Multivariate statistical monitoring of subway indoor air quality using dynamic concurrent partial least squares

被引:0
|
作者
Hongbin Liu
Chong Yang
Mingzhi Huang
ChangKyoo Yoo
机构
[1] Nanjing Forestry University,Co
[2] Kyung Hee University,Innovation Center of Efficient Processing and Utilization of Forest Resources
[3] South China Normal University,Department of Environmental Science and Engineering, College of Engineering
关键词
Concurrent partial least squares; Dynamic process monitoring; Fault detection; Indoor air quality; Subway systems;
D O I
暂无
中图分类号
学科分类号
摘要
To maintain the health level of indoor air quality (IAQ) in subway stations, the data-driven multivariate statistical method concurrent partial least squares (CPLS) has been successfully applied for output-relevant and input-relevant sensor faults detection. To cope with the dynamic problem of IAQ data, the augmented matrices are applied to CPLS (DCPLS) to achieve the better performance. DCPLS method simultaneously decomposes the input and output data spaces into five subspaces for comprehensive monitoring: a joint input-output subspace, an output principal subspace, an output-residual subspace, an input-principal subspace, and an input-residual subspace. Results of using the underground IAQ data in a subway station demonstrate that the monitoring capability of DCPLS is superior than those of PLS and CPLS. More specifically, the fault detection rates of the bias of PM10 and PM2.5 using DCPLS can be improved by approximately 13% and 15%, respectively, in comparison with those of CPLS.
引用
收藏
页码:4159 / 4169
页数:10
相关论文
共 50 条
  • [21] Multivariate calibration of spectrophotometric data using a partial least squares with data fusion
    Gao, Ling
    Ren, Shouxin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2010, 76 (3-4) : 363 - 368
  • [22] Modeling of subway indoor air quality using Gaussian process regression
    Liu, Hongbin
    Yang, Chong
    Huang, Mingzhi
    Wang, Dongsheng
    Yoo, ChangKyoo
    JOURNAL OF HAZARDOUS MATERIALS, 2018, 359 : 266 - 273
  • [23] Quality-Relevant Fault Monitoring Based on Locality-Preserving Partial Least-Squares Statistical Models
    Wang, J.
    Zhong, B.
    Zhou, J. L.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2017, 56 (24) : 7009 - 7020
  • [24] Quality-Relevant Fault Monitoring Based on Locally Linear Embedding Enhanced Partial Least Squares Statistical Models
    Zhou, Jinglin
    Gao, Wei
    Zhang, Shunli
    Wang, Jing
    Zhu, Haijiang
    2017 6TH DATA DRIVEN CONTROL AND LEARNING SYSTEMS (DDCLS), 2017, : 259 - 264
  • [25] Quality-Related Statistical Process Monitoring Method Based on Global and Local Partial Least-Squares Projection
    Zhong, Bin
    Wang, Jing
    Zhou, Jinglin
    Wu, Haiyan
    Jin, Qibing
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (06) : 1609 - 1622
  • [26] Online nonlinear process monitoring using kernel partial least squares
    Hu Y.
    Wang L.
    Ma H.
    Shi H.
    Huagong Xuebao/CIESC Journal, 2011, 62 (09): : 2555 - 2561
  • [27] Multivariate calibration for machine health monitoring: kernel partial least squares combined with variable selection
    Hyun-Woo Cho
    The International Journal of Advanced Manufacturing Technology, 2010, 48 : 691 - 699
  • [28] Multivariate calibration for machine health monitoring: kernel partial least squares combined with variable selection
    Cho, Hyun-Woo
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2010, 48 (5-8): : 691 - 699
  • [29] Voice Conversion Using Dynamic Kernel Partial Least Squares Regression
    Helander, Elina
    Silen, Hanna
    Virtanen, Tuomas
    Gabbouj, Moncef
    IEEE TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2012, 20 (03): : 806 - 817
  • [30] Assessing Air Quality Using Multivariate Statistical Approaches
    Pham, Nguyen Quoc
    Nguyen, Giao Thanh
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2024, 10 (02): : 521 - 533