Failure analysis of a high-temperature thermocouple

被引:6
|
作者
Gates K. [1 ]
Benhaddad S. [2 ]
机构
[1] Thermex Metal Treating, Edmonton, Alta. T6P 1N8
[2] Versa Power Systems, Calgary, Alta. T2B 3R2
关键词
Catastrophic failure; Contamination; Failure analysis; High temperature; Materials selection; Metallurgical investigation; Nonferrous metals;
D O I
10.1361/154770205X55108
中图分类号
学科分类号
摘要
A solid oxide fuel cell unit operates at high temperatures of 700 to 800 °C. The operation of the unit is controlled by a set of instrumentation including sensors, thermocouples, and voltage leads. Two S-thermocouples were inserted in the after-burner where temperature is constantly at 1000 °C. During operation of one prototype unit and after 1000 h, the thermocouples started to give erratic readings and led to complete shutdown of the unit. Analysis of the thermocouples revealed a series of events may have occurred due to stress induced by the design, materials and operating conditions, contamination during manufacturing, or a reducing environment caused by sheathing. The specification from S-type to B-type may remove the risk of reoccurrence. A design change in platinum burner thermocouples to ensure an oxygen-rich environment for the platinum was also recommended. © ASM International.
引用
收藏
页码:14 / 19
页数:5
相关论文