Risk factors of gynecological bleeding in female patients with left-ventricular assist device

被引:0
|
作者
Yuji Tominaga
Daisuke Yoshioka
Koichi Toda
Tetsuya Saito
Takuji Kawamura
Noriyuki Kashiyama
Ai Kawamura
Ryohei Matsuura
Takuji Watanabe
Masaki Taira
Shigeru Miyagawa
机构
[1] Osaka University Graduate School of Medicine,Department of Cardiovascular Surgery
来源
关键词
Gynecological bleeding; Left-ventricular assist device; Pseudomenopausal therapy;
D O I
暂无
中图分类号
学科分类号
摘要
Women with implantable left-ventricular assist devices (LVADs) experience gynecological bleeding (GYN-bleeding). However, a few studies have investigated female-specific problems. Therefore, this study aimed to identify the risk factors for adverse GYN-bleeding after LVAD implantation. We retrospectively analyzed 59 women (mean age: 41 ± 15 years) with long-term implantable LVAD support (≥ 6 months) at our institution between 2005 and 2018. The history of GYN-bleeding before implantation was defined as abnormal utero-ovarian bleeding, excessive menstruation, uterine fibroids, and endometrial lesions. GYN-bleeding after implantation was defined as a requirement of emergency outpatient visits and/or hospitalization, blood transfusions, hormonal therapy, and/or surgery. Additionally, risk factors for GYN-bleeding were identified using the Cox regression model. Twenty-four GYN-bleeding cases were seen in 15 patients (two times: five patients, three times: two patients, 0.18 events per patient-year). The 1- and 2-year GYN-bleeding-free rates were 84% and 73%, respectively. Twelve patients (17 events) required RBC ≥ 4 units, and five patients (7 events) required FFP ≥ 4 units. Seven patients required pseudomenopausal treatment after blood transfusion, and four patients required surgical treatment. Fifteen patients with GYN-bleeding after implantation were significantly younger than the remaining 44 patients without GYN-bleeding (34 ± 12 years vs. 43 ± 16 years, P = 0.02). Multivariable risk analysis showed a history of GYN-bleeding before implantation was a significant risk factor (hazard ratio 3.7 [1.2–10.6], P = 0.004). Patients with a history of GYN-bleeding before LVAD implantation have a high risk of developing GYN-bleeding after implantation. We should identify the high-risk population and prepare for the management of GYN-bleeding.
引用
收藏
页码:110 / 116
页数:6
相关论文
共 50 条
  • [31] EARLY EXPERIENCE WITH THE BIOMEDICUS LEFT-VENTRICULAR ASSIST DEVICE
    RAUDKIVI, PJ
    ROBINSON, MC
    NEW ZEALAND MEDICAL JOURNAL, 1991, 104 (914) : 260 - 260
  • [32] Predictive Risk Factors for Postoperative Gastrointestinal Bleeding in Patients Receiving Left Ventricular Assist Devices
    Kabrawala, Anil
    Wells, Brian
    Nagula, Satish
    Bloom, Michelle
    Buscaglia, Jonathan
    Bucobo, Juan Carlos
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2013, 108 : S614 - S615
  • [33] A PERMANENT LEFT-VENTRICULAR ASSIST DEVICE - INVIVO TESTING
    ROSENBERG, G
    SNYDER, AJ
    WEISS, WJ
    CLEARY, TJ
    PIERCE, WS
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 65 - 67
  • [34] Optimum control of the Hemopump as a left-ventricular assist device
    P. He
    J. Bai
    D. D. Xia
    Medical and Biological Engineering and Computing, 2005, 43 : 136 - 141
  • [35] Optimum control of the hemopump as a left-ventricular assist device
    He, P
    Bai, J
    Xia, DD
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (01) : 136 - 141
  • [36] BIOLIZED INTRATHORACIC LEFT-VENTRICULAR ASSIST DEVICE (LVAD)
    HAYASHI, K
    SNOW, J
    WASHIZU, T
    JACOBS, GB
    KIRALY, RJ
    NOSE, Y
    MEDICAL INSTRUMENTATION, 1977, 11 (04): : 202 - 207
  • [37] INVITRO EVALUATION OF AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE
    WITHINGTON, PS
    GRAHAM, TR
    MEIKLE, RJ
    ALLAN, A
    MARRINAN, MT
    LEWIS, CT
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1991, 15 (02) : 68 - 71
  • [38] Preoperative Risk Factors for Left Ventricular Assist Device Related Infection
    Pauwaa, S.
    Blair, C.
    Avula, P.
    Mehta, P.
    Tatooles, A. J.
    Bhat, G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S176 - S176
  • [39] Risk factors for percutaneous left ventricular assist device explant complications
    Schott, Jason P.
    Rusia, Akash
    Lynch, Stephen
    Tawney, Adam
    Mustafa, Syed F.
    Balla, Abdalla K.
    Hanson, Ivan D.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 101 (01) : 147 - 153
  • [40] Risk Factors and Mortality for Sepsis in Left Ventricular Assist Device Recipients
    Joy, P. S.
    Kumar, G.
    Bhama, J. K.
    Cadaret, L. M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S27 - S28