CT-guided vertebroplasty: analysis of technical results, extraosseous cement leakages, and complications in 500 procedures

被引:0
|
作者
Michael Bernhard Pitton
Sascha Herber
Ulrike Koch
Katja Oberholzer
Philip Drees
Christoph Düber
机构
[1] Johannes Gutenberg-University of Mainz,Department of Diagnostic and Interventional Radiology
[2] University Hospital,Department of Orthopedic Surgery
[3] Johannes Gutenberg-University of Mainz,undefined
来源
European Radiology | 2008年 / 18卷
关键词
Osteoporosis; Vertebroplasty; Complications;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to analyze the technical results, the extraosseous cement leakages, and the complications in our first 500 vertebroplasty procedures. Patients with osteoporotic vertebral compression fractures or osteolytic lesions caused by malignant tumors were treated with CT-guided vertebroplasty. The technical results were documented with CT, and the extraosseous cement leakages and periinterventional clinical complications were analyzed as well as secondary fractures during follow-up. Since 2002, 500 vertebroplasty procedures have been performed on 251 patients (82 male, 169 female, age 71.5 ± 9.8 years) suffering from osteoporotic compression fractures (n = 217) and/or malignant tumour infiltration (n = 34). The number of vertebrae treated per patient was 1.96 ± 1.29 (range 1–10); the numbers of interventions per patient and interventions per vertebra were 1.33 ± 0.75 (range 1–6) and 1.01 ± 0.10, respectively. The amount of PMMA cement was 4.5 ± 1.9 ml and decreased during the 5-year period of investigation. The procedure-related 30-day mortality was 0.4% (1 of 251 patients) due to pulmonary embolism in this case. The procedure-related morbidity was 2.8% (7/251), including one acute coronary syndrome beginning 12 h after the procedure and one missing patellar reflex in a patients with a cement leak near the neuroformen because of osteolytic destruction of the respective pedicle. Additionally, one patient developed a medullary conus syndrome after a fall during the night after vertebroplasty, two patients reached an inadequate depth of conscious sedation, and two cases had additional fractures (one pedicle fracture, one rib fracture). The overall CT-based cement leak rate was 55.4% and included leakages predominantly into intervertebral disc spaces (25.2%), epidural vein plexus (16.0%), through the posterior wall (2.6%), into the neuroforamen (1.6%), into paravertebral vessels (7.2%), and combinations of these and others. During follow-up (15.2 ± 13.4 months) the secondary fracture rate was 17.1%, including comparable numbers for vertebrae at adjacent and distant levels. The presence of intradiscal cement leaks was not associated with increased adjacent fracture rates. CT-guided vertebroplasty is safe and effective for treatment of vertebral compression fractures. CT-fluoroscopy provides an excellent control of the posterior vertebral wall. The number of cement leakages alone is not directly associated with clinical complications. However, even small volumes of pulmonary PMMA embolism might be responsible for the fatal outcome in cases with underlying cardiopulmonary insufficiency.
引用
收藏
页码:2568 / 2578
页数:10
相关论文
共 50 条
  • [21] CT-guided lumbar sympathectomy: Results and analysis of factors influencing the outcome
    Heindel, W
    Ernst, S
    Manshausen, G
    Gawenda, M
    Siemens, P
    Krahe, T
    Walter, M
    Lackner, K
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (04) : 319 - 323
  • [22] Accuracy of CT-guided transthoracic needle biopsy of lung lesions: Results of 612 consecutive procedures
    Ricardi, U.
    Priola, A. M.
    Priola, S. M.
    Novello, S.
    Cataldi, A.
    Crida, B.
    Scagliotti, G. V.
    Fava, C.
    JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (18)
  • [23] Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions
    de Lima, Cristiano Dias
    Nunes, Rodolfo Acatauassu
    Saito, Eduardo Haruo
    Higa, Claudio
    Fernando Cardona, Zanier Jose
    dos Santos, Denise Barbosa
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2011, 37 (02) : 209 - 216
  • [24] CT fluoroscopy-guided vertebral augmentation with a radiofrequency-induced, high-viscosity bone cement (StabiliT®): technical results and polymethylmethacrylate leakages in 25 patients
    Christoph Gregor Trumm
    Tobias F. Jakobs
    Robert Stahl
    Torleif A. Sandner
    Philipp M. Paprottka
    Maximilian F. Reiser
    Christoph J. Zech
    Ralf-Thorsten Hoffmann
    Skeletal Radiology, 2013, 42 : 113 - 120
  • [25] CT fluoroscopy-guided vertebral augmentation with a radiofrequency-induced, high-viscosity bone cement (StabiliTA®): technical results and polymethylmethacrylate leakages in 25 patients
    Trumm, Christoph Gregor
    Jakobs, Tobias F.
    Stahl, Robert
    Sandner, Torleif A.
    Paprottka, Philipp M.
    Reiser, Maximilian F.
    Zech, Christoph J.
    Hoffmann, Ralf-Thorsten
    SKELETAL RADIOLOGY, 2013, 42 (01) : 113 - 120
  • [26] Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions
    Mills, M.
    Choi, J.
    El-Haddad, G.
    Sweeney, J.
    Biebel, B.
    Robinson, L.
    Antonia, S.
    Kumar, A.
    Kis, B.
    CLINICAL RADIOLOGY, 2017, 72 (12) : 1038 - 1046
  • [27] CT Fluoroscopy-Guided Percutaneous Fiducial Marker Placement for CyberKnife Stereotactic Radiosurgery: Technical Results and Complications in 222 Consecutive Procedures
    Trumm, Christoph G.
    Haeussbler, Sophia M.
    Muacevic, Alexander
    Stahl, Robert
    Stintzing, Sebastian
    Paprottka, Philipp M.
    Strobl, Frederik
    Jakobs, Tobias F.
    Reiser, Maximilian F.
    Hoffmann, Ralf-Thorsten
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (05) : 760 - 768
  • [28] Computer-assisted navigation system for interventional CT-guided procedures: Results of phantom and clinical studies
    Meier-Meitinger, M.
    Nagel, M.
    Kalender, W.
    Bautz, W. A.
    Baum, U.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (04): : 310 - 317
  • [29] Percutaneous CT-guided fine-needle aspiration of pulmonary lesions: Results and complications in 409 patients
    Laspas, F.
    Roussakis, A.
    Efthimiadou, R.
    Papaioannou, D.
    Papadopoulos, S.
    Andreou, J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2008, 52 (05) : 458 - 462
  • [30] Measurement Analysis of Ice Ball Size during CT-Guided Cryoablation Procedures for Better Prediction of Final Ice Ball Size and Avoidance of Complications
    Al-Assam, Hayder
    Botchu, Rajesh
    Azzopardi, Christine
    Stevenson, Jonathan Daniel
    James, Steven L. L.
    Patel, Anish
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2023, 33 (03): : 321 - 326