Differences in oscillometric blood pressure readings between unsupported and supported back conditions

被引:0
|
作者
Tai-xuan Wan
Yuan-hao Wu
Yan-qing Wu
Weitong Hu
Hai Su
机构
[1] Nanchang University,The Department of Cardiovascular Medicine, Second Affiliated Hospital and the Second Clinical Medical College
[2] Nanchang University,Queen Mary College of Medical College
来源
Hypertension Research | 2021年 / 44卷
关键词
Blood pressure; Back; Support; Age; Hypertension;
D O I
暂无
中图分类号
学科分类号
摘要
Appropriate body posture is important for accurate blood pressure (BP) measurement. However, the impact of an unsupported back on BP readings is currently controversial. This study included 224 subjects (18–86 years old, 54.5 ± 15.5 years old, 105 males). BP was measured with an oscillometric BP device randomly following one of two protocols for back support conditions: (1) supported–unsupported–supported–unsupported, or (2) unsupported–supported–unsupported–supported. The average of the two systolic BP (SBP) and diastolic BP (DBP) readings in the same position was recorded as the final BP value. The differences in BP between the unsupported and supported back conditions were calculated as delta BP. Moreover, the percentage variation in BP (PV) was calculated with the formula delta BP/BP with an unsupported back. Multivariable regression analysis evaluated the impact of age, sex, hypertension history and supported BP level on PV. The SBP/DBP levels measured with an unsupported back were slightly higher than those when the back was supported (132.7 ± 19.5/79.6 ± 12.9 mmHg vs. 130.3 ± 20.0/78.5 ± 14.3 mmHg), and the delta SBP (2.3 mmHg) was statistically significant. The multivariable regression analysis showed that age was a positive factor but supported SBP level as a negative factor for systolic PV, while age and supported DBP level were positive factors, but hypertension history was a negative factor for diastolic PV. For a group participant, the mean difference in oscillometric SBP/DBP in the unsupported back position was 2.3/1.0 mmHg higher than that in the supported back position.
引用
收藏
页码:528 / 532
页数:4
相关论文
共 50 条
  • [1] Differences in oscillometric blood pressure readings between unsupported and supported back conditions
    Wan, Tai-xuan
    Wu, Yuan-hao
    Wu, Yan-qing
    Hu, Weitong
    Su, Hai
    HYPERTENSION RESEARCH, 2021, 44 (05) : 528 - 532
  • [2] Mean arterial pressure differences between cuff oscillometric and invasive blood pressure
    Picone, Dean S.
    Schultz, Martin G.
    Armstrong, Matthew K.
    Black, J. Andrew
    Dwyer, Nathan
    Roberts-Thomson, Philip
    Weber, Thomas
    Sharman, James E.
    HYPERTENSION RESEARCH, 2025,
  • [3] Automatic blood pressure measurement: the oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements
    Amoore, John N.
    Lemesre, Yann
    Murray, Ian C.
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    JOURNAL OF HYPERTENSION, 2008, 26 (01) : 35 - 43
  • [4] Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure
    Kiers, H. D.
    Hofstra, J. M.
    Wetzels, J. F. M.
    NETHERLANDS JOURNAL OF MEDICINE, 2008, 66 (11): : 474 - 479
  • [5] DIFFERENCES BETWEEN OBSERVERS IN BLOOD-PRESSURE MEASUREMENT WITH AN AUTOMATIC OSCILLOMETRIC RECORDER
    BRUCE, NG
    COOK, DG
    SHAPER, AG
    JOURNAL OF HYPERTENSION, 1990, 8 : S11 - S13
  • [6] UNSUPPORTED ARM - CAUSE OF FALSELY RAISED BLOOD-PRESSURE READINGS
    SILVERBERG, DS
    SHEMESH, E
    IAINA, A
    BRITISH MEDICAL JOURNAL, 1977, 2 (6098): : 1331 - 1331
  • [7] What is the optimal interval between successive home blood pressure readings using an automated oscillometric device?
    Eguchi, Kazuo
    Kuruvilla, Sujith
    Ogedegbe, Gbenga
    Gerin, William
    Schwartz, Joseph E.
    Pickering, Thomas G.
    JOURNAL OF HYPERTENSION, 2009, 27 (06) : 1172 - 1177
  • [8] The effect of back and feet support on oscillometric blood pressure measurements
    Ringrose, Jennifer S.
    Wong, Jonathan
    Yousefi, Farahnaz
    Padwal, Raj
    BLOOD PRESSURE MONITORING, 2017, 22 (04) : 213 - 216
  • [9] Effect of the shapes of the oscillometric pulse amplitude envelopes and their characteristic ratios on the differences between auscultatory and oscillometric blood pressure measurements
    Amoore, John N.
    Vacher, Emilie
    Murray, Ian C.
    Mieke, Stephan
    King, Susan T.
    Smith, Fiona E.
    Murray, Alan
    BLOOD PRESSURE MONITORING, 2007, 12 (05) : 297 - 305
  • [10] HUMAN BLOOD PRESSURE READINGS ARE MORE ACCURATE AND SHOW LESS VARIATION THAN OSCILLOMETRIC DEVICE READINGS
    Grim, C. E.
    Grim, C. M.
    ETHNICITY & DISEASE, 2010, 20 (04) : S33 - S33