Peculiarities of hydrogen ion extraction from pulsed plasma plumes

被引:0
|
作者
A. N. Didenko
V. I. Rashchikov
V. I. Ryzhkov
A. E. Shikanov
机构
[1] Moscow Engineering Physics Institute (State University),
[2] Dukhov All-Russia Research Institute of Automatics,undefined
来源
Technical Physics Letters | 2011年 / 37卷
关键词
Technical Physic Letter; Elec Trons; Plasma Plume; Plasma Boundary; Emission Current Density;
D O I
暂无
中图分类号
学科分类号
摘要
A compact system for neutron generation based on a diode with the anode representing a lasergenerated plasma plume has been studied. The process of deuteron extraction from the anode is described using a mechanism related to the Langmuir oscillations at the plasma-vacuum interface, which provides good agreement with experimental data.
引用
收藏
页码:1021 / 1023
页数:2
相关论文
共 50 条
  • [31] Hydrogen Production from Methane Through Pulsed DC Plasma
    Nasser N. Morgan
    Mansour ElSabbagh
    Plasma Chemistry and Plasma Processing, 2017, 37 : 1375 - 1392
  • [32] Development of a laser ion source with pulsed ion extraction
    Koizumi, M
    Osa, A
    Sekine, T
    Kubota, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 126 (1-4): : 100 - 104
  • [33] Ion extraction from carbon shunting arc plasma
    Takaki, K
    Mukaigawa, S
    Fujiwara, T
    Kumagai, M
    Yukimura, K
    APPLIED PHYSICS LETTERS, 2003, 82 (16) : 2583 - 2585
  • [34] ION EXTRACTION FROM A PLASMA THROUGH A CONICAL ORIFICE
    KUMAR, SVK
    SIDDAGANGAPPA, MC
    VENKATASUBRAMANIAN, VS
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (12): : 1306 - 1307
  • [35] Hybrid (particle-fluid) modeling of pulsed plasma thruster plumes
    Gatsonis, NA
    Yin, XM
    JOURNAL OF PROPULSION AND POWER, 2001, 17 (05) : 945 - 958
  • [36] Numerical analysis of electronegative plasma in the extraction region of negative hydrogen ion sources
    Kuppel, S.
    Matsushita, D.
    Hatayama, A.
    Bacal, M.
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (01)
  • [37] Depth of Influence on the Plasma by Beam Extraction in a Negative Hydrogen Ion Source for NBI
    Geng, Shaofei
    Tsumori, Katsuyoshi
    Nakano, Haruhisa
    Kisaki, Masashi
    Ikeda, Katsunori
    Osakabe, Masaki
    Nagaoka, Ken-ichi
    Takeiri, Yasuhiko
    Shibuya, Masayuki
    Kaneko, Osamu
    PLASMA AND FUSION RESEARCH, 2016, 11 (11):
  • [38] STABILITY MEASURES IN A PULSED HYDROGEN PLASMA
    GIGOSOS, MA
    MAR, S
    ANNALES DE PHYSIQUE, 1986, 11 (03) : 193 - 194
  • [39] EXTRACTION OF NEGATIVE HYDROGEN IONS FROM A DUOPLASMATRON ION SOURCE
    COLLINS, LE
    GOBBETT, RH
    NUCLEAR INSTRUMENTS & METHODS, 1965, 35 (02): : 277 - &
  • [40] Comparison between leaky and pulsed modes of ion extraction from an electron beam ion trap
    Hu, Zhimin
    Ishiguro, Yusuke
    Watanabe, Hirofumi
    Ohtani, Shunsuke
    Nakamura, Nobuyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 298 : 96 - 99