Fouling in reverse osmosis (RO) membrane in water recovery from secondary effluent: a review

被引:0
|
作者
Santosh Raj Pandey
Veeriah Jegatheesan
Kanagaratnam Baskaran
Li Shu
机构
[1] Deakin University,School of Engineering
关键词
Reverse osmosis; Secondary effluent; Water recovery; Potential fouling water quality parameters; Membrane fouling; Pre-treatments;
D O I
暂无
中图分类号
学科分类号
摘要
Reverse osmosis (RO) is the most preferable process for water recovery from secondary effluent (SE) because of its higher rejection of impurities with lower associated cost and higher quality of product. Fouling still is a major challenge during the water recovery due to higher contaminant loadings in SE and high rejection capability of this membrane. The presence of suspended solids, colloidal and organic matters, and high level of biological activities in SE further elevate fouling potentiality. This review was performed to identify major foulants causing hindrance in sustainable application of reverse osmosis and to present available pre-treatment options for these foulants. There are four fouling types present in RO namely; bio-fouling, inorganic/scaling, organic, and particulate fouling. Among them; bio-fouling is less understood but dominant since the pre-treatment options are not well developed. Other fouling mechanisms have been overcome by well developed pre-treatments. The major foulants for RO are dissolved and macromolecular organic substances, sparingly soluble inorganic compounds, colloidal and suspended particles, and micro-organisms. Some of these potential fouling water quality parameters (PFWQPs) are interrelated with each others such as electrical conductivity is a surrogate measure of total dissolved solids with established stable relationship. Most of these PFWQPs such as total suspended solids, turbidity, chemical oxygen demand can be removed by conventional pre-treatment; some such as colloidal particles and micro-organisms by modern options and even others such as endocrine disrupting compounds, pharmaceutical and personal care products are still challenging for current pre-treatments. These foulants need to be identified properly to integrate appropriate pre-treatments for minimizing fouling potentiality to increase water recovery at minimal costs.
引用
收藏
页码:125 / 145
页数:20
相关论文
共 50 条
  • [31] Change in membrane performance due to organic fouling in nanofiltration (NF)/reverse osmosis (RO) applications
    Agenson, Kenneth O.
    Urase, Taro
    SEPARATION AND PURIFICATION TECHNOLOGY, 2007, 55 (02) : 147 - 156
  • [32] Improving the water flux and bio-fouling resistance of reverse osmosis (RO) membrane through surface modification by zwitterionic polymer
    Wang, Jing
    Wang, Zhi
    Wang, Jixiao
    Wang, Shichang
    JOURNAL OF MEMBRANE SCIENCE, 2015, 493 : 188 - 199
  • [33] Modeling organic fouling of reverse osmosis membrane: From adsorption to fouling layer formation
    Li, Haigang
    Xia, Huanjin
    Mei, Yingxin
    DESALINATION, 2016, 386 : 25 - 31
  • [34] Review of Disposal of Concentrate Streams from Nanofiltration (NF) or Reverse Osmosis (RO) Membrane Process
    Li, Xinyang
    Zhang, Liwei
    Wang, Chengwen
    ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 3470 - 3475
  • [35] Removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant
    Liu, Jianwei
    Zhao, Mengfei
    Duan, Cui
    Yue, Peng
    Li, Tinggang
    WATER SCIENCE AND TECHNOLOGY, 2021, 83 (03) : 689 - 700
  • [36] Organic matter removal from a membrane bioreactor effluent for reverse osmosis fouling mitigation by microgranular adsorptive filtration system
    Chun, Youngpil
    Hua, Tao
    Anantharaman, Aditya
    Chew, Jia Wei
    Cai, Nathan
    Benjamin, Mark
    Wang, Rong
    DESALINATION, 2021, 506
  • [37] Impact of polyacrylamide residue on reverse osmosis membrane fouling in mine water treatment
    Guo Z.
    Mao W.
    Xiao Y.
    Zheng P.
    Ma S.
    Meitan Xuebao/Journal of the China Coal Society, 2020, 45 : 986 - 992
  • [38] Fouling effect on Reverse Osmosis (RO) membranes performance in desalination plant
    Shouman, Loula A.
    Afify, Ramadan M.
    Fadel, Dalia A.
    Esawy, Mohamed H.
    DESALINATION AND WATER TREATMENT, 2024, 319
  • [39] Fouling and fouling mitigation in batch reverse osmosis: review and outlook
    Burlace, L.
    Davies, P. A.
    DESALINATION AND WATER TREATMENT, 2022, 249 : 1 - 22
  • [40] Effect of Electric Field on Membrane Fouling and Membrane Performance in Reverse Osmosis Treatment of Brackish Water
    Fu, Caixia
    Yi, Xuenong
    Gao, Yuqiong
    APPLIED SCIENCES-BASEL, 2024, 14 (02):