Error analysis of a natural breathing calibration method for respiratory inductive plethysmography

被引:0
|
作者
N. O. T. Strömberg
机构
[1] Liköping University,Department of Biomedical Engineering
关键词
Non-invasive; Respiratory monitoring; Respiratory inductive plethysmography; Calibration;
D O I
暂无
中图分类号
学科分类号
摘要
Respiratory volumes are measured non-invasively by recording rib cage and abdominal motions using respiratory inductive plethysmography (RIP). Qualitative diagnostic calibration (QDC) of RIP is based on the natural variability in the relative rib-cage-to-abdomen contribution during tidal breathing. QDC does not require subject cooperation but it has previously been shown that accuracy may deteriorate when breathing pattern changes. The aim of this study was to investigate the causes and situations where QDC accuracy deteriorates. The QDC method was compared to PRA (calibration during voluntarily preferential rib cage or abdomen breathing) in ten adults. A reference RIP calibration was obtained from all validation data (REF). The PRA method had better accuracy than the QDC method (p<0.01). The volumetric error ranged between 10% and 136% with QDC and between 5% and 33% with PRA. The PRA calibration factors were within 6% of those from REF, while the QDC rib-cage factor was underestimated by 15% and the abdominal factor was overestimated by 38%. Small natural variability in the relative rib-cage-to-abdomen contribution was related to poor accuracy. Each compartment's variability depended on its magnitude, which is a violation of the QDC assumptions.
引用
收藏
页码:310 / 314
页数:4
相关论文
共 50 条
  • [1] Error analysis of a natural breathing calibration method for respiratory inductive plethysmography
    Strömberg, NOT
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (03) : 310 - 314
  • [2] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY IN SPONTANEOUSLY BREATHING LAMBS AND PIGLETS
    WARREN, RH
    ALDERSON, SH
    JOURNAL OF DEVELOPMENTAL PHYSIOLOGY, 1986, 8 (04) : 255 - 258
  • [3] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPH DURING NATURAL BREATHING
    SACKNER, MA
    WATSON, H
    BELSITO, AS
    FEINERMAN, D
    SUAREZ, M
    GONZALEZ, G
    BIZOUSKY, F
    KRIEGER, B
    JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (01) : 410 - 420
  • [4] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY (RESPICOMPTM) IN INFANTS
    WARREN, RH
    ALDERSON, SH
    CLINICAL RESEARCH, 1984, 32 (05): : A909 - A909
  • [5] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY (RESPICOMP) IN LAMBS
    WARREN, RH
    FEWELL, JE
    ALDERSON, SH
    CLINICAL RESEARCH, 1983, 31 (05): : A917 - A917
  • [6] BREATHING PATTERNS IN INFANTS UTILIZING RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    WARREN, RH
    ALDERSON, SH
    CHEST, 1986, 89 (05) : 717 - 722
  • [7] BREATHING PATTERNS IN LAMBS UTILIZING RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY
    WARREN, RH
    ALDERSON, SH
    PEDIATRIC RESEARCH, 1990, 27 (04) : A321 - A321
  • [8] ACCURACY OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY DURING LOADED BREATHING
    MADOR, MJ
    GUENTHER, SM
    PEREZ, W
    REAGLE, R
    TOBIN, MJ
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A43 - A43
  • [9] Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography
    Wai Leung Ambrose Lo
    Dong Feng Huang
    Journal of Clinical Monitoring and Computing, 2017, 31 : 755 - 764
  • [10] Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography
    Lo, Wai Leung Ambrose
    Huang, Dong Feng
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (04) : 755 - 764