Image quality of CT angiography with model-based iterative reconstruction in young children with congenital heart disease: comparison with filtered back projection and adaptive statistical iterative reconstruction

被引:0
|
作者
Sung Sil Son
Ki Seok Choo
Ung Bae Jeon
Gye Rok Jeon
Kyung Jin Nam
Tae Un Kim
Jeong A Yeom
Jae Yeon Hwang
Dong Wook Jeong
Soo Jin Lim
机构
[1] Pusan National University School of Medicine,Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital
[2] Pusan National University,Department of Biomedical
[3] Pusan National University School of Medicine,Engineering, The Graduate School
[4] Kim Hae Jungang Hospital,Department of Family Medicine, Pusan National University Yangsan Hospital
关键词
Computed tomography; Heart; Congenital defect;
D O I
暂无
中图分类号
学科分类号
摘要
To retrospectively evaluate the image quality of CT angiography (CTA) reconstructed by model-based iterative reconstruction (MBIR) and to compare this with images obtained by filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) in newborns and infants with congenital heart disease (CHD). Thirty-seven children (age 4.8 ± 3.7 months; weight 4.79 ± 0.47 kg) with suspected CHD underwent CTA on a 64detector MDCT without ECG gating (80 kVp, 40 mA using tube current modulation). Total dose length product was recorded in all patients. Images were reconstructed using FBP, ASIR, and MBIR. Objective image qualities (density, noise) were measured in the great vessels and heart chambers. The contrast-to-noise ratio (CNR) was calculated by measuring the density and noise of myocardial walls. Two radiologists evaluated images for subjective noise, diagnostic confidence, and sharpness at the level prior to the first branch of the main pulmonary artery. Images were compared with respect to reconstruction method, and reconstruction times were measured. Images from all patients were diagnostic, and the effective dose was 0.22 mSv. The objective image noise of MBIR was significantly lower than those of FBP and ASIR in the great vessels and heart chambers (P < 0.05); however, with respect to attenuations in the four chambers, ascending aorta, descending aorta, and pulmonary trunk, no statistically significant difference was observed among the three methods (P > 0.05). Mean CNR values were 8.73 for FBP, 14.54 for ASIR, and 22.95 for MBIR. In addition, the subjective image noise of MBIR was significantly lower than those of the others (P < 0.01). Furthermore, while FBP had the highest score for image sharpness, ASIR had the highest score for diagnostic confidence (P < 0.05), and mean reconstruction times were 5.1 ± 2.3 s for FBP and ASIR and 15.1 ± 2.4 min for MBIR. While CTA with MBIR in newborns and infants with CHD can reduce image noise and improve CNR more than other methods, it is more time-consuming than the other methods.
引用
收藏
页码:31 / 38
页数:7
相关论文
共 50 条
  • [31] Knowledge-based iterative model reconstruction in coronary computed tomography angiography: comparison with hybrid iterative reconstruction and filtered back projection
    Cha, Min Jae
    Seo, Jae Seung
    Yoo, Dong Soo
    Chong, Semin
    ACTA RADIOLOGICA, 2018, 59 (03) : 280 - 286
  • [32] Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Akahane, Masaaki
    Sato, Jiro
    Matsuda, Izuru
    Ohtomo, Kuni
    SPRINGERPLUS, 2013, 2 : 1 - 9
  • [33] Image quality of CT angiography in young children with congenital heart disease: a comparison between the sinogram-affirmed iterative reconstruction (SAFIRE) and advanced modelled iterative reconstruction (ADMIRE) algorithms
    Nam, S. B.
    Jeong, D. W.
    Choo, K. S.
    Nam, K. J.
    Hwang, J. -Y.
    Lee, J. W.
    Kim, J. Y.
    Lim, S. J.
    CLINICAL RADIOLOGY, 2017, 72 (12) : 1060 - 1065
  • [34] Pediatric Head CT Image Quality With Iterative Reconstruction Versus Filtered Back Projection
    Oberle, R.
    Kim, E.
    Wu, I.
    Ho, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [35] Evaluation of Heavily Calcified Vessels with Coronary CT Angiography: Comparison of Iterative and Filtered Back Projection Image Reconstruction
    Renker, Matthias
    Nance, John W., Jr.
    Schoepf, U. Joseph
    O'Brien, Terrence X.
    Zwerner, Peter L.
    Meyer, Mathias
    Kerl, J. Matthias
    Bauer, Ralf W.
    Fink, Christian
    Vogl, Thomas J.
    Henzler, Thomas
    RADIOLOGY, 2011, 260 (02) : 390 - 399
  • [36] Model-Based Iterative Reconstruction Versus Adaptive Statistical Iterative Reconstruction and Filtered Back Projection in Liver 64-MDCT: Focal Lesion Detection, Lesion Conspicuity, and Image Noise
    Shuman, William P.
    Green, Doug E.
    Busey, Janet M.
    Kolokythas, Orpheus
    Mitsumori, Lee M.
    Koprowicz, Kent M.
    Thibault, Jean-Baptiste
    Hsieh, Jiang
    Alessio, Adam M.
    Choi, Eunice
    Kinahan, Paul E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : 1071 - 1076
  • [37] Assessment of Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction for Reduced Dose Abdominal Computed Tomography
    Padole, Atul
    Singh, Sarabjeet
    Lira, Diego
    Blake, Michael A.
    Pourjabbar, Sarvenaz
    Khawaja, Ranish Deedar Ali
    Choy, Garry
    Saini, Sanjay
    Do, Synho
    Kalra, Mannudeep K.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 462 - 467
  • [38] CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Keita Kuya
    Yuki Shinohara
    Makoto Sakamoto
    Naoki Iwata
    Junichi Kishimoto
    Shinya Fujii
    Toshio Kaminou
    Takashi Watanabe
    Toshihide Ogawa
    Neuroradiology, 2014, 56 : 947 - 953
  • [39] CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Kuya, Keita
    Shinohara, Yuki
    Sakamoto, Makoto
    Iwata, Naoki
    Kishimoto, Junichi
    Fujii, Shinya
    Kaminou, Toshio
    Watanabe, Takashi
    Ogawa, Toshihide
    NEURORADIOLOGY, 2014, 56 (11) : 947 - 953
  • [40] Image Quality Assessment in Torso Phantom Comparing Effects of Varying Automatic Current Modulation with Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction Techniques in CT
    Vardhanabhuti, Varut
    Olubaniyi, Babajide
    Loader, Robert
    Riordan, Richard D.
    Williams, Michael P.
    Roobottom, Carl A.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2012, 43 (04) : 228 - 238