High-resolution continuum source atomic absorption spectrometry: a review of current applications

被引:0
|
作者
V. V. Eskina
V. B. Baranovskaya
Yu. A. Karpov
D. G. Filatova
机构
[1] National University of Science and Technology “MISIS”,N. S. Kurnakov Institute of General and Inorganic Chemistry
[2] Federal State Research and Design Institute of Rare-Metal Industry “Giredmet” JSC,Department of Chemistry
[3] Russian Academy of Sciences,undefined
[4] M. V. Lomonosov Moscow State University,undefined
来源
Russian Chemical Bulletin | 2020年 / 69卷
关键词
high-resolution continuum source atomic absorption spectrometry; high-resolution continuum source graphite furnace atomic absorption spectrometry; high-resolution continuum source flame atomic absorption spectrometry; solid sampling high-resolution continuum source atomic absorption spectrometry; simultaneous determination; sequential determination; analysis of suspensions;
D O I
暂无
中图分类号
学科分类号
摘要
Atomic absorption spectrometry (AAS) is one of the most widely used and available methods for analysis of substances and materials. It allows one to determine about 70 elements from the periodic table and is characterized by rapidity, high accuracy and sensitivity, as well as simplicity of analytical techniques. A feature of AAS is simultaneous determination of only one element due to the use of a measurement design with a line source (hollow-cathode lamps, high-frequency electrodeless lamps, optical quantum generators, etc.). To make AAS more competitive, the first commercially available continuum source atomic absorption spectrometer was designed in 2004. Unique analytical capabilities of the new instruments found application first of all in the analysis of food, pharmaceuticals, waste and drinking water, oil and petrochemicals, biological objects, etc. This review covers publications on the application of continuum source AAS in analytical chemistry and provides a development outlook of the method.
引用
收藏
页码:1 / 16
页数:15
相关论文
共 50 条
  • [41] Determination of silicon and aluminum in silicon carbide nanocrystals by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Dravecz, Gabriella
    Bencs, Laszlo
    Beke, David
    Gali, Adam
    TALANTA, 2016, 147 : 271 - 275
  • [42] Direct determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
    Husakova, Lenka
    Sidova, Tereza
    Ibrahimova, Lucie
    Svizelova, Monika
    Mikysek, Tomas
    ANALYTICAL METHODS, 2019, 11 (09) : 1254 - 1263
  • [43] Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry
    da Silva, AF
    Borges, DLG
    Lepri, FG
    Welz, B
    Curtius, AJ
    Heitmann, U
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) : 1835 - 1841
  • [44] Graphite tubes with small internal diameters tailored for high-resolution continuum source graphite furnace atomic absorption spectrometry
    Huang, Mao Dong
    Becker-Ross, Helmut
    Okruss, Michael
    Geisler, Sebastian
    Florek, Stefan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (06) : 982 - 988
  • [45] Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry
    Alessandra Furtado da Silva
    Daniel L. G. Borges
    Fábio Grandis Lepri
    Bernhard Welz
    Adilson J. Curtius
    Uwe Heitmann
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1835 - 1841
  • [46] Evaluation of Lines of Phosphorus and Potassium by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Liquid Fertilizer Analysis
    Ferreira, Roberta Borges
    Oliveira, Silvana Ruella
    Franzini, Vanessa Pezza
    Virgilio, Alex
    Raposo Junior, Jorge Luiz
    Gomes Neto, Jose Anchieta
    ATOMIC SPECTROSCOPY, 2011, 32 (02) : 56 - 61
  • [47] HIGH-RESOLUTION CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY IN AN AIR-ACETYLENE FLAME WITH PHOTODIODE ARRAY DETECTION
    JONES, BT
    MIGNARDI, MA
    SMITH, BW
    WINEFORDNER, JD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) : 647 - 651
  • [48] HIGH-RESOLUTION CONTINUUM-SOURCE ATOMIC-ABSORPTION SPECTROMETRY IN AN INDUCTIVELY COUPLED PLASMA WITH PHOTODIODE ARRAY DETECTION
    MIGNARDI, MA
    JONES, BT
    SMITH, BW
    WINEFORDNER, JD
    ANALYTICA CHIMICA ACTA, 1989, 227 (02) : 331 - 342
  • [49] High-resolution continuum source electrothermal atomic absorption spectrometry: Linearization of the calibration curves within a broad concentration range
    Katskov, Dmitri
    Hlongwane, Miranda
    Heitmann, Uwe
    Florek, Stefan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 14 - 23
  • [50] Unusual calibration curves observed for iron using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Welz, Bernhard
    dos Santos, Lisia M. G.
    Araujo, Rennan G. O.
    Jacob, Silvana do C.
    Vale, Maria Goreti R.
    Okruss, Michael
    Becker-Ross, Helmut
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (03) : 258 - 262