Estimation of ambient and non-ambient components of particulate matter exposure from a personal monitoring panel study

被引:0
|
作者
William E Wilson
Michael Brauer
机构
[1] National Center for Environmental Assessment,
[2] U.S. Environmental Protection Agency,undefined
[3] School of Occupational and Environmental Hygiene,undefined
[4] The University of British Columbia,undefined
关键词
panel study; particulate matter; personal exposure; ambient concentration; ambient exposure; nonambient exposure;
D O I
暂无
中图分类号
学科分类号
摘要
To provide additional insight into factors affecting exposure to airborne particulate matter and the resultant health effects, we developed a method to estimate the ambient and nonambient components of total personal exposure. The ambient (or outdoor) component of total personal exposure to particulate matter (PM) (called ambient exposure) includes exposure to the ambient PM concentration while outdoors and exposure while indoors to ambient PM that has infiltrated indoors. The nonambient component of total personal exposure to PM (called nonambient exposure) refers to exposure to PM generated by indoor sources and an individual's personal activity. We used data collected from a personal monitoring study in Vancouver, Canada to demonstrate the methodology. In this study, ambient PM2.5 exposure was 71% of the measured ambient PM2.5 concentration and was responsible for 44% of the measured total personal PM2.5 exposure. Regression analysis of the pooled data sets for ambient and total exposure against outdoor concentrations yielded similar slopes (0.76 for ambient and 0.77 for total) but a higher coefficient of determination for ambient exposure (R2=0.62) than for total exposure (R2=0.072). As expected, the nonambient exposure was not related to the ambient concentration (R2<10−6). For longitudinal analyses of the relationship between measured personal exposure and ambient concentrations for individual subjects, the correlation of total personal exposure with ambient concentration yielded values of Pearson's r from 0.83 to −0.68 with an average of 0.36. The relationship was statistically significant for only five of the 16 subjects. In contrast, the correlation of the estimated ambient exposure with ambient concentration yielded values of Pearson's r from 0.92 to 0.77 with an average of 0.88; 14 were significant. An example, taken from an epidemiologic analysis using the exposure data from this paper, demonstrates the usefulness of separating total exposure into its ambient and nonambient components.
引用
收藏
页码:264 / 274
页数:10
相关论文
共 50 条
  • [31] Association of Ambient Particulate Matter Exposure with the Incidence of Glaucoma in Childhood
    Min, Kyoung-Bok
    Min, Jin-Young
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 211 : 176 - 182
  • [32] The 1998 Baltimore Particulate Matter Epidemiology–Exposure Study: Part 1. Comparison of ambient, residential outdoor, indoor and apartment particulate matter monitoring
    RON WILLIAMS
    JACK SUGGS
    R ZWEIDINGER
    GARY EVANS
    JOHN CREASON
    RICHARD KWOK
    CHARLES RODES
    PHIL LAWLESS
    LINDA SHELDON
    Journal of Exposure Science & Environmental Epidemiology, 2000, 10 : 518 - 532
  • [33] Personal exposure to fine particulate matter and renal function in children: A panel study
    Liu, Miao
    Guo, Wenting
    Cai, Yunyao
    Yang, Huihua
    Li, Wenze
    Yang, Liangle
    Lai, Xuefeng
    Fang, Qin
    Ma, Lin
    Zhu, Rui
    Zhang, Xiaomin
    ENVIRONMENTAL POLLUTION, 2020, 266
  • [34] Total personal exposure to fine particulate matter in an urban adult population:: the role of ambient air and transport
    Boudet, C
    Dechénaux, J
    Balducci, F
    Masclet, P
    Zmirou, D
    INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 1998, 20 (1-4) : 30 - 38
  • [35] Estimating separately personal exposure to ambient and nonambient particulate matter for epidemiology and risk assessment: Why and how
    Wilson, WE
    Mage, DT
    Grant, LD
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (07) : 1167 - 1183
  • [36] Personal exposure to particulate matter in peri-urban India: predictors and association with ambient concentration at residence
    Sanchez, Margaux
    Mila, Carles
    Sreekanth, V
    Balakrishnan, Kalpana
    Sambandam, Sankar
    Nieuwenhuijsen, Mark
    Kinra, Sanjay
    Marshall, Julian D.
    Tonne, Cathryn
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2020, 30 (04) : 596 - 605
  • [37] Personal exposure to particulate matter in peri-urban India: predictors and association with ambient concentration at residence
    Margaux Sanchez
    Carles Milà
    V. Sreekanth
    Kalpana Balakrishnan
    Sankar Sambandam
    Mark Nieuwenhuijsen
    Sanjay Kinra
    Julian D. Marshall
    Cathryn Tonne
    Journal of Exposure Science & Environmental Epidemiology, 2020, 30 : 596 - 605
  • [38] A comprehensive particulate matter monitoring system and dosimetry-based ambient particulate matter standards
    Zeng, YS
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2006, 56 (04): : 518 - 529
  • [39] Ambient fine particulate matter exposure and cardiovascular mortality in China: a prospective cohort study
    Yin, Peng
    Brauer, Michael
    Cohen, Aaron
    Burnett, Richard T.
    Liu, Jiangmei
    Liu, Yunning
    Zhou, Maigeng
    LANCET, 2015, 386 : 6 - 6
  • [40] Exposure to ambient particulate matter affects semen quality: A case study in Wenzhou, China
    Dai, Xuchao
    Chen, Gang
    Zhang, Mengqi
    Mei, Kun
    Liu, Yanlong
    Ding, Cheng
    Chang, Yanxiang
    Wu, Zhigang
    Huang, Hong
    ANDROLOGY, 2023, 11 (03) : 444 - 455