Weaning from mechanical ventilation: a model for extubation

被引:0
|
作者
A. A. Zeggwagh
R. Abouqal
N. Madani
A. Zekraoui
O. Kerkeb
机构
[1] Service de Réanimation Médicale,
[2] Hôpital Avicenne,undefined
[3] B P 1005,undefined
[4] 10001 Rabat,undefined
[5] Morocco Tel.: + 2 12 (1) 22 47 37 Fax: + 2 12 (7) 67 58 56,undefined
来源
Intensive Care Medicine | 1999年 / 25卷
关键词
Key words Weaning; Mechanical ventilation; Extubation outcome; Logistic models; Receiver operating characteristic curve;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: To develop a model able to determine the right time for extubation and to validate its performance.¶Design: A prospective clinical study.¶Setting: 14-bed medical intensive care unit in a university hospital.¶Patients: 101 patients (37 women/64 men) ventilated over more than 48 h (mean 10.4 ± 10.3 days) and considered ready to be weaned by the medical team (February 1996–February 1998).¶Methods: This study included two series: a development series with 53 patients and a validation series with 48 patients. Before extubation, a weaning test was performed measuring tidal volume (VT), respiratory rate (f), f/VT ratio, minute ventilation, vital capacity (VC) and maximum inspiratory and expiratory pressures (MIP and MEP). The success of extubation was assessed after 48 h. Receiver operating characteristic (ROC) curves allowed the analysis of the discriminating power of each parameter. Threshold values were determined using the Youden's index. To create the best predictive model, we performed a multiple logistic regression analysis. To assess the calibration and the discrimination of the model, the Hosmer-¶Lemeshow goodness-of-fit test and area under ROC curves (AUC) were adopted.¶Measurements and results: In a development series, 60 tests were carried out with 38 successful extubations and 22 extubation failures. The multivariate analysis found three significant variables: VC (threshold value = 635 ml), f/VT ratio (threshold value = 88 breaths/min.l) and MEP (threshold value = 28 cmH2O). The validation cohort included 59 tests (38 successes and 21 failures). The validation series shows a good discrimination (AUC = 0.855 ± 0.059) and calibration (goodness-of-fit test C: p = 0.224) of the model.¶Conclusion: VC together with the ¶f/VT ratio and MEP offer accurate prediction of early extubation.
引用
收藏
页码:1077 / 1083
页数:6
相关论文
共 50 条
  • [21] Weaning from mechanical ventilation
    Hendra, KP
    Celli, BR
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1999, 37 (03) : 127 - 143
  • [22] Weaning from mechanical ventilation
    Inmaculada Alía
    Andrés Esteban
    Critical Care, 4
  • [23] Weaning from mechanical ventilation
    Moonsie, I
    Davidson, C
    CLINICAL MEDICINE, 2005, 5 (05) : 445 - 448
  • [24] Weaning from Mechanical Ventilation
    Shaikh, Hameeda
    Morales, Daniel
    Laghi, Franco
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 35 (04) : 451 - 468
  • [25] Weaning from mechanical ventilation
    Dongelmans, D. A.
    NETHERLANDS JOURNAL OF CRITICAL CARE, 2010, 14 (03): : 178 - 179
  • [26] Weaning from mechanical ventilation
    Lermitte, Jeremy
    Garfield, Mark J.
    BJA EDUCATION, 2005, 5 (04) : 113 - 117
  • [27] WEANING FROM MECHANICAL VENTILATION
    TOBIN, MJ
    JUBRAN, A
    MATHRU, M
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 1992, 4 (04): : 279 - 286
  • [28] Weaning from mechanical ventilation
    Eskandar, Nizar
    Apostolakos, Michael J.
    CRITICAL CARE CLINICS, 2007, 23 (02) : 263 - +
  • [29] Weaning from mechanical ventilation
    BouAkl, Imad
    Bou-Khalil, Pierre
    Kanazi, Ghassan
    Ayoub, Chakib
    El-Khatib, Mohamad
    CURRENT OPINION IN ANESTHESIOLOGY, 2012, 25 (01) : 42 - 47
  • [30] WEANING FROM MECHANICAL VENTILATION
    SAHN, SA
    LAKSHMINARAYAN, S
    PETTY, TL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 235 (20): : 2208 - 2212