Analysis of the ear pulse oximeter waveform

被引:37
|
作者
Awad A.A. [1 ]
Stout R.G. [1 ]
Ghobashy M.A.M. [1 ]
Rezkanna H.A. [2 ]
Silverman D.G. [1 ]
Shelley K.H. [1 ]
机构
[1] Department of Anesthesia, Yale University School of Medicine, New Haven, CT 06516-8051
[2] Department of Anesthesia, Benha Faculty of Medicine, Zagazig University, Zagazig
关键词
Cardiac output; Ear pulse oximeter; Peripheral waveforms;
D O I
10.1007/s10877-006-9018-z
中图分类号
学科分类号
摘要
Objective: For years researchers have been attempting to understand the relationship between central hemodynamics and the resulting peripheral waveforms. This study is designed to further understanding of the relationship between ear pulse oximeter waveforms, finger pulse oximeter waveforms and cardiac output (CO). It is hoped that with appropriate analysis of the peripheral waveforms, clues can be gained to help to optimize cardiac performance. Methods. Part 1: Studying the effect of cold immersion test on plethysmographic waveforms. Part 2: Studying the correlation between ear and finger plethysmographic waveforms and (CO) during CABG surgery. The ear and finger plethysmographic waveforms were analyzed to determine amplitude, width, area, upstroke and downslope. The CO was measured using continuous PA catheter. Using multi-linear regr ession, ear plethysmographic waveforms, together with heart rate (HR), were used to determine the CO Agreement between the two methods of CO determination was assessed. Results. Part 1: On contralateral hand immersion, all finger plethysmographic waveforms were reduced, there was no significant change seen in ear plethysmographic waveforms, except an increase in ear plethysmographic width. Part 2: Phase1: Significant correlation detected between the ear plethysmographic width and other ear and finger plethysmographic waveforms. Phase 2: The ear plethysmographic width had a significant correlation with the HR and CO. The correlation of the other ear plethysmographic waveforms with CO and HR are summarized (Table 5). Multi-linear regression analysis was done and the best fit equation was found to be: CO = 8.084 - 14.248 × Ear width + 0.03 × HR + 92.322 × Ear down slope+0.027 × Ear Area Using Bland & Altman, the bias was (0.05 L) but the precision (2.46) is large to be clinically accepted. Conclusion. The ear is relatively immune to vasoconstrictive challenges which make ear plethysmographic waveforms a suitable monitor for central hemodynamic changes. The ear plethysmographic width has a good correlation with CO. © Springer Science+Business Media, Inc. 2006.
引用
收藏
页码:175 / 184
页数:9
相关论文
共 50 条
  • [31] The answer at our fingertips: Volume status in cirrhosis determined by machine learning and pulse oximeter waveform
    Mazumder, Nikhilesh R.
    Kazen, Avidor
    Carek, Andrew
    Etemadi, Mozziyar
    Levitsky, Josh
    PHYSIOLOGICAL REPORTS, 2022, 10 (05):
  • [32] Use of pulse oximeter plethysmograph waveform to monitor patients with acute exacerbation of obstructive airway diseases
    Khalil, Magdy Mohamed
    Sweillm, Hend Mohamed Elsayed
    Abd Elsamad, Ahmed Mohamed
    EGYPTIAN JOURNAL OF BRONCHOLOGY, 2025, 19 (01)
  • [33] What is a Pulse Oximeter?
    Journal of the Institute of Electrical Engineers of Japan, 2023, 143 (11): : 722
  • [34] Pulse oximeter plethysmograph waveform and automated oscillometric sphygmomanometer for ankle-brachial index measurement
    Arnold, Cosby G.
    Walker, J. Richard
    Metter, E. Jeffrey
    Young, Shane
    Brady, Mark F.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 40 : 162 - 165
  • [35] Evolution of the pulse oximeter
    Pole, Y
    HISTORY OF ANESTHESIA, 2002, 1242 : 137 - 144
  • [36] Automated Pulse Oximeter Waveform Analysis to Track Changes in Blood Pressure During Anesthesia Induction: A Proof-of-Concept Study
    Ghamri, Yassine
    Proenca, Martin
    Hofmann, Gregory
    Renevey, Philippe
    Bonnier, Guillaume
    Braun, Fabian
    Axis, Alexandre
    Lemay, Mathieu
    Schoettker, Patrick
    ANESTHESIA AND ANALGESIA, 2020, 130 (05): : 1222 - 1233
  • [37] Analysis of the Predictive Potential of Pulse Oximeter Data for Admission
    Dunsmuir, Dustin
    Garde, Ainara
    Zhou, Guohai
    Raihana, Shahreen
    Huda, Tanvir
    Karlen, Walter
    Dehkordi, Parastoo
    El Arifeen, Shams
    Ansermino, J. Mark
    ANESTHESIA AND ANALGESIA, 2016, 122
  • [38] EAR OXIMETER IS PRE-CALIBRATED
    LERRO, JP
    DESIGN NEWS, 1977, 33 (01) : 34 - 34
  • [39] Why do not we use finger pulse oximeter plethysmograph waveform to monitor the effectiveness of cardiopulmonary resuscitation?
    Xu, Jun
    Zhu, Huadong
    Wang, Zhong
    Yu, Xuezhong
    Walline, Joseph
    RESUSCITATION, 2011, 82 (07) : 959 - 959
  • [40] THE ANSWER AT OUR FINGERTIPS: DETERMINING VOLUME STATUS IN CIRRHOSIS USING MACHINE LEARNING AND A PULSE OXIMETER WAVEFORM
    Mazumder, Nikhilesh
    Kazen, Avidor
    Carek, Andrew
    Etemadi, Mozziyar
    Levitsky, Josh
    HEPATOLOGY, 2020, 72 : 92A - 92A