Delineation of Groundwater Potential and Recharge Zone Using Electrical Resistivity Method Around Veeranam Tank, Tamil Nadu, India

被引:3
|
作者
Sathiyamoorthy M. [1 ]
Ganesan M. [1 ]
机构
[1] Centre for Water Resources, Anna University, Chennai
关键词
Electrical resistivity; Geo-electrical parameters; Groundwater potential zones; Subsurface formation; Thickness;
D O I
10.1007/s40030-018-0318-3
中图分类号
学科分类号
摘要
Veeranam tank is one of the largest tank in Tamil Nadu, India which plays a vital role in groundwater recharge to the surrounding aquifer. Electrical resistivity survey were carried out in ten locations around the Veeranam tank. The resistivity, thickness of subsurface formations, longitudinal conductance (S), transverse resistance (R), average longitudinal resistivity (ST), average transverse resistivity (RT) and anisotropy (λ) were used to characterize the lithological formations and also groundwater potential and recharge zones were delineated. The four major zones clay, clayey sand, saline sand and sandstone were identified as a result of primary geo-electrical parameters which includes resistivity and thickness of the formations. The sandstone formation is identified as good water bearing formation and this formation possess low longitudinal conductance, high transverse resistance, and low anisotropy values. The clay and saline formation possess high longitudinal conductance, low transverse resistance and high anisotropy values and these formations are identified as moderate groundwater water bearing formations. High longitudinal conductance is observed in eastern region of the study area due to intrusion of saline water. Sandstone formation of low longitudinal conductance is associated with high percolation rate and groundwater potential is also good in this formation. High transverse resistance zones are associated with high infiltration rate and high transmissivity whereas groundwater potential is good in these zones. VES 2 and VES 3 stations comprises of sandstone formation as second layer and Veeranam tank water infiltrated into these zones due to high infiltration rate of these formations. The resistivity value is decreased in VES 10 station due to intrusion of sea water. The true resistivity near the Veeranam tank is high and decreases towards east which clearly indicates that groundwater recharge is the major process that occurs nearby the downstream shore of tank and intrusion of saline water in the eastern part of the study area. Thus good interaction between exists between Veeranam tank and its downstream zones and interaction decreases as the distance increases from the tank. © 2018, The Institution of Engineers (India).
引用
收藏
页码:637 / 645
页数:8
相关论文
共 50 条
  • [21] Assessment of groundwater potential zones in Vellore district, Tamil Nadu, India using geospatial techniques
    Kanagaraj, G.
    Suganthi, S.
    Elango, L.
    Magesh, N. S.
    EARTH SCIENCE INFORMATICS, 2019, 12 (02) : 211 - 223
  • [22] Delineation of groundwater potential zones in Theni district, Tamil Nadu, using remote sensing, GIS and MIF techniques
    Magesh, N. S.
    Chandrasekar, N.
    Soundranayagam, John Prince
    GEOSCIENCE FRONTIERS, 2012, 3 (02) : 189 - 196
  • [23] Delineation of groundwater potential zones in Theni district,Tamil Nadu,using remote sensing,GIS and MIF techniques
    N.S.Magesh
    N.Chandrasekar
    John Prince Soundranayagam
    Geoscience Frontiers, 2012, 3 (02) : 189 - 196
  • [24] Delineation of groundwater potential zones in Theni district,Tamil Nadu,using remote sensing,GIS and MIF techniques
    N.S.Magesh
    N.Chandrasekar
    John Prince Soundranayagam
    Geoscience Frontiers, 2012, (02) : 189 - 196
  • [25] Groundwater recharge potential zones mapping in upper Manimuktha Sub basin Vellar river Tamil Nadu India using GIS and remote sensing techniques
    Deepa S.
    Venkateswaran S.
    Ayyandurai R.
    Kannan R.
    Vijay Prabhu M.
    Modeling Earth Systems and Environment, 2016, 2 (3)
  • [26] Application of remote sensing and GIS for delineating groundwater recharge potential zones of Kovilpatti Municipality, Tamil Nadu using IF technique
    S. Selvam
    Farooq A. Dar
    N. S. Magesh
    C. Singaraja
    S. Venkatramanan
    S. Y. Chung
    Earth Science Informatics, 2016, 9 : 137 - 150
  • [27] Application of remote sensing and GIS for delineating groundwater recharge potential zones of Kovilpatti Municipality, Tamil Nadu using IF technique
    Selvam, S.
    Dar, Farooq A.
    Magesh, N. S.
    Singaraja, C.
    Venkatramanan, S.
    Chung, S. Y.
    EARTH SCIENCE INFORMATICS, 2016, 9 (02) : 137 - 150
  • [28] Identifying groundwater recharge zones using remote sensing & GIS techniques in Amaravathi aquifer system, Tamil Nadu, South India
    Mohanavelu Senthilkumar
    Devadasan Gnanasundar
    Rethinam Arumugam
    Sustainable Environment Research, 29
  • [29] Identifying groundwater recharge zones using remote sensing & GIS techniques in Amaravathi aquifer system, Tamil Nadu, South India
    Senthilkumar, Mohanavelu
    Gnanasundar, Devadasan
    Arumugam, Rethinam
    SUSTAINABLE ENVIRONMENT RESEARCH, 2019, 29 (1)
  • [30] Evaluation of groundwater potential zones using GIS and remote sensing in Noyyal Basin, Tamil Nadu, India
    Selvarani, A. Geetha
    Maheswaran, G.
    Elangovan, K.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL TECHNOLOGY AND MANAGEMENT, 2014, 17 (05) : 377 - 392