A biopotential amplifier with dynamic capacitor matching for improved CMRR

被引:0
|
作者
Reza Abdullah
Edgar Sánchez-Sinencio
机构
[1] Texas A&M University,Department of Electrical Engineering
来源
Analog Integrated Circuits and Signal Processing | 2015年 / 82卷
关键词
Biopotential signal; Common mode rejection ratio; Instrumentation amplifier; Fully differential; Common mode gain; Dynamic capacitor matching;
D O I
暂无
中图分类号
学科分类号
摘要
A technique is proposed for improving the common mode rejection ratio (CMRR) of op-amp based instrumentation amplifiers in resistor–capacitor (RC) feedback configurations. This is done by dynamically matching the input and the feedback capacitor pairs. A fully differential biopotential amplifier was designed with the proposed dynamic capacitor matching (DCM) scheme and its performance compared against the conventional case. The experimental results show that the proposed dynamic capacitor matching technique improves CMRR by more than 40 dB over the conventional case. The proposed technique also reduces the power consumption of the biopotential amplifier. The amplifier consumes less power during the ‘OFF’ periods when using DCM and this results in the overall lower power consumption of the amplifier. The quiescent current consumption of the biopotential amplifier is 20 μA with a 1.5 V dual power supply source and a maximum input referred noise of 3 μV.
引用
收藏
页码:47 / 55
页数:8
相关论文
共 50 条
  • [21] Biopotential amplifier for simultaneous operation with biomagnetic instruments
    Virtanen, J
    Parkkonen, L
    Ilmoniemi, RJ
    Pekkonen, E
    Naatanen, R
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (04) : 402 - 408
  • [22] Bandwidth Tunable Amplifier for Recording Biopotential Signals
    Hwang, Sungkil
    Aninakwa, Kofi
    Sonkusale, Sameer
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 662 - 665
  • [23] NOVEL DYNAMIC CMOS AMPLIFIER FOR SWITCHED-CAPACITOR INTEGRATORS
    HOSTICKA, BJ
    ELECTRONICS LETTERS, 1979, 15 (17) : 532 - 533
  • [24] Biopotential amplifier for simultaneous operation with biomagnetic instruments
    J. Virtanen
    L. Parkkonen
    R. J. Ilmoniemi
    E. Pekkonen
    R. Näätänen
    Medical and Biological Engineering and Computing, 1997, 35 : 402 - 408
  • [26] HIGH CMRR CMOS CURRENT OPERATIONAL-AMPLIFIER
    ABOUALLAM, E
    ELMASRY, EI
    ELECTRONICS LETTERS, 1994, 30 (13) : 1042 - 1043
  • [27] Current output stage with improved CMRR
    Centurelli, F
    Pennisi, S
    Trifiletti, A
    ICECS 2003: PROCEEDINGS OF THE 2003 10TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-3, 2003, : 543 - 546
  • [28] Low-Voltage Low-Noise High-CMRR Biopotential Integrated Preamplifier
    Cabrera, Carolina
    Caballero, Renzo
    Costa-Rauschert, Maria Cecilia
    Rossi-Aicardi, Conrado
    Oreggioni, Julian
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2021, 68 (08) : 3232 - 3241
  • [29] Current-feedback operational amplifier with high CMRR
    Tammam, AA
    Haytleh, K
    Hart, B
    Lidgey, FJ
    ELECTRONICS LETTERS, 2003, 39 (21) : 1483 - 1483
  • [30] Capacitively Coupled Multiple Feedback Biopotential Instrumentation Amplifier
    Kim, Hyungseup
    Han, Kwonsang
    Lee, Byeoncheol
    Kim, Jaesung
    Ko, Hyoungho
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 87 - 87