Image quality of CT angiography with model-based iterative reconstruction in young children with congenital heart disease: comparison with filtered back projection and adaptive statistical iterative reconstruction

被引:0
|
作者
Sung Sil Son
Ki Seok Choo
Ung Bae Jeon
Gye Rok Jeon
Kyung Jin Nam
Tae Un Kim
Jeong A Yeom
Jae Yeon Hwang
Dong Wook Jeong
Soo Jin Lim
机构
[1] Pusan National University School of Medicine,Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital
[2] Pusan National University,Department of Biomedical
[3] Pusan National University School of Medicine,Engineering, The Graduate School
[4] Kim Hae Jungang Hospital,Department of Family Medicine, Pusan National University Yangsan Hospital
关键词
Computed tomography; Heart; Congenital defect;
D O I
暂无
中图分类号
学科分类号
摘要
To retrospectively evaluate the image quality of CT angiography (CTA) reconstructed by model-based iterative reconstruction (MBIR) and to compare this with images obtained by filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) in newborns and infants with congenital heart disease (CHD). Thirty-seven children (age 4.8 ± 3.7 months; weight 4.79 ± 0.47 kg) with suspected CHD underwent CTA on a 64detector MDCT without ECG gating (80 kVp, 40 mA using tube current modulation). Total dose length product was recorded in all patients. Images were reconstructed using FBP, ASIR, and MBIR. Objective image qualities (density, noise) were measured in the great vessels and heart chambers. The contrast-to-noise ratio (CNR) was calculated by measuring the density and noise of myocardial walls. Two radiologists evaluated images for subjective noise, diagnostic confidence, and sharpness at the level prior to the first branch of the main pulmonary artery. Images were compared with respect to reconstruction method, and reconstruction times were measured. Images from all patients were diagnostic, and the effective dose was 0.22 mSv. The objective image noise of MBIR was significantly lower than those of FBP and ASIR in the great vessels and heart chambers (P < 0.05); however, with respect to attenuations in the four chambers, ascending aorta, descending aorta, and pulmonary trunk, no statistically significant difference was observed among the three methods (P > 0.05). Mean CNR values were 8.73 for FBP, 14.54 for ASIR, and 22.95 for MBIR. In addition, the subjective image noise of MBIR was significantly lower than those of the others (P < 0.01). Furthermore, while FBP had the highest score for image sharpness, ASIR had the highest score for diagnostic confidence (P < 0.05), and mean reconstruction times were 5.1 ± 2.3 s for FBP and ASIR and 15.1 ± 2.4 min for MBIR. While CTA with MBIR in newborns and infants with CHD can reduce image noise and improve CNR more than other methods, it is more time-consuming than the other methods.
引用
收藏
页码:31 / 38
页数:7
相关论文
共 50 条
  • [1] Image quality of CT angiography with model-based iterative reconstruction in young children with congenital heart disease: comparison with filtered back projection and adaptive statistical iterative reconstruction
    Son, Sung Sil
    Choo, Ki Seok
    Jeon, Ung Bae
    Jeon, Gye Rok
    Nam, Kyung Jin
    Kim, Tae Un
    Yeom, Jeong A.
    Hwang, Jae Yeon
    Jeong, Dong Wook
    Lim, Soo Jin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 31 - 38
  • [2] Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction
    Jia, Qianjun
    Zhuang, Jian
    Jiang, Jun
    Li, Jiahua
    Huang, Meiping
    Liang, Changhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 190 - 197
  • [3] Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp
    Kim, Jin Hyeok
    Choo, Ki Seok
    Moon, Tae Yong
    Lee, Jun Woo
    Jeon, Ung Bae
    Kim, Tae Un
    Hwang, Jae Yeon
    Yun, Myeong-Ja
    Jeong, Dong Wook
    Lim, Soo Jin
    EUROPEAN RADIOLOGY, 2016, 26 (07) : 2055 - 2063
  • [4] Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp
    Jin Hyeok Kim
    Ki Seok Choo
    Tae Yong Moon
    Jun Woo Lee
    Ung Bae Jeon
    Tae Un Kim
    Jae Yeon Hwang
    Myeong-Ja Yun
    Dong Wook Jeong
    Soo Jin Lim
    European Radiology, 2016, 26 : 2055 - 2063
  • [5] Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study
    Deak, Zsuzsanna
    Grimm, Jochen M.
    Treitl, Marcus
    Geyer, Lucas L.
    Linsenmaier, Ulrich
    Koerner, Markus
    Reiser, Maximilian F.
    Wirth, Stefan
    RADIOLOGY, 2013, 266 (01) : 197 - 206
  • [6] Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions
    Goodenberger, Martin H.
    Wagner-Bartak, Nicolaus A.
    Gupta, Shiva
    Liu, Xinming
    Yap, Ramon Q.
    Sun, Jia
    Tamm, Eric P.
    Jensen, Corey T.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 184 - 190
  • [7] CT of the pancreas: comparison of image quality and pancreatic duct depiction among model-based iterative, adaptive statistical iterative, and filtered back projection reconstruction techniques
    Xiao-Zhu Lin
    Haruhiko Machida
    Isao Tanaka RT
    Rika Fukui RT
    Eiko Ueno
    Ke-Min Chen
    Fu-Hua Yan
    Abdominal Imaging, 2014, 39 : 497 - 505
  • [8] CT of the pancreas: comparison of image quality and pancreatic duct depiction among model-based iterative, adaptive statistical iterative, and filtered back projection reconstruction techniques
    Lin, Xiao-Zhu
    Machida, Haruhiko
    Tanaka, Isao
    Fukui, Rika
    Ueno, Eiko
    Chen, Ke-Min
    Yan, Fu-Hua
    ABDOMINAL IMAGING, 2014, 39 (03): : 497 - 505
  • [9] Comparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography
    Kuo, Yu
    Lin, Yi-Yang
    Lee, Rheun-Chuan
    Lin, Chung-Jung
    Chiou, Yi-You
    Guo, Wan-Yuo
    MEDICINE, 2016, 95 (31)
  • [10] Model-based Iterative Reconstruction Compared to Adaptive Statistical Iterative Reconstruction and Filtered Back-projection in CT of the Kidneys and the Adjacent Retroperitoneum
    Olcott, Eric W.
    Shin, Lewis K.
    Sommer, Graham
    Chan, Ian
    Rosenberg, Jarrett
    Molvin, F. Lior
    Boas, F. Edward
    Fleischmann, Dominik
    ACADEMIC RADIOLOGY, 2014, 21 (06) : 774 - 784