Rapid SPME/LC/MS/MS Analysis of N-Methylcarbamate Pesticides in Water

被引:0
|
作者
D. A. Volmer
J. P. M. Hui
机构
[1] Institute for Marine Biosciences,
[2] National Research Council,undefined
[3] 1411 Oxford Street,undefined
[4] Halifax,undefined
[5] Nova Scotia B3H 3Z1,undefined
[6] Canada ,undefined
关键词
Mass Spectrometry; Drinking Water; Ionic Strength; Tandem Mass; Tandem Mass Spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
Solid-phase microextraction combined with fast short-column liquid chromatography/electrospray ionization tandem mass spectrometry (SPME/LC/MS/MS) was used for isolating and analyzing nine N-methylcarbamate pesticides from water samples. Several SPME parameters, such as polarity of fibers, extraction time, and effect of ionic strength, were investigated and their impact on the SPME/LC/MS/MS technique was studied. The method was shown to be sensitive with detection limits between 0.3 and 1.9 μg/L and reproducible with precision between 4.5 and 12.7% RSD. The versatility of the method was exhibited by its excellent linearity in the concentration range of 2–2,000 μg/L in drinking water. A comparison of the SPME/LC/MS/MS method with LC/MS/MS methods utilizing traditional sample preparation techniques shows that the former offers similar performance in terms of precision and linearity, but is clearly easier to use and faster to perform.
引用
收藏
页码:1 / 7
页数:6
相关论文
共 50 条
  • [41] Simple and Rapid Determination of Benzoylphenylurea Pesticides in River Water and Vegetables by LC–ESI-MS
    Dolores Barranco Martínez
    María Martínez Galera
    Piedad Parrilla Vázquez
    M. Dolores Gil García
    Chromatographia, 2007, 66 : 533 - 538
  • [42] Simple and rapid determination of benzoylphenylurea pesticides in river water and vegetables by LC-ESI-MS
    Martinez, Dolores Barranco
    Galera, Maria Martinez
    Vazquez, Pieclad Parrilla
    Garcia, M. Dolores Gil
    CHROMATOGRAPHIA, 2007, 66 (7-8) : 533 - 538
  • [43] A new strategy for the chemiluminescent screening analysis of total N-methylcarbamate content in water
    Soto-Chinchilla, JJ
    Gámiz-Gracia, L
    García-Campaña, AM
    Cuadros-Rodríguez, L
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 113 - 118
  • [44] Determination of N-methylcarbamate pesticides using flow injection with photoinduced chemiluminescence detection
    Lopez-Paz, Jose Luis
    Catala-Icardo, Monica
    Langa-Sanchez, Adrian
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (06) : 606 - 617
  • [45] Determination of adrenolytic drugs by SPME–LC–MS
    Boguslaw Buszewski
    Pawel Olszowy
    Tomasz Ligor
    Malgorzata Szultka
    Jacek Nowaczyk
    Maciej Jaworski
    Marek Jackowski
    Analytical and Bioanalytical Chemistry, 2010, 397 : 173 - 179
  • [46] Rapid LC-MS-MS Analysis of Heterocyclic Amines in Salmon
    Lomas, Simon
    Layne, Jeff
    LC GC EUROPE, 2012, : 9 - 9
  • [47] Rapid LC-MS-MS Analysis of Heterocyclic Amines in Salmon
    Lomas, Simon
    Layne, Jeff
    LC GC NORTH AMERICA, 2012, : 27 - 27
  • [48] Analysis of Microcystins in Drinking Water by ELISA and LC/MS/MS
    Guo, Yingbo C.
    Lee, Anthea K.
    Yates, Richard S.
    Liang, Sun
    Rochelle, Paul A.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2017, 109 (03): : 13 - 25
  • [49] Bottled water: Analysis of mycotoxins by LC-MS/MS
    Mata, A. T.
    Ferreira, J. P.
    Oliveira, B. R.
    Batoreu, M. C.
    Crespo, M. T. Barreto
    Pereira, V. J.
    Bronze, M. R.
    FOOD CHEMISTRY, 2015, 176 : 455 - 464
  • [50] Analysis of perchlorate in water and soil by electrospray LC/MS/MS
    Winkler, P
    Minteer, M
    Willey, J
    ANALYTICAL CHEMISTRY, 2004, 76 (02) : 469 - 473