Impedimetric Salmonella aptasensor using a glassy carbon electrode modified with an electrodeposited composite consisting of reduced graphene oxide and carbon nanotubes

被引:0
|
作者
Fei Jia
Nuo Duan
Shijia Wu
Ruitong Dai
Zhouping Wang
Xingmin Li
机构
[1] China Agricultural University,College of Food Science and Nutritional Engineering
[2] Jiangnan University,State Key Laboratory of Food Science and Technology, School of Food Science and Technology
[3] Beijing Higher Institution Engineering Research Center of Animal Product,undefined
来源
Microchimica Acta | 2016年 / 183卷
关键词
Multi-walled carbon nanotubes; Electrodeposition; Transmission electron microscopy; Scanning electron microscopy; Cyclic voltammetry; Electrochemical impedance spectroscopy; anti-; aptamer;
D O I
暂无
中图分类号
学科分类号
摘要
We describe a Salmonella biosensor that was obtained by electrochemical immobilization of a nanocomposite consisting of reduced graphene oxide (rGO) and carboxy-modified multi-walled carbon nanotubes (MWCNTs) directly on the surface of a glassy carbon electrode (GCE). An amino-modified aptamer specific for Salmonella was covalently bound to the rGO-MWCNT composite via amide bonds. The morphology of the rGO-MWCNT nanocomposite was characterized by transmission electron microscopy and scanning electron microscopy. Cyclic voltammetry and electrochemical impedance spectroscopy were used to monitor all steps during assembly. When exposed to samples containing Salmonella, the anti-Salmonella aptamer on the electrode captures its target. Hence, electron transfer is blocked, and this results in a large increase in impedance. Salmonella can be quantified by this aptasensor, typically operated at a working voltage of 0.2 V (vs. Ag/AgCl), in the range from 75 to 7.5 × 105 cfu⋅mL−1 and detection limit of 25 cfu⋅mL−1 (at an S/N of 3). The method is perceived to have a wide scope in that other bacteria may be detected by analogy to this approach and with very low limits of detection by applying respective analyte-specific aptamers.
引用
收藏
页码:337 / 344
页数:7
相关论文
共 50 条
  • [31] Impedimetric PSA aptasensor based on the use of a glassy carbon electrode modified with titanium oxide nanoparticles and silk fibroin nanofibers
    Benvidi, Ali
    Banaei, Maryam
    Tezerjani, Marzieh Dehghan
    Molahosseini, Hosein
    Jahanbani, Shahriar
    MICROCHIMICA ACTA, 2018, 185 (01)
  • [32] Impedimetric PSA aptasensor based on the use of a glassy carbon electrode modified with titanium oxide nanoparticles and silk fibroin nanofibers
    Ali Benvidi
    Maryam Banaei
    Marzieh Dehghan Tezerjani
    Hosein Molahosseini
    Shahriar Jahanbani
    Microchimica Acta, 2018, 185
  • [33] Voltammetric determination of the endocrine disruptor diethylstilbestrol by using a glassy carbon electrode modified with a composite consisting of platinum nanoparticles and multiwalled carbon nanotubes
    Xiaobin Hu
    Rongfei Zhang
    Microchimica Acta, 2016, 183 : 3069 - 3076
  • [34] Voltammetric determination of the endocrine disruptor diethylstilbestrol by using a glassy carbon electrode modified with a composite consisting of platinum nanoparticles and multiwalled carbon nanotubes
    Hu, Xiaobin
    Zhang, Rongfei
    MICROCHIMICA ACTA, 2016, 183 (11) : 3069 - 3076
  • [35] A glassy carbon electrode modified with carbon nanotubes and reduced graphene oxide decorated with platinum-gold nanoparticles for voltammetric aptasensing of urea
    Hamed Momenzadeh
    Azadeh Azadbakht
    Microchimica Acta, 2017, 184 : 4685 - 4694
  • [36] A glassy carbon electrode modified with carbon nanotubes and reduced graphene oxide decorated with platinum-gold nanoparticles for voltammetric aptasensing of urea
    Momenzadeh, Hamed
    Azadbakht, Azadeh
    MICROCHIMICA ACTA, 2017, 184 (12) : 4685 - 4694
  • [37] Voltammetric Sensing of Bilirubin Based on Nafion/Electrochemically Reduced Graphene Oxide Composite Modified Glassy Carbon Electrode
    Avan, Asiye Aslihan
    Aydar, Sevda
    Filik, Hayati
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 96 - 103
  • [38] In Situ Determination of Bisphenol A in Beverage Using a Molybdenum Selenide/Reduced Graphene Oxide Nanoparticle Composite Modified Glassy Carbon Electrode
    Shi, Rongguang
    Liang, Jing
    Zhao, Zongshan
    Liu, Yi
    Liu, Aifeng
    SENSORS, 2018, 18 (05)
  • [39] Electrochemical sensing of phenacetin on electrochemically reduced graphene oxide modified glassy carbon electrode
    Meng, Xiao-Tong
    Zhu, De-Jing
    Jiang, Yu-Hang
    Cao, Yue
    Si, Wei-Meng
    Cao, Jun
    Li, Qiu-Hong
    Li, Jiao
    Lei, Wu
    NEW CARBON MATERIALS, 2022, 37 (04) : 764 - 771
  • [40] Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide
    Lisnund, Sireerat
    Blay, Vincent
    Chansaenpak, Kantapat
    Pinyou, Piyanut
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7214 - 7227