Flux calculation in LSNAA using an 241Am-Be source

被引:0
|
作者
R. Khelifi
P. Bode
A. Amokrane
机构
[1] Université Saad DAHLAB,Department de Physique
[2] Interfaculty Reactor Institute,undefined
[3] Faculté de Physique,undefined
关键词
Neutron Source; Flux Distribution; Neutron Spectrum; Thermal Flux; Flux Calculation;
D O I
暂无
中图分类号
学科分类号
摘要
The CITATION code based on neutron diffusion theory is used for flux calculation inside voluminous sample in prompt gamma activation analysis with an isotopic neutron source (241Am-Be). The code used the specific parameters related to energy spectrum source, irradiation system materials (shielding, reflector, etc.), geometry and elemental composition of the sample. The flux distribution (thermal and fast) was calculated on three-dimensional geometry for the system: source, air, and polyethylene and water cylindrical sample of 125 liters. The thermal flux was calculated in series of points inside the sample, and agreed with the results obtained by measurements with good statistical uncertainty. The maximum thermal flux was measured at distance of 4.1 cm and calculated at 4.3 cm by the CITATION code. Beyond a depth of 7.2 cm, the ratio of thermal flux to fast flux increases up to twice and allows us the optimization of the detection system in the scope of in-situ PGNAA.
引用
收藏
页码:639 / 642
页数:3
相关论文
共 50 条
  • [41] STANDARDISATION OF WATER-MODERATED 241Am-Be NEUTRON SOURCE USING DE PANGHER NEUTRON LONG COUNTER: EXPERIMENTAL AND MONTE CARLO MODELLING
    Ghodke, Shobha
    Kumari, Sujatha
    Singh, Yashoda
    Sathian, V.
    Mahant, A. K.
    Sharma, D. N.
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (03) : 358 - 365
  • [42] Monte Carlo optimization of sample dimensions of an 241Am-Be source-based PGNAA setup for water rejects analysis
    Idiri, Z.
    Mazrou, H.
    Beddek, S.
    Amokrane, A.
    Azbouche, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (01): : 279 - 288
  • [43] Calculation of response matrix of CaSO4:Dy based neutron dosimeter using Monte Carlo code FLUKA and measurement of 241Am-Be spectra
    Chatterjee, S.
    Bakshi, A. K.
    Tripathy, S. P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (17-18): : 2825 - 2830
  • [44] Replacement of Bonner spheres with polyethylene cylinders for the unfolding of an 241Am-Be neutron energy spectrum
    Ghal-Eh, N.
    Kalaei, M.
    Mohammadi, A.
    Vega-Carrillo, H. R.
    APPLIED RADIATION AND ISOTOPES, 2017, 128 : 292 - 296
  • [45] Evaluation of the calibration factors of neutron dose rate meters in a 241Am-Be neutron field
    Thiem Ngoc Le
    Sy Minh Tuan Hoang
    Quynh Ngoc Nguyen
    Hoai-Nam Tran
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (09)
  • [46] Design and optimization of a source (reflector/shielding) performance test system based on (241Am-Be)-paraffin thermal neutron irradiation device
    Elsheikh, Nassreldeen A. A.
    Elagib, I.
    Alsewaidan, H.
    Kassim, Hamoud A.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (05)
  • [47] Installation and measurement capacity of 3 x 592 GBq 241Am-Be neutron irradiation cell
    Bulut, Serdar
    Celenk, I.
    Artan, S.
    KERNTECHNIK, 2013, 78 (06) : 519 - 525
  • [48] Spectra and dose with ANN of 252Cf, 241Am-Be, and 239Pu-Be
    Rene Vega-Carrillo, Hector
    Martinez-Blanco, M. R.
    Martin Hernandez-Davila, Victor
    Manuel Ortiz-Rodriguez, Jose
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 281 (03) : 615 - 618
  • [49] A neutron energy spectrum study of 241Am-Be based on improved Gravel and PSO algorithms
    Yang, Lu-ying
    Wan, Hai
    Zhang, Ying-Chao
    Jiang, Xiao-fei
    RADIATION MEASUREMENTS, 2025, 181
  • [50] Performance comparison of 2.8 MeV and 241Am-Be neutrons based moisture measurement setups
    Abdelmonem, M. S.
    Naqvi, A. A.
    Al-Ghamdi, Hanan
    Al-Misned, Ghada
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 274 (01) : 131 - 137