A Cautionary Note: Ceriodaphnia dubia Inter-Laboratory Test Variability

被引:0
|
作者
Laura Pacholski
Peter Chapman
Alexandra Hood
Michelle Peters
机构
[1] Golder Associates Ltd.,
[2] Chapema Environmental Strategies Ltd.,undefined
[3] De Beers Canada Inc.,undefined
关键词
Toxicity; Freshwater; Inter-laboratory; Variability;
D O I
暂无
中图分类号
学科分类号
摘要
An inter-laboratory comparison of the three-brood survival and reproduction Ceriodaphnia dubia toxicity test was conducted involving three toxicity testing laboratories. This comparison was initiated due to sporadic toxicity with this test related to discharge of a mine effluent, which some regulators believed indicated adverse effects in the receiving environment. One mine effluent and two receiving water samples were evaluated. There were no adverse effects on C. dubia survival in any tests. However, sublethal effects on reproduction (i.e., the IC25; the concentration that causes a 25 % inhibitory effect in the measured sublethal endpoint) ranged from 35 % to >100 % among all test treatments. All laboratories were certified for this test and followed established procedures. Dilute mineral water appears to be the best medium for culturing, dilution, and control water. Variability in the C. dubia laboratory toxicity test should not be mistaken for adverse effects in receiving environments.
引用
收藏
页码:53 / 57
页数:4
相关论文
共 50 条
  • [31] Inter-laboratory variability results of porous building materials hygrothermal properties
    Lopez, O.
    Torres, I.
    Guimaraes, A. S.
    Delgado, J. M. P. Q.
    de Freitas, V. P.
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 156 : 412 - 423
  • [32] INTER-LABORATORY VARIABILITY IN PTH MEASUREMENT AND ATTAINMENT OF ANALTIC PERFORMANCE GOALS
    Sarabia, Sam
    Collier, Christine
    Holden, Rachel
    Turner, Mandy
    White, Christine
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33 : 163 - 163
  • [33] ALLOZYMIC VARIABILITY IN TOXICITY-TESTING STRAINS OF CERIODAPHNIA-DUBIA AND IN NATURAL-POPULATIONS OF CERIODAPHNIA
    SNYDER, TP
    SWITZER, KM
    KEEN, RE
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1991, 10 (08) : 1045 - 1049
  • [34] RE-APPRAISAL OF INTER-LABORATORY VARIABILITY IN ANTIEPILEPTIC DRUG DETERMINATIONS
    PIPPENGER, CE
    PARISKUTT, H
    PENRY, JK
    CLINICAL CHEMISTRY, 1978, 24 (06) : 1050 - 1050
  • [35] Inter-Laboratory Variability in Array-Based RNA Quantification Methods
    Wong, Victoria Y.
    Duval, Manuel X.
    GENOMICS INSIGHTS, 2013, 6 : 13 - 24
  • [36] Inter-laboratory consistency and variability in the buccal micronucleus cytome assay depends on biomarker scored and laboratory experience: results from the HUMNxl international inter-laboratory scoring exercise
    Bolognesi, Claudia
    Knasmueller, Siegfried
    Nersesyan, Armen
    Roggieri, Paola
    Ceppi, Marcello
    Bruzzone, Marco
    Blaszczyk, Ewa
    Mielzynska-Svach, Danuta
    Milic, Mirta
    Bonassi, Stefano
    Benedetti, Danieli
    Da Silva, Juliana
    Toledo, Raphael
    Favero Salvadori, Daisy Maria
    Groot de Restrepo, Helena
    Filipic, Metka
    Hercog, Klara
    Aktas, Ayca
    Burgaz, Sema
    Kundi, Michael
    Grummt, Tamara
    Thomas, Philip
    Hor, Maryam
    Escudero-Fung, Maria
    Holland, Nina
    Fenech, Michael
    MUTAGENESIS, 2017, 32 (02) : 257 - 266
  • [37] VARIABILITY IN THE PERFORMANCE OF THE 7-D CERIODAPHNIA-DUBIA SURVIVAL AND REPRODUCTION TEST - AN INTRALABORATORY AND INTERLABORATORY STUDY
    DEGRAEVE, GM
    COONEY, JD
    MARSH, BH
    POLLOCK, TL
    REICHENBACH, NG
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1992, 11 (06) : 851 - 866
  • [38] Inter-laboratory comparison of three earplug fit-test systems
    Byrne, David C.
    Murphy, William J.
    Krieg, Edward F.
    Ghent, Robert M.
    Michael, Kevin L.
    Stefanson, Earl W.
    Ahroon, William A.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (04) : 294 - 305
  • [39] Inter-laboratory test "Identification of Indoor-Fungi" with natural samples
    Gabrio, T
    Seidl, HP
    Szewzyk, R
    Trautmann, C
    Weidner, U
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2005, 65 (09): : 353 - 357
  • [40] INTER-LABORATORY TEST ON ROOM TEMPERATURE COMPRESSIVE STRENGTH OF A DENSE REFRACTORY
    BARON, J
    BASTENAI.F
    LECRIVAI.L
    BULLETIN DE LA SOCIETE FRANCAISE DE CERAMIQUE, 1970, (88): : 53 - &