Improvement of part-load performance of gas turbine by adjusting compressor inlet air temperature and IGV opening

被引:0
|
作者
Wei Zhu
Xiaodong Ren
Xuesong Li
Chunwei Gu
Zhitan Liu
Zhiyuan Yan
Hongfei Zhu
Tao Zhang
机构
[1] Tsinghua University,Department of Energy and Power Engineering
[2] Guodian Science and Technology Research Institute,undefined
来源
Frontiers in Energy | 2022年 / 16卷
关键词
inlet air temperature; inlet guide vane (IGV) opening; part-load; equilibrium running line; gas turbine (GT) efficiency; surge margin (SM);
D O I
暂无
中图分类号
学科分类号
摘要
A novel adjusting method for improving gas turbine (GT) efficiency and surge margin (SM) under part-load conditions is proposed. This method adopts the inlet air heating technology, which uses the waste heat of low-grade heat source and the inlet guide vane (IGV) opening adjustment. Moreover, the regulation rules of the compressor inlet air temperature and the IGV opening are studied comprehensively to optimize GT performance. A model and calculation method for an equilibrium running line is adopted based on the characteristic curves of the compressor and turbine. The equilibrium running lines calculated through the calculation method involve three part-load conditions and three IGV openings with different inlet air temperatures. The results show that there is an optimal matching relationship between IGV opening and inlet air temperature. For the best GT performance of a given load, the IGV could be adjusted according to inlet air temperature. In addition, inlet air heating has a considerable potential for the improvement of part-load performance of GT due to the increase in compressor efficiency, combustion efficiency, and turbine efficiency as well as turbine inlet temperature, when inlet air temperature is lower than the optimal value with different IGV openings. Further, when the IGV is in a full opening state and an optimal inlet air temperature is achieved by using the inlet air heating technology, GT efficiency and SM can be obviously higher than other IGV openings. The IGV can be left unadjusted, even when the load is as low as 50%. These findings indicate that inlet air heating has a great potential to replace the IGV to regulate load because GT efficiency and SM can be remarkably improved, which is different from the traditional viewpoints.
引用
收藏
页码:1000 / 1016
页数:16
相关论文
共 50 条
  • [21] Part-load performance of a high temperature Kalina cycle
    Modi, Anish
    Andreasen, Jesper Graa
    Kaern, Martin Ryhl
    Haglind, Fredrik
    ENERGY CONVERSION AND MANAGEMENT, 2015, 105 : 453 - 461
  • [22] Benefits of compressor inlet air cooling for gas turbine cogeneration plants
    DeLucia, M
    Lanfranchi, C
    Boggio, V
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 598 - 603
  • [23] Performance Analysis of Axial Flow Compressor and Part Load Consideration in a Gas Turbine Application
    Asli, Majid
    Tousi, Abolghasem M.
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2013, 8 (03): : 476 - 487
  • [24] A part-load performance analysis method for gas turbines based on the stage by stages model of the power turbine
    Deng, Liping
    Wu, Hu
    Xie, Qi'an
    INTERNATIONAL JOURNAL OF TURBO & JET-ENGINES, 2025,
  • [25] Performance Improvement of Simple Gas Turbine Cycle with Vapor Compression Inlet Air Cooling
    Shukla, Anoop Kumar
    Sharma, Achintya
    Sharma, Meeta
    Mishra, Shivam
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (09) : 19172 - 19180
  • [26] Part-Load Performance of a Wet Indirectly Fired Gas Turbine Integrated with an Organic Rankine Cycle Turbogenerator
    Pierobon, Leonardo
    Tuong-Van Nguyen
    Mazzucco, Andrea
    Larsen, Ulrik
    Haglind, Fredrik
    ENERGIES, 2014, 7 (12) : 8294 - 8316
  • [27] Improving part-load performance of combined-cycle gas turbines by optimizing variable geometry control strategy for compressor and power turbine combined adjustment
    Xie, Qi-an
    Wu, Hu
    Deng, Li-ping
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2024, 238 (07) : 1197 - 1212
  • [28] Carbon Capture Performance Assessment Applied to Combined Cycle Gas Turbine Under Part-Load Operation
    Verhaeghe, Antoine
    Dubois, Lionel
    Bricteux, Laurent
    Thomas, Diane
    Blondeau, Julien
    De Paepe, Ward
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2023, 145 (04):
  • [29] CARBON CAPTURE PERFORMANCE ASSESSMENT APPLIED TO COMBINED CYCLE GAS TURBINE UNDER PART-LOAD OPERATION
    Verhaeghe, Antoine
    Dubois, Lionel
    Bricteux, Laurent
    Thomas, Diane
    Blondeau, Julien
    De Paepe, Ward
    PROCEEDINGS OF ASME TURBO EXPO 2022: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2022, VOL 4, 2022,
  • [30] PART-LOAD PERFORMANCE OF GAS TURBINES-PART I: A NOVEL COMPRESSOR MAP GENERATION APPROACH SUITABLE FOR ADAPTIVE SIMULATION
    Tsoutsanis, E.
    Li, Y. G.
    Pilidis, P.
    Newby, M.
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE 2012, 2012, : 733 - +