Differences in oscillometric blood pressure readings between unsupported and supported back conditions

被引:0
|
作者
Tai-xuan Wan
Yuan-hao Wu
Yan-qing Wu
Weitong Hu
Hai Su
机构
[1] Nanchang University,The Department of Cardiovascular Medicine, Second Affiliated Hospital and the Second Clinical Medical College
[2] Nanchang University,Queen Mary College of Medical College
来源
Hypertension Research | 2021年 / 44卷
关键词
Blood pressure; Back; Support; Age; Hypertension;
D O I
暂无
中图分类号
学科分类号
摘要
Appropriate body posture is important for accurate blood pressure (BP) measurement. However, the impact of an unsupported back on BP readings is currently controversial. This study included 224 subjects (18–86 years old, 54.5 ± 15.5 years old, 105 males). BP was measured with an oscillometric BP device randomly following one of two protocols for back support conditions: (1) supported–unsupported–supported–unsupported, or (2) unsupported–supported–unsupported–supported. The average of the two systolic BP (SBP) and diastolic BP (DBP) readings in the same position was recorded as the final BP value. The differences in BP between the unsupported and supported back conditions were calculated as delta BP. Moreover, the percentage variation in BP (PV) was calculated with the formula delta BP/BP with an unsupported back. Multivariable regression analysis evaluated the impact of age, sex, hypertension history and supported BP level on PV. The SBP/DBP levels measured with an unsupported back were slightly higher than those when the back was supported (132.7 ± 19.5/79.6 ± 12.9 mmHg vs. 130.3 ± 20.0/78.5 ± 14.3 mmHg), and the delta SBP (2.3 mmHg) was statistically significant. The multivariable regression analysis showed that age was a positive factor but supported SBP level as a negative factor for systolic PV, while age and supported DBP level were positive factors, but hypertension history was a negative factor for diastolic PV. For a group participant, the mean difference in oscillometric SBP/DBP in the unsupported back position was 2.3/1.0 mmHg higher than that in the supported back position.
引用
收藏
页码:528 / 532
页数:4
相关论文
共 50 条
  • [21] Measuring the level of agreement between directly measured blood pressure and pressure readings obtained with a veterinary-specific oscillometric unit in anesthetized dogs
    Acierno, Mark J.
    Fauth, Erika
    Mitchell, Mark A.
    da Cunha, Anderson
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2013, 23 (01) : 37 - 40
  • [22] Can simulators evaluate systematic differences between oscillometric non-invasive blood-pressure monitors?
    Amoore, JN
    Scott, DHT
    BLOOD PRESSURE MONITORING, 2000, 5 (02) : 81 - 89
  • [23] Factors related to the differences in blood pressure values assessed by auscultatory or oscillometric methods
    Rosa Oltra, Maria
    Vicente, Antonio
    Vicente Lozano, Jose
    Jose Forner, Maria
    Jose Fabia, Maria
    Abdilla, Noelia
    Redon, Josep
    MEDICINA CLINICA, 2006, 127 (18): : 688 - 691
  • [24] Clinical significance of differences between home and clinic systolic blood pressure readings in patients with hypertension
    Masugata, Hisashi
    Senda, Shoichi
    Inukai, Michio
    Himoto, Takashi
    Hosomi, Naohisa
    Murao, Koji
    Okada, Hiroki
    Goda, Fuminori
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (04) : 1272 - 1280
  • [25] LACK OF AGREEMENT BETWEEN OSCILLOMETRIC BLOOD PRESSURE FROM THE UPPERARM AND WRIST
    de Mey, C.
    Petrov, A.
    Pajantova, V
    Velkova, S.
    Gatchev, E.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2011, 109 : 109 - 109
  • [26] Comparison of Repeatability of Blood Pressure Measurements between Oscillometric and Auscultatory Methods
    Liu, Chengyu
    Zheng, Dingchang
    Griffiths, Clive
    Murray, Alan
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 1073 - 1076
  • [27] COMPARISON BETWEEN OSCILLOMETRIC AND AUSCULTATORY BLOOD PRESSURE MEASUREMENT IN CHILDREN AND ADOLESCENTS
    Duzova, Ali
    Baskin, Esra
    Cakar, Nilgun
    Soylemezoglu, Oguz
    Yalcinkaya, Fatos
    Hayran, Mutlu
    PEDIATRIC NEPHROLOGY, 2018, 33 (10) : 1818 - 1819
  • [28] BLOOD PRESSURE MEASUREMENT: THE WAITING TIME BETWEEN READINGS
    Vinyoles, E.
    Vera, M.
    Cecilia, M.
    Garcia-Alfaro, M.
    Fernandez-San-Martin, M.
    JOURNAL OF HYPERTENSION, 2010, 28 : E254 - E254
  • [29] Agreement between two oscillometric blood pressure technologies and invasively measured arterial pressure in the dog
    da Cunha, Anderson F.
    Ramos, Sara J.
    Domingues, Michelle
    Beaufrere, Hugues
    Shelby, Amanda
    Stout, Rhett
    Acierno, Mark J.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2016, 43 (02) : 199 - 203
  • [30] Using hybrid models to predict blood pressure reactivity to unsupported back based on anthropometric characteristics
    Kaur, Gurmanik
    Arora, Ajat Shatru
    Jain, Vijender Kumar
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2015, 16 (06) : 474 - 485