, even-though a handful of studies has been done on manual model updating for bridge structures, not much research has taken into account the influence of external structural components on manual model updating process. To address these issues, two case studies with real structures are established in this research. One is conducted with a 10-story concrete building to demonstrate the importance of having sufficiently detailed initial FEMs in automated model updating of medium-rise buildings and effective use of boundary limits and parameter groups to maintain the physical relevance of the updated FEMs. Other is an investigation with a single span inflexible foot bridge to highlight the necessity to consider external structural components in manual model updating of inflexible structures. Both studies employ actual ambient vibration monitoring data obtained from the test structures for the model updating processes. © 2016, Springer-Verlag Berlin Heidelberg.
引用
收藏
页码:329 / 341
页数:12
相关论文
共 50 条
  • [31] Finite Element Model Updating of a PSC Box Girder Bridge Using Ambient Vibration Test
    Hiatt, Matthew R.
    Mathiasson, Annika C.
    Okwori, John
    Jin, Seungseop
    Shang, Shen
    Yun, Gunjin
    Caicedo, Juan
    Christenson, Richard
    Yun, Chungbang
    Sohn, Hoon
    ADVANCES IN BUILDING MATERIALS, PTS 1-3, 2011, 168-170 : 2263 - +
  • [32] Finite element model updating for a high-rise structure based on ambient vibration measurements
    Wu, JR
    Li, QS
    ENGINEERING STRUCTURES, 2004, 26 (07) : 979 - 990
  • [33] Ambient vibration testing, system identification and model updating of a multiple-span elevated bridge
    Chen, Xinghua
    Omenzetter, Piotr
    Beskhyroun, Sherif
    EURODYN 2014: IX INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, 2014, : 2377 - 2384
  • [34] Bayesian modal updating using ambient data
    Katafygiotis, LS
    Lam, HF
    Yuen, KV
    IMAC - PROCEEDINGS OF THE 16TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS 1 AND 2, 1998, 3243 : 667 - 673
  • [35] Bayesian modal updating by use of ambient data
    Katafygiotis, LS
    Yuen, KV
    Chen, JC
    AIAA JOURNAL, 2001, 39 (02) : 271 - 278
  • [36] Ambient vibration tests of hydraulic structures
    Abdel-Rahman, SM
    Helal, MA
    PROCEEDINGS OF IMAC-XX: STRUCTURAL DYNAMICS VOLS I AND II, 2002, 4753 : 816 - 823
  • [37] Ambient vibration-based finite element model updating of an earthquake-damaged masonry tower
    Bassoli, Elisa
    Vincenzi, Loris
    D'Altri, Antonio Maria
    de Miranda, Stefano
    Forghieri, Marianna
    Castellazzi, Giovanni
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (05):
  • [38] Model updating of a historical building by using ambient vibration tests. Chapel of the Wurzburg Residence (Germany)
    Compan, Victor
    Pachon, Pablo
    Camara, Margarita
    Saez, Andres
    3RD INTERNATIONAL CONFERENCE ON MECHANICAL MODELS IN STRUCTURAL ENGINEERING (CMMOST 2015), 2015, : 361 - 372
  • [39] Automatic Updating Method of Finite Element Model and Its Application Based on Ambient Vibration and Bayesian Theorem
    Liu P.
    Zhu H.
    Lian P.
    Yang W.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2019, 47 (07): : 49 - 57
  • [40] Model Updating with Operating Vibration Analysis
    Guggenberger, Johannes
    Dascotte, Eddy
    SCHWINGUNGSANALYSE AND IDENTIFIKATION: MIT FACHAUSSTELLUNG, 2010, 2093 : 37 - 47