Conductivity Measurement of Non-magnetic Material Using the Phase Feature of Eddy Current Testing

被引:0
|
作者
Pu Huang
Zhiying Li
Hang Pu
Jieshu Jia
Kuanyao Liu
Lijun Xu
Yuedong Xie
机构
[1] Beihang University,School of Instrumentation and Opto
[2] Shanghai Radio Equipment Research Institute,Electronic Engineering
来源
关键词
Eddy current testing; Conductivity measurement; Lift-off suppression; Phase of coil; Effect of coil size;
D O I
暂无
中图分类号
学科分类号
摘要
Eddy current testing (ECT) have been widely applied for electromagnetic parameters measurement and structural health monitoring due to the advantages of non-contact and high sensitivity. However, lift-off variation affects the measurement accuracy of ECT. In this paper, a novel strategy to handle this issue has been proposed for conductivity measurement of non-magnetic materials. First of all, a simplified analytical solution is derived from classical Dodd-Deeds analytical solution. According to the simplified analytical solution, the conductivity of sample is proved to be proportional to reciprocal of the crossover frequency with phase equaling to -3π/4\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${{ - 3\pi } \mathord{\left/ {\vphantom {{ - 3\pi } 4}} \right. \kern-0pt} 4}$$\end{document}. Hence, the conductivity of samples can be estimated based on the characteristics. Furthermore, compared with magnitude signal of ECT, the phase feature is demonstrated minimally affected by lift-off variation from aspects of theoretical derivation. Meanwhile, we have also analyzed the relationship between size of coil and lift-off suppression capability of phase measurement through simplified analytical solution. Specifically, as coil size increases, the influence of lift-off fluctuations can be ignored on phase measurement in ECT. In order to verify the prosed strategy, the experiments involving samples with different conductivities and coils with different sizes have been carried out. The results indicate the proposed method can achieve high precise conductivity measurement and suppress the interference caused by lift-off to some extent.
引用
收藏
相关论文
共 50 条
  • [31] Non-contact Thin Layer Conductivity Measurement Based on the Conjugate Magnetic Eddy Current Sensor
    Yan, Youjun
    Zhao, Dan
    Zhen, Yu
    INTERNATIONAL CONFERENCE ON ELECTRONIC INFORMATION TECHNOLOGY AND INTELLECTUALIZATION (ICEITI 2016), 2016, : 55 - 62
  • [32] Remote field eddy current technique applied to non-magnetic steam generator tubes
    Fukutomi, H
    Takagi, T
    Nishikawa, M
    NDT & E INTERNATIONAL, 2001, 34 (01) : 17 - 23
  • [33] Electromagnetic testing of magnetic material by rotating uniform eddy current probe
    Hoshikawa, H
    Koyama, K
    Mitsuhashi, S
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 25A AND 25B, 2006, 820 : 423 - 430
  • [34] Through Thickness Inspection of Layered Magnetic Material Using Pulsed Eddy-Current Testing
    Xiong, Lei
    Xia, Zihan
    Huang, Ruochen
    Wang, Shupei
    Zheng, Xinnan
    Shen, Jialong
    Pang, Xiaochu
    Yin, Wuliang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [35] Measurement of radius of a metallic ball using eddy current testing based on peak frequency difference feature
    Hu, Gang
    Huang, Ruochen
    Lu, Mingyang
    Zhou, Lei
    Yin, Wuliang
    MEASUREMENT, 2021, 184 (184)
  • [36] EDDY CURRENT SIMULATIONS AND MEASUREMENTS OF SODIUM EFFECT FOR MAGNETIC AND NON-MAGNETIC STEAM GENERATOR TUBES OF FBR
    Mihalache, Ovidiu
    Yamaguchi, Toshihiko
    Ueda, Masashi
    Miyahara, Shinya
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 28A AND 28B, 2009, 1096 : 580 - 587
  • [37] Eddy current testing using a model based measurement method
    Luo, FL
    Hu, YY
    Kang, ZW
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 : 667 - 672
  • [38] Thickness and Conductivity Measurement of Nonferromagnetic Metal Coating Using Apparent Eddy Current Conductivity
    Wang, Dongli
    Xu, Jin
    Xin, Wei
    Zhu, Silong
    Han, Yunan
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 1
  • [39] Eddy Current Testing in Thickness Measurement of Material with Multi-layer Structure
    Chen, Peihua
    Huang, Pingjie
    Li, Guohou
    Cai, Wen
    Zhou, Zekui
    CCDC 2009: 21ST CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-6, PROCEEDINGS, 2009, : 2065 - 2068
  • [40] Measurement of the thickness of non-magnetic strata
    Redepenning, W
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1939, 83 : 1071 - 1071