Sensitivity improvement using optimized heater design for dual axis thermal accelerometers

被引:0
|
作者
R. Mukherjee
P. K. Guha
P. Mandal
机构
[1] Indian Institute of Technology,Department of Electronics and Electrical Communication Engineering
来源
Microsystem Technologies | 2016年 / 22卷
关键词
Heater Temperature; Temperature Detector; Polysilicon; Supporting Beam; Instrumentation Amplifier;
D O I
暂无
中图分类号
学科分类号
摘要
This paper investigates the sensitivity improvement of an air filled cavity based thermal accelerometer. The accelerometer does not contain any solid proof mass and it is realizable in CMOS technology. The sensitivity has been improved by a new square ring shaped heater structure. The sensitivity of accelerometer performance is compared with other different heater shapes. It is found that, heater design having higher heat dissipation in the suspended beam gives higher sensitivity. The simulation is carried out using commercial FEM simulator COMSOL Multiphysics. For the peak heater temperature of 609 K, the proposed square ring shaped heater provides a sensitivity of 0.335 K/g. Under same conditions, sensitivity of an accelerometer with a meander shaped heater structure is only 0.098 K/g and diamond shaped structure is 0.229 K/g.
引用
收藏
页码:2475 / 2485
页数:10
相关论文
共 50 条
  • [21] Improvement of vertical axis wind turbine performance by using the optimized adaptive flap by the Taguchi method
    Tanurun, Himmet Erdi
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 71 - 90
  • [22] Design of movable bracket for dual-axis tracking solar thermal power system
    Song, Bo
    Zhang, Yong
    Xu, Fang Bin
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1830 - 1835
  • [23] Enhanced 3-axis sensitivity of a CMOS MEMS convective accelerometer using a new power efficient heater structure
    Abdellatif, Sonia
    Mezghani, Brahim
    Mailly, Frederick
    Nouet, Pascal
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2022, 28 (04): : 1011 - 1023
  • [24] Enhanced 3-axis sensitivity of a CMOS MEMS convective accelerometer using a new power efficient heater structure
    Sonia Abdellatif
    Brahim Mezghani
    Frederick Mailly
    Pascal Nouet
    Microsystem Technologies, 2022, 28 : 1011 - 1023
  • [25] An error analysis and efficient calibration method for 6 DOF acceleration sensor systems using multiple dual-axis accelerometers
    Faculty of Engineering, Niigata University, 8050 Ikarashi-2, Niigata-shi, Niigata, 950-2181, Japan
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2008, 74 (03): : 626 - 632
  • [26] Optimized electric heater configuration design with magnetic-field self-suppression using genetic algorithm
    Lu, Jixi
    Lu, Chenning
    Wang, Shuying
    Zhang, Xu
    Zhang, Shaowen
    Lu, Fei
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 344
  • [27] Design and performance improvement of a solar desalination system by using solar air heater: Experimental and theoretical approach
    Siddiqui, Farooq R.
    Elminshawy, Nabil A. S.
    Addas, Mohammad F.
    DESALINATION, 2016, 399 : 78 - 87
  • [28] Quality Improvement of Millimeter-Wave Imaging Systems Using Optimized Dual Polarized Arrays
    Rezaei, Milad
    Zamani, Hojatollah
    Fakharzadeh, Mohammad
    Memarian, Mohammad
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2021, 69 (10) : 6848 - 6856
  • [29] Motorcycle Dual Exhaust Muffler Design Improvement to Eliminate Failure Caused by Thermal Stress
    Bansode, Narendra V.
    Ganguly, Arnab
    Agarwal, Vikas Kumar
    SAE INTERNATIONAL JOURNAL OF ENGINES, 2016, 9 (03) : 1833 - 1838
  • [30] Sensorless and Power-Optimized Sun Tracking for CPV Applications Using Dual-Axis Trackers
    Stalter, Olivier
    Burger, Bruno
    6TH INTERNATIONAL CONFERENCE ON CONCENTRATING PHOTOVOLTAIC SYSTEMS (CPV-6), 2010, 1277 : 137 - 140