The influence of thermal aging on absorption phenomena in cross-linked polyethylene cable insulation

被引:0
|
作者
M. E. Borisova
Yu. K. Osina
机构
[1] Peter the Great St. Petersburg Polytechnic University,
来源
Technical Physics Letters | 2017年 / 43卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Absorption-controlled charge and discharge currents in cross-linked polyethylene (XPE) cable insulation before and after thermal aging have been measured. The experimental dependences were analyzed in terms of the equivalent Voigt scheme. Known parameters of the Voigt scheme were used to calculate the frequency dependences of relative dielectric permittivity, loss factor, and loss tangent of XPE films in the region of low frequencies (ω = 10–3–1 s–1) at high temperatures. Results of analysis of the absorption characteristics of XPE were applied to modeling of the process of thermal aging of cable insulation.
引用
收藏
页码:136 / 138
页数:2
相关论文
共 50 条
  • [41] AGING OF POLYETHYLENE FOR CABLE INSULATION
    GRZYBOWSKI, S
    RAKOWSKA, A
    THOMPSON, JE
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (06): : 729 - 734
  • [42] Cross-linked polyethylene - The unparalleled cable insulating material
    Peschke, EF
    Kammel, G
    Keiling, C
    SIEMENS REVIEW, 1996, : 23 - 26
  • [43] HPLC CALIBRATIONS FOR ANALYSIS OF ADDITIVES IN CROSS-LINKED CABLE INSULATION
    BAKER, MT
    JOHNSON, JF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 52 - PMSE
  • [44] Correlation between antioxidant depletion kinetic model and ageing behaviour of cross-linked polyethylene cable insulation
    Zheng, Yingying
    Long, Yiwei
    Yi, Delun
    Zhang, Haoran
    Gao, Jian
    Wu, Kangning
    Li, Jianying
    HIGH VOLTAGE, 2023, 8 (02) : 231 - 238
  • [45] Electric Field Assist on Enhancing the Electrical Breakdown Strength of Cross-Linked Polyethylene for Power Cable Insulation
    Li, Yongjun
    Han, Yongsen
    Pang, Jinjiang
    Jin, Di
    Sun, Yunlong
    Li, Zhonghua
    MACROMOLECULES, 2024, 57 (11) : 5497 - 5506
  • [46] INFLUENCE OF COPPER ON THE THERMAL-OXIDATION STABILITY OF CROSS-LINKED POLYETHYLENE
    VONGENTZKOW, W
    PIEPER, D
    SIEMENS FORSCHUNGS-UND ENTWICKLUNGSBERICHTE-SIEMENS RESEARCH AND DEVELOPMENT REPORTS, 1979, 8 (06): : 309 - 312
  • [47] Gradient Changing Morphology Research of Cross-linked Polyethylene Thick Insulation of 110 kV Power Cable
    朱爱荣
    刘英
    曹晓珑
    Journal of DongHua University, 2006, (03) : 27 - 32
  • [48] Accelerated aging of cross-linked polyethylene (XLPE and TR XLPE) cable insulations in wet conditions
    Nikolajevic, SV
    Kostoski, DD
    1998 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 1998, : 694 - 697
  • [49] THE INFLUENCE OF CURE METHOD ON THE SOL CONTENT AND PHYSICAL STRUCTURE OF CROSS-LINKED POLYETHYLENE INSULATION
    PHILLIPS, PJ
    VATANSEVER, A
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (04): : 365 - 372
  • [50] DISCUSSION OF ACCELERATED AGING TESTS OF 69-KV CROSS-LINKED POLYETHYLENE CABLE AND JOINTS
    BLODGETT, RB
    FISHER, RG
    MCAVOY, F
    MCKEAN, AL
    BALASKA, TA
    HALPERIN, H
    MILDNER, RC
    TUZINSKI, JR
    JONES, WH
    JENSEN, DR
    WILLIAMS, JL
    ZANONA, A
    LEE, AR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1969, PA88 (02): : 164 - &