Water flow meter calibration with a master meter method

被引:0
|
作者
Sejong Chun
Byung-Ro Yoon
Hae-Man Choi
Yong Bong Lee
机构
[1] Korea Research Institute of Standards and Science,Division of Physical Metrology
关键词
Calibration; Flow meter; Master meter; Measurement uncertainty; Water flow;
D O I
暂无
中图分类号
学科分类号
摘要
Master meter method is an efficient way to calibrate flow meters with less time and costs. The master meter method has simpler flow configuration than the gravimetric flow measurement method requires. Maintenance efforts of the master meter method are easier than the gravimetric method. However, the guidelines of master meter method have not been established completely. It is because the notion of relative deviations, which are used as a measure and for comparison calibration, is not clearly understood. On the other hand, the system uncertainty, which is typically used as the calibration and measurement capability of the gravimetric flow standards, are understood very well. In this study, a complete explanation on the master meter method is attempted. First, appropriate calibration conditions are assumed. Second, a suitable calibration procedure is suggested. Third, a mathematical model for the relative deviations is described. Fourth, uncertainty factors of the relative deviations are evaluated. Finally, two examples of the comparison calibration are explained in detail. The master meter method is compatible with the guide to the expression of uncertainty in measurement (GUM, ISO/IEC Guide 98-3:2008). In the examples, it is found that the master meter method can achieve the measurement uncertainty as low as 0.20%.
引用
收藏
页码:1075 / 1083
页数:8
相关论文
共 50 条
  • [41] Numerical calibration and unsteady cavitation simulation of turbine flow meter
    Chen, Gang
    Cao, Guang-Jun
    Fu, Su-Hong
    Li, Ji-Feng
    Zhang, Dong-Sheng
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (SUPPL.): : 269 - 272
  • [42] Bayesian estimation of a polynomial calibration function associated to a flow meter
    Yardin, C.
    Amar, S.
    Fischer, N.
    Sancandi, M.
    Keller, M.
    ADVANCED MATHEMATICAL AND COMPUTATIONAL TOOLS IN METROLOGY AND TESTING XI, 2019, 89 : 417 - 426
  • [43] CALIBRATION OF A FLOSCOPE PEAK FLOW METER AND A VITALOGRAPH PULMONARY MONITOR
    FISHER, J
    SHAW, A
    ANAESTHESIA, 1981, 36 (09) : 886 - 888
  • [44] ANALYTICAL PROCEDURE OF CALIBRATION FOR PULSED ULTRASONIC DOPPLER FLOW METER
    JORGENSEN, JE
    GARBINI, JL
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1974, 96 (02): : 158 - 167
  • [45] Simulation of flow meter calibration factors for various installation effects
    Lund Inst of Technology, Lund, Sweden
    Meas J Int Meas Confed, 4 (235-244):
  • [46] Line in flow-meter calibration advance methods and solutions
    Sagi, H
    Roberts, WG
    SUCCESS IN THE 21ST CENTURY DEPENDS ON MODERN METROLOGY, VOLS 1-2, 1997, : 383 - 399
  • [47] Blow-down calibration of a large ultrasonic flow meter
    Johnson, Aaron N.
    Harman, Eric
    Boyd, Joey T.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 77 (77)
  • [48] DYNAMIC TURBINE METER CALIBRATION
    不详
    INSTRUMENTATION TECHNOLOGY, 1970, 17 (03): : 57 - &
  • [49] Current meter calibration strategy
    Engel, P
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1999, 125 (12): : 1306 - 1308
  • [50] PHASE METER CALIBRATION AT NBS