Magnetic field effect analysis of electromagnetic transducer for implantable hearing device

被引:1
|
作者
Kim M.W. [1 ]
Shin D.H. [2 ]
Lee J.W. [2 ]
Lim H.G. [2 ]
Seong K.W. [3 ]
Kim M.N. [4 ]
Cho J.H. [2 ]
Lee J.H. [3 ]
机构
[1] Defense Agency for Technology and Quality, 52-8, 28-gil, Dongweon-ro, Suseong-gu, Daegu
[2] School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 1370 Sankyuk-dong, Buk-gu, Daegu
[3] Department of Biomedical Engineering, Kyungpook National University Hospital, 130 DongDuk-Ro, Jung-gu, Daegu
[4] Department of Biomedical Engineering, School of Medicine, Kyungpook National University, 680 Gukchaebosang-ro, Jung-gu, Daegu
关键词
DFMT; FEA; FMT; IMEHD; Torque analysis;
D O I
10.1007/s13534-013-0111-1
中图分类号
学科分类号
摘要
Purpose: Electromagnetic transducers are widely used for implantable hearing devices because they can be miniaturized, and their vibration intensity is suitable for middle ear stimulation. There are two types of electromagnetic transducers: a floating mass transducer (FMT) and differential floating mass transducer (DFMT). Both transducers have a permanent magnet and a coil to generate electromagnetic force. However, FMTs have disadvantage in that unwanted vibration can be generated in a static magnetic field, such as in MRI. Methods: In this paper, a magnetic field effect analysis of two types of electromagnetic transducers was performed. The torque that is generated by the static magnetic field has been calculated through finite element analysis (FEA). Then, the effects of the static magnetic field in both transducers were compared through an experiment based on the simulated results. Results: The results of FEA and the experiment show that the torque of the DFMT are smaller than that of the FMT in a static magnetic field. Conclusions: Therefore, it is expected that the DFMT is a suitable transducer for implantable hearing devices. © 2013 Korean Society of Medical and Biological Engineering and Springer.
引用
收藏
页码:258 / 262
页数:4
相关论文
共 50 条
  • [1] Effect of magnetic resonance imaging on a new electromagnetic implantable middle ear hearing device
    Hunyadi, S
    Werning, JW
    Lewin, JS
    Maniglia, AJ
    AMERICAN JOURNAL OF OTOLOGY, 1997, 18 (03): : 328 - 331
  • [2] Fabrication and optimal design of differential electromagnetic transducer for implantable middle ear hearing device
    Kim, Min-Kyu
    Park, Il-Yong
    Song, Byung-Scop
    Cho, Jin-Ho
    Biosensors and Bioelectronics, 2006, 21 (11) : 2170 - 2175
  • [3] Fabrication and optimal design of differential electromagnetic transducer for implantable middle ear hearing device
    Kim, MK
    Park, IY
    Song, BS
    Cho, JH
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (11): : 2170 - 2175
  • [4] Design considerations for a contactless electromagnetic transducer for implantable hearing aids
    Kompis, M
    Kuhn, C
    Affolter, M
    Brugger, U
    Häusler, R
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 3173 - 3176
  • [5] Design of differential electromagnetic transducer for implantable middle ear hearing device using finite element method
    Kim, Min-Kyu
    Yoon, Young-Ho
    Park, Il-Yong
    Cho, Jin-Ho
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 130 : 234 - 240
  • [6] ELECTROMAGNETIC SEMI-IMPLANTABLE HEARING DEVICE - AN UPDATE
    KARTUSH, JM
    MCGEE, TM
    GRAHAM, MD
    KULICK, KC
    LAROUERE, MJ
    HEIDE, J
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1991, 104 (01) : 150 - 150
  • [7] Computer assisted optimization of an electromagnetic transducer design for implantable hearing aids
    Stieger, C
    Wäckerlin, D
    Bernhard, H
    Stahel, A
    Kompis, M
    Häusler, R
    Burger, E
    COMPUTERS IN BIOLOGY AND MEDICINE, 2004, 34 (02) : 141 - 152
  • [8] Fully implantable hearing device with transducer on the round window as a treatment of mixed hearing loss
    Tringali, Stephane
    Pergola, Nick
    Berger, Paul
    Dubreuil, Christian
    AURIS NASUS LARYNX, 2009, 36 (03) : 353 - 358
  • [9] Effect of static bias magnetic field on electromagnetic acoustic transducer sensitivity
    Institute for NDT and Mechatronics Engineering, Beihang University, Beijing 100191, China
    Jixie Gongcheng Xuebao, 10 (1-7):
  • [10] Human studies of a piezoelectric transducer and a microphone for a totally implantable electronic hearing device
    Zenner, HP
    Leysieffer, H
    Maassen, M
    Lehner, R
    Lenarz, T
    Baumann, J
    Keiner, S
    Plinkert, PK
    McElveen, JT
    AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (02): : 196 - 204