Geometry of thoracolumbar vertebral endplates of the human spine

被引:0
|
作者
Hong Chen
Dianming Jiang
Yunsheng Ou
Jian Zhong
Fajin Lv
机构
[1] First Affiliated Hospital of Chongqing Medical University,Department of Orthopedics
[2] Chongqing Medical University,Department of Radiology, First Affiliated Hospital
来源
European Spine Journal | 2011年 / 20卷
关键词
Geometry; Thoracolumbar spine; Vertebral endplate; Vertebral body replacement;
D O I
暂无
中图分类号
学科分类号
摘要
Novel and better vertebral body replacement constructs are always desired by surgeons. Endplate geometry is crucial for the design of those implants, but current literature on that topic is very scarce. The authors present a morphometric study of thoracolumbar vertebral endplates, the goal of which was to analyze the geometry of endplates from T10 inferior to L3 superior by employing data from CT scans, as well as to verify the reliability of data derived from the CT measurement. Reformatted CT scans of 83 individuals were analyzed and sagittal concave angle, location of concave region, sagittal diameter of endplate, coronal concave angle, as well as transverse diameter of endplate were measured in midsagittal plane and specified coronal plane. The data of CT and cadaveric measurements of ten cadaveric specimens were also compared. Age and gender did not influence sagittal concave angle, location of concave region, and coronal concave angle significantly (P > 0.05). No significant difference has been revealed among each endplate for sagittal concave angle (range 162.5°–163.9°) and location of concave region (range 42.5–44.2%), either. Ranging between 170.9° and 175.7°, coronal concave angle was constantly larger in superior endplate than in inferior one. The sagittal and transverse endplate diameters of females were significantly smaller than those of males (P < 0.05), being about 88% of the latter one. The mean difference between CT and cadaveric measurements was small (Cronbach alpha > 0.8). Those morphologic parameters, especially the concavity of endplates, should be taken into consideration when designing novel vertebral body replacement constructs. CT measurement data could be used to calculate most suitable geometric parameters of those implants.
引用
收藏
页码:1814 / 1820
页数:6
相关论文
共 50 条
  • [21] Biomechanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine
    Pflugmacher, R
    Schleicher, P
    Schaefer, J
    Scholz, M
    Ludwig, K
    Khodadadyan-Klostermann, C
    Haas, NP
    Kandziora, F
    SPINE, 2004, 29 (13) : 1413 - 1419
  • [22] A newly designed vertebral replacement implant to reconstruct the thoracolumbar spine anteriorly
    Vanderschot, P
    Schepers, E
    Vanschoonwinkel, A
    Broos, P
    ACTA CHIRURGICA BELGICA, 2002, 102 (01) : 37 - 45
  • [23] Morphology of the lumbar vertebral endplates
    Hall, LT
    Esses, SI
    Noble, PC
    Kamaric, E
    SPINE, 1998, 23 (14) : 1517 - 1522
  • [24] Vertebral endplates, the anatomically discrete structures of the vertebral column
    Singh, Vishram
    Murlimanju, B., V
    Vadgaonkar, Rajanigandha
    JOURNAL OF THE ANATOMICAL SOCIETY OF INDIA, 2022, 71 (03) : 167 - 168
  • [25] AN ANATOMICAL COMPARISON OF THE HUMAN AND BOVINE THORACOLUMBAR SPINE
    COTTERILL, PC
    KOSTUIK, JP
    DANGELO, G
    FERNIE, GR
    MAKI, BE
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (03) : 298 - 303
  • [26] Finite element modeling of the human thoracolumbar spine
    Liebschner, MAK
    Kopperdahl, DL
    Rosenberg, WS
    Keaveny, TM
    SPINE, 2003, 28 (06) : 559 - 565
  • [27] Intervertebral disc degeneration can predispose to anterior vertebral fractures in the thoracolumbar spine
    Adams, Michael A.
    Pollintine, Phillip
    Tobias, Jon H.
    Wakley, Glenn K.
    Dolan, Patricia
    JOURNAL OF BONE AND MINERAL RESEARCH, 2006, 21 (09) : 1409 - 1416
  • [28] CARTILAGE ENDPLATES OF HUMAN VERTEBRAL COLUMN (SOME CONSIDERATIONS OF POSTNATAL DEVELOPMENT)
    DONISCH, EW
    TRAPP, W
    ANATOMICAL RECORD, 1971, 169 (04): : 705 - +
  • [29] Percutaneous vertebroplasty with hydroxyapatite for the treatment of osteoporotic vertebral burst fracture of thoracolumbar spine
    Urayama, S
    STATE OF ART FOR MINIMALLY INVASIVE SPINE SURGERY, 2005, : 43 - 61
  • [30] ANTERIOR VERTEBRAL RECONSTRUCTION OF THE THORACOLUMBAR SPINE USING THE HALL-DWYER INSTRUMENTATION
    ONIMUS, M
    LAURAIN, JM
    FIORE, N
    FERRE, B
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1989, 75 (08): : 558 - 568