Assessment of the cardiac output at rest and during exercise stress using real-time cardiovascular magnetic resonance imaging in HFpEF-patients

被引:0
|
作者
Alexander Schulz
Hannah Mittelmeier
Lukas Wagenhofer
Sören J. Backhaus
Torben Lange
Ruben Evertz
Shelby Kutty
Johannes T. Kowallick
Gerd Hasenfuß
Andreas Schuster
机构
[1] University Medical Center Göttingen,Department of Cardiology and Pneumology
[2] Georg-August University,Institute of Biomedical Imaging
[3] German Center for Cardiovascular Research (DZHK),Department of Cardiology
[4] Partner Site Göttingen,Taussig Heart Center
[5] University of Technology Graz,Institute for Diagnostic and Interventional Radiology
[6] Campus Kerckhoff of the Justus-Liebig-University Giessen,School of Biomedical Engineering and Imaging Sciences
[7] Kerckhoff-Clinic,undefined
[8] Johns Hopkins Hospital and School of Medicine,undefined
[9] University Medical Center Göttingen University Medical Center Göttingen,undefined
[10] Georg-August University,undefined
[11] King’s College London,undefined
关键词
Exercise stress CMR; HFpEF; Real-time imaging; Cardiac output;
D O I
暂无
中图分类号
学科分类号
摘要
This methodological study aimed to validate the cardiac output (CO) measured by exercise-stress real-time phase-contrast cardiovascular magnetic resonance imaging (CMR) in patients with heart failure and preserved ejection fraction (HFpEF). 68 patients with dyspnea on exertion (NYHA ≥ II) and echocardiographic signs of diastolic dysfunction underwent rest and exercise stress right heart catheterization (RHC) and CMR within 24 h. Patients were diagnosed as overt HFpEF (pulmonary capillary wedge pressure (PCWP) ≥ 15mmHg at rest), masked HFpEF (PCWP ≥ 25mmHg during exercise stress but < 15mmHg at rest) and non-cardiac dyspnea. CO was calculated using RHC as the reference standard, and in CMR by the volumetric stroke volume, conventional phase-contrast and rest and stress real-time phase-contrast imaging. At rest, the CMR based CO showed good agreement with RHC with an ICC of 0.772 for conventional phase-contrast, and 0.872 for real-time phase-contrast measurements. During exercise stress, the agreement of real-time CMR and RHC was good with an ICC of 0.805. Real-time measurements underestimated the CO at rest (Bias:0.71 L/min) and during exercise stress (Bias:1.4 L/min). Patients with overt HFpEF had a significantly lower cardiac index compared to patients with masked HFpEF and with non-cardiac dyspnea during exercise stress, but not at rest. Real-time phase-contrast CO can be assessed with good agreement with the invasive reference standard at rest and during exercise stress. While moderate underestimation of the CO needs to be considered with non-invasive testing, the CO using real-time CMR provides useful clinical information and could help to avoid unnecessary invasive procedures in HFpEF patients.
引用
收藏
页码:853 / 862
页数:9
相关论文
共 50 条
  • [31] Comparison of real-time imaging cardiac magnetic resonance for left ventricular volumes with conventional imaging in patients with atrial fibrillation: Is real-time required?
    Costa, SP
    Yeon, SB
    Kissinger, KV
    Chuang, MC
    Manning, WJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 436A - 437A
  • [32] Comprehensive cardiovascular assessment of children with chronic kidney disease using exercise cardiac magnetic resonance imaging
    Mun Cheang
    Nathaniel J Barber
    Jennifer A Steeden
    Grzegorz T Kowalik
    Kjell Tullus
    Daljit Hothi
    Vivek Muthurangu
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [33] Cardiovascular magnetic resonance imaging for the assessment of cardiac inflammation and injury following prolonged exercise
    Rory O' Hanlon
    Gregory P Whyte
    Gillan Smith
    Francisco Alpendurada
    Joyce Wong
    Matthew Wilsonl
    David Oxborough
    Richard Godfrey
    Keith George
    Annette Dahl
    David Gaze
    Dudley J Pennell
    Sanjay K Prasad
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [34] Continuous assessment of cardiac output during exercise using real time flow with fast GPU reconstruction
    Grzegorz T Kowalik
    Jennifer A Steeden
    Bejal Pandya
    David Atkinson
    Andrew M Taylor
    Vivek Muthurangu
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [35] Dynamic bicycle exercise to assess cardiac output at multiple exercise levels during magnetic resonance imaging
    Heiberg, Johan
    Asschenfeldt, Benjamin
    Maagaard, Marie
    Ringgaard, Steffen
    CLINICAL IMAGING, 2017, 46 : 102 - 107
  • [36] Exercise CMR: real-time assessment of cardiac performance with phase contrast imaging
    Marina Quinlan
    Shareen Jaijee
    Antonio de Marvao
    Pawel F Tokarczuk
    J Simon R Gibbs
    Declan O'Regan
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [37] Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients
    Julius Traber
    Lennart Wurche
    Matthias A. Dieringer
    Wolfgang Utz
    Florian von Knobelsdorff-Brenkenhoff
    Andreas Greiser
    Ning Jin
    Jeanette Schulz-Menger
    European Radiology, 2016, 26 : 986 - 996
  • [38] Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients
    Traber, Julius
    Wurche, Lennart
    Dieringer, Matthias A.
    Utz, Wolfgang
    von Knobelsdorff-Brenkenhoff, Florian
    Greiser, Andreas
    Jin, Ning
    Schulz-Menger, Jeanette
    EUROPEAN RADIOLOGY, 2016, 26 (04) : 986 - 996
  • [39] Real-Time Cine and Myocardial Perfusion With Treadmill Stress Cardiac Magnetic Resonance in Patients Referred for Stress SPECT
    Raman, Subha V.
    Jekic, Mihaela
    Dickerson, Jennifer A.
    Foster, Eric L.
    Simonetti, Orlando P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A302 - A302
  • [40] Visualization of cardiac myxoma mobility with real-time spiral magnetic resonance imaging
    Spuentrup, E
    Kuehl, HP
    Wall, A
    Heer, C
    Buecker, A
    CIRCULATION, 2001, 104 (19) : E101 - E101