Rectal tumour staging: MR imaging using pelvic phased-array and endorectal coils vs endoscopic ultrasonography

被引:0
|
作者
L. Blomqvist
M. Machado
C. Rubio
N. Gabrielsson
S. Granqvist
S. Goldman
T. Holm
机构
[1] Department of Diagnostic Radiology Karolinska Hospital,
[2] S-171 76 Stockholm,undefined
[3] Sweden,undefined
[4] Department of Surgery,undefined
[5] Ersta Hospital,undefined
[6] Sweden,undefined
[7] Department of Pathology Karolinska Hospital,undefined
[8] S-171 76 Stockholm,undefined
[9] Sweden,undefined
[10] Department of Diagnostic Radiology Ersta Hospital,undefined
[11] Sweden,undefined
[12] Department of Surgery Karolinska Hospital,undefined
[13] S-171 76 Stockholm,undefined
[14] Sweden,undefined
来源
European Radiology | 2000年 / 10卷
关键词
Key words: Rectum – Neoplasms – MR imaging – Ultrasonography – Comparative studies;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to compare MR imaging and endoscopic ultrasonography (EUS) for the local staging of rectal tumours. Forty-nine patients were examined on a 1.5-T MR unit using either a pelvic phased-array coil (n = 37) alone or combined with an endorectal coil (n = 12). Sagittal and axial sequences with T2-weighted fast spin-echo and axial T1-weighted spin-echo techniques were employed. The EUS technique was performed using a flexible endosonoscope. The results were compared with findings at histopathological sectioning of the specimen. The T-stage on MR correlated with histopathology in 32 of 49 patients and on EUS in 29 of 49 patients. The N-stage on MR correlated with histopathology in 22 of 49 patients and on EUS in 26 of 49 patients. Tumour penetration of the rectal wall was predicted by MR with 86 % sensitivity and 65 % specificity, and by EUS with 89 % sensitivity and 33 % specificity. Preoperative radiotherapy was administered to 40 of the patients after the examinations which may explain some of the overstaging by MR and EUS. Three patients with surgically and histopathologically confirmed invasion of neighbouring organs in the pelvis were detected preoperatively on MR but none on EUS. Tumour penetration of the rectal wall and local lymph node metastases cannot accurately be predicted with MR or EUS. Magnetic resonance, however, seems to be more useful for preoperative identification of clinically occult advanced disease.
引用
收藏
页码:653 / 660
页数:7
相关论文
共 50 条
  • [21] 3 Tesla magnetic resonance Imaging of the prostate with combined pelvic phased-array and endorectal coils: Initial experience
    Bloch, BN
    Rofsky, NM
    Baroni, RH
    Marquis, RP
    Pedrosa, I
    Lenkinski, RE
    ACADEMIC RADIOLOGY, 2004, 11 (08) : 863 - 867
  • [22] Effect of using endorectal coil in preoperative staging of rectal carcinomas by pelvic MR imaging
    Donmez, Fuldem Yildirim
    Tunaci, Mehtap
    Yekeler, Ensar
    Balik, Emre
    Tunaci, Atadan
    Acunas, Gulden
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (01) : 139 - 145
  • [23] Endorectal MR imaging and ultrasonography of rectal tumours: Correlation with pathologic staging.
    Heindel, W
    Gossmann, A
    Ernst, S
    Schafer, H
    Kugel, H
    Krug, B
    Selzner, M
    Krahe, T
    Lackner, K
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (06): : 573 - 579
  • [24] External phased-array MR imaging preoperative assessment of rectal cancer
    Hoeffel, C.
    Marra, M. D.
    Azizi, L.
    Van, K. Tran
    Crema, M. D.
    Lewin, M.
    Arrive, L.
    Tubiana, J. M.
    JOURNAL DE RADIOLOGIE, 2006, 87 (12): : 1821 - 1830
  • [25] Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer
    Kim, Bum Soo
    Kim, Tae-Hwan
    Kwon, Tae Gyun
    Yoo, Eun Sang
    YONSEI MEDICAL JOURNAL, 2012, 53 (03) : 550 - 556
  • [26] Magnetic resonance imaging of prostate cancer: Comparison of image quality using endorectal and pelvic phased array coils
    Husband, JE
    Padhani, AR
    Macvicar, AD
    Revell, P
    CLINICAL RADIOLOGY, 1998, 53 (09) : 673 - 681
  • [27] PULMONARY VASCULATURE - SINGLE BREATH-HOLD MR IMAGING WITH PHASED-ARRAY COILS
    FOO, TKF
    MACFALL, JR
    HAYES, CE
    SOSTMAN, HD
    SLAYMAN, BE
    RADIOLOGY, 1992, 183 (02) : 473 - 477
  • [28] Pelvic phased-array MR imaging of anal carcinoma before and after chemoradiation
    Koh, D. M.
    Dzik-Jurasz, A.
    O'Neill, B.
    Tait, D.
    Husband, J. E.
    Brown, G.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (962): : 91 - 98
  • [29] Accuracy of Thin-Section Magnetic Resonance Imaging With a Pelvic Phased-Array Coil in the Local Staging of Rectal Cancer
    Halefoglu, Ahmet Mesrur
    Atasoy, Serpil Topuz
    Sakiz, Damlanur
    Baykan, Adil
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 58 - 64
  • [30] PREDICTIVE VALUE OF COMBINED ENDORECTAL AND PHASED-ARRAY COIL MR-IMAGING IN LOCAL STAGING OF PROSTATE CARCINOMA - MULTIVARIATE FEATURE ANALYSIS
    ALAGAPPAN, R
    HRICAK, H
    YU, KK
    CHERNOFF, DM
    KALBHEN, CL
    CHEN, M
    RADIOLOGY, 1995, 197 : 253 - 253