Error analysis of a natural breathing calibration method for respiratory inductive plethysmography

被引:0
|
作者
N. O. T. Strömberg
机构
[1] Liköping University,Department of Biomedical Engineering
来源
Medical and Biological Engineering and Computing | 2001年 / 39卷
关键词
Non-invasive; Respiratory monitoring; Respiratory inductive plethysmography; Calibration;
D O I
暂无
中图分类号
学科分类号
摘要
Respiratory volumes are measured non-invasively by recording rib cage and abdominal motions using respiratory inductive plethysmography (RIP). Qualitative diagnostic calibration (QDC) of RIP is based on the natural variability in the relative rib-cage-to-abdomen contribution during tidal breathing. QDC does not require subject cooperation but it has previously been shown that accuracy may deteriorate when breathing pattern changes. The aim of this study was to investigate the causes and situations where QDC accuracy deteriorates. The QDC method was compared to PRA (calibration during voluntarily preferential rib cage or abdomen breathing) in ten adults. A reference RIP calibration was obtained from all validation data (REF). The PRA method had better accuracy than the QDC method (p<0.01). The volumetric error ranged between 10% and 136% with QDC and between 5% and 33% with PRA. The PRA calibration factors were within 6% of those from REF, while the QDC rib-cage factor was underestimated by 15% and the abdominal factor was overestimated by 38%. Small natural variability in the relative rib-cage-to-abdomen contribution was related to poor accuracy. Each compartment's variability depended on its magnitude, which is a violation of the QDC assumptions.
引用
收藏
页码:310 / 314
页数:4
相关论文
共 50 条
  • [31] Breathing pattern recordings using respiratory inductive plethysmography, before and after a physiotherapy breathing retraining program for asthma: A case report
    Tehrany, Rokhsaneh
    DeVos, Ruth
    Bruton, Anne
    PHYSIOTHERAPY THEORY AND PRACTICE, 2018, 34 (04) : 329 - 335
  • [32] BREATHING PATTERNS IN LAMBS AFTER OLEIC-ACID LUNG INJURY UTILIZING RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    WARREN, RH
    ALDERSON, SH
    CRITICAL CARE MEDICINE, 1990, 18 (01) : 92 - 96
  • [33] Respiratory inductive plethysmography for noninvasive cardio-respiratory monitoring
    Abdulhay, E.
    Calabrese, P.
    Fontecave-Jallon, J.
    Gumery, P.
    Baconnier, P.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2011, 25 : 46 - 46
  • [34] Respiratory inductive plethysmography to assess respiratory variability and complexity in humans
    Fiamma, Marie-Noelle
    Samara, Ziyad
    Baconnier, Pierre
    Similowski, Thomas
    Straus, Christian
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2007, 156 (02) : 234 - 239
  • [35] VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN CHRONIC AIRWAYS OBSTRUCTION
    TOBIN, MJ
    JENOURI, G
    WATSON, H
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 125 (04): : 122 - 122
  • [36] Evaluation of Respiratory Inductive Plethysmography in VLBW infants 1709
    Gabriel Musante
    Nelson Claure
    Tilo Gerhardt
    Ruth Everett
    Eduardo Bancalari
    Pediatric Research, 1998, 43 (Suppl 4) : 291 - 291
  • [37] EVALUATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN THE MEASUREMENT OF BREATHING PATTERN AND PEEP-INDUCED CHANGES IN LUNG-VOLUME
    VALTA, P
    TAKALA, J
    FOSTER, R
    WEISSMAN, C
    KINNEY, JM
    CHEST, 1992, 102 (01) : 234 - 238
  • [38] Respiratory function parameters in infants using inductive plethysmography
    Selbie, RD
    Fletcher, M
    Arestis, N
    White, R
    Duncan, A
    Helms, P
    Duffty, P
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (06) : 501 - 511
  • [39] VALIDATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY WITH CHANGE IN BODY POSTURE
    CHADHA, TS
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 128 (02): : 331 - 331
  • [40] Detection of speaking with a new respiratory inductive plethysmography system
    Wilhelm, FH