A cartridge based Point-of-Care device for complete blood count

被引:0
|
作者
Usama Abbasi
Prasanta Chowdhury
Sasikala Subramaniam
Prakhar Jain
Nitin Muthe
Faisal Sheikh
Subham Banerjee
V. Kumaran
机构
[1] MicroX Labs,
[2] Society of Innovation and Development,undefined
[3] Indian Institute of Science,undefined
[4] Department of Chemical Engineering,undefined
[5] Indian Institute of Science,undefined
[6] CSIR-National Aerospace Laboratory,undefined
来源
Scientific Reports | / 9卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
We demonstrate a proprietary lab-on-chip/μ TAS technology platform for a regulatory grade portable instrument for complete blood count (CBC) hematology tests including 3 part differential WBCs, RBCs, platelet and hemoglobin for rapid diagnostics at the point of care in resource-poor settings. Presently, diagnostics based on blood tests are confined to centralized laboratory settings, dependent on large footprint and expensive cytometers or on a microscope, requiring trained laboratory technicians. Consequently, such facilities are not present in rural and semi-urban settings, where there are opportunities and challenges in delivering efficient healthcare infrastructure at an affordable cost in resource-challenged environments. Our proposed design leverages advances in microfluidics and lab-on-chip fabrication techniques to miniaturize the conventional cytometer and bring down the cost significantly. The device can be operated autonomously, without skilled manpower, by primary healthcare professionals in the field and by patients (like glucose self-test devices). The instrument consists of a single-use chip, the size of a credit card, pre-loaded with reagents, in which the sample is loaded, and which is fluidically insulated from the environment. The controller, the size of a toaster, performs the necessary fluid handling and the impedance measurements to deliver the results in minutes.
引用
收藏
相关论文
共 50 条
  • [21] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Walther, Louise Houlberg
    Zegers, Floor
    Nybo, Mads
    Mogensen, Christian Backer
    Christensen, Erika Frischknecht
    Lassen, Annmarie Touborg
    Mikkelsen, Soren
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1679 - 1687
  • [22] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Louise Houlberg Walther
    Floor Zegers
    Mads Nybo
    Christian Backer Mogensen
    Erika Frischknecht Christensen
    Annmarie Touborg Lassen
    Søren Mikkelsen
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1679 - 1687
  • [23] Optoelectronic microfluidic device for point-of-care blood plasma viscosity measurement
    Bakhtiaridoost, Somayyeh
    Musuroi, Cristian
    Volmer, Marius
    Florescu, Monica
    LAB ON A CHIP, 2024, 24 (13) : 3305 - 3314
  • [24] Microfluidic device and system for point-of-care blood coagulation measurement based on electrical impedance sensing
    Ramaswamy, Bharath
    Yeh, Yin-Ting Tim
    Zheng, Si-Yang
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 180 : 21 - 27
  • [25] A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample
    Devi, A. Lakshmi
    Resmi, P. E.
    Pradeep, Aarathi
    Suneesh, P. V.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 287
  • [26] Point-of-care device: a word of caution
    Bhagwat, A. G.
    Taneja, S.
    Singal, N.
    Narang, S.
    ANAESTHESIA AND INTENSIVE CARE, 2009, 37 (01) : 138 - 139
  • [27] Perspectives On Blood-Based Point-Of-Care Diagnostics
    Quig, Karalee
    Wheatley, Elizabeth G.
    O'Hara, Matthew
    OPEN ACCESS EMERGENCY MEDICINE, 2019, 11 : 291 - 296
  • [28] Complete Blood Count as point of care testing QBC STAR™: Preliminary evaluation
    Napolitano, Gavino
    Caracciolo, Alessandra
    Esposito, Sara Apassiti
    Della Malva, Nunzia
    Manenti, Barbara
    Guerra, Giovanni
    Ottomano, Cosimo
    Lippi, Giuseppe
    Buoro, Sabrina
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (05) : 973 - 982
  • [29] Critical Assessment of the Clinical/Technical Work Flow Involved With the Use of Cartridge-Based Point-of-Care Blood Gas Systems
    Creed, Gary Michael
    POINT OF CARE, 2012, 11 (02): : 69 - 72
  • [30] Comparison of a gel column blood typing method and a point-of-care cartridge for Dog Erythrocyte Antigen 1.1
    Blois, Shauna L.
    Richardson, Danielle M.
    Abrams-Ogg, Anthony C. G.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2013, 23 (03) : 340 - 343